A Novel Contingency-Aware Primary Frequency Control for Power Grids With High CIG-Penetration

被引:2
|
作者
Khamisov, Oleg Olegovich [1 ]
Ali, Mazhar [2 ]
Sayfutdinov, Timur [3 ]
Jiang, Yan [4 ]
Terzija, Vladimir [5 ]
Vorobev, Petr [6 ]
机构
[1] Skolkovo Inst Sci & Technol, Ctr Energy Sci & Technol, Moscow 121205, Russia
[2] Univ Cent Florida, Dept Elect & Comp Engn, Orlnado, FL 32816 USA
[3] Xian Jiaotong Liverpool Univ, Sch Adv Technol, Suzhou 215000, Peoples R China
[4] Univ Washington, Dept Elect & Comp Engn, Seattle, WA 98195 USA
[5] Newcastle Univ Newcastle, Sch Engn, Merz Court E4 41, Newcastle Upon Tyne NE1 7RU, England
[6] Nanyang Technol Univ, Nanyang 639798, Singapore
关键词
Frequency control; Generators; Power system dynamics; Frequency estimation; Power system stability; Vehicle dynamics; Optimization; Contingency-aware control; converter-interfaced generation; primary frequency control; CHALLENGES; NETWORKS; FEEDBACK; MODEL;
D O I
10.1109/TPWRS.2023.3339596
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The ever-growing trend of Converter-Interfaced Generation (CIG) integration in electrical power grids has led to a tremendous concern about systems' inertia, stability, and frequency regulation effectiveness. During contingencies, like the loss of a large generator, the primary frequency control is deployed to compensate for the frequency drop. However, as CIG penetration grows, traditional primary frequency control becomes less effective in mitigating significant post-contingency frequency deviations. To address this problem, we introduce a novel control framework that fully utilizes the proportional primary frequency control concept manifested in the contingency-aware control discontinuity. The proposed framework collects information about the disturbance and redistributes control gains according to the pre-calculated optimal strategy employing dynamic properties of both synchronous generation and CIG. It incorporates a novel frequency security assessment using frequency majorant functions, providing a conservative low boundary estimate of the frequency nadir. Numerical studies demonstrate that this proposed control strategy reduces nadir deviation by 49% and shortens the transient period by 30%. Furthermore, we illustrate the optimization of droop control gains considering CIG characteristics, such as location and inertia, to enhance system stability by allowing CIGs to perform primary frequency control functions from synchronous generators.
引用
收藏
页码:5792 / 5805
页数:14
相关论文
共 34 条
  • [21] Impact of Frequency-Watt Control on the Dynamics of a High DER Penetration Power System
    Pattabiraman, Dinesh
    Tan, Jin
    Gevorgian, Vahan
    Hoke, Andy
    Antonio, Chris
    Arakawa, Dean
    2018 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2018,
  • [22] High Wind Power Penetration in Isolated Power Systems-Assessment of Wind Inertial and Primary Frequency Responses
    Wang, Ye
    Delille, Gauthier
    Bayem, Herman
    Guillaud, Xavier
    Francois, Bruno
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2013, 28 (03) : 2412 - 2420
  • [23] Frequency response models and control in smart power systems with high penetration of renewable energy sources
    Alhelou, Hassan Haes
    Golshan, Mohamad Esmail Hamedani
    Siano, Pierluigi
    COMPUTERS & ELECTRICAL ENGINEERING, 2021, 96
  • [24] Frequency Control for a High Penetration Wind-Based Energy Storage System in the Power Network
    Rahman, Md Jahidur
    Tafticht, Tahar
    Doumbia, Mamadou Lamine
    2020 IEEE ELECTRIC POWER AND ENERGY CONFERENCE (EPEC), 2020,
  • [25] Decentralized Cooperative Active Power Control for Small-Scale Grids with High Renewable Penetration through VSC-HVDC
    So, Jihun
    Shin, Hyun
    Thai Nguyen Tran
    Choi, Yeong-Jun
    SUSTAINABILITY, 2022, 14 (15)
  • [26] Supplementary Frequency Control in a High-penetration Real Power System by Renewables Using SMES Application
    Magdy, Gaber
    Nour, Morsy
    Shabib, G.
    Elbaset, Adel A.
    Mitani, Yasunori
    JOURNAL OF ELECTRICAL SYSTEMS, 2019, 15 (04) : 526 - 538
  • [27] Dynamic load frequency control for high-penetration wind power considering wind turbine fatigue load
    Wang, Xiaodong
    Wang, Yingwei
    Liu, Yingming
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2020, 117
  • [28] Virtual Inertia Control Application to Enhance Frequency Stability of Interconnected Power Systems with High Renewable Energy Penetration
    Kerdphol, Thongchart
    Rahman, Fathin Saifur
    Mitani, Yasunori
    ENERGIES, 2018, 11 (04)
  • [29] Power Stability and Frequency Control Techniques of DG for a High Penetration Wind-Based Energy Storage System Using Integral-Derivative Controller
    Rahman, Md Jahidur
    Tafticht, Tahar
    Doumbia, Mamadou Lamine
    IEEE CANADIAN JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING, 2022, 45 (03): : 232 - 241
  • [30] Adaptive Power Point Tracking Control of PV System for Primary Frequency Regulation of AC Microgrid With High PV Integration
    Li, Zhongwen
    Cheng, Zhiping
    Si, Jikai
    Zhang, Shuyuan
    Dong, Lianghui
    Li, Shuhui
    Gao, Yixiang
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2021, 36 (04) : 3129 - 3141