Usefulness of Impulse Oscillometry in Predicting the Severity of Bronchiectasis

被引:0
作者
Choi, Ji Soo [1 ]
Kwak, Se Hyun [1 ]
Kim, Min Chul [1 ]
Seol, Chang Hwan [1 ]
Heo, Seok-Jae [2 ]
Kim, Sung Ryeol [1 ]
Lee, Eun Hye [1 ]
机构
[1] Yonsei Univ, Yongin Severance Hosp, Dept Internal Med, Div Pulmonol Allergy & Crit Care Med,Coll Med, 363 Dongbaekjukjeon Daero, Yongin 16995, South Korea
[2] Yonsei Univ, Coll Med, Dept Biomed Syst Informat, Div Biostat, Seoul, South Korea
关键词
Bronchiectasis; Impulse Oscillometry; Disease Severity; FORCED OSCILLATION TECHNIQUE; LUNG-FUNCTION; FIBROSIS BRONCHIECTASIS; 4-YEAR-OLD CHILDREN; PREVALENCE; INDEX; US;
D O I
10.4046/trd.2023.0160
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: Bronchiectasis is a chronic respiratory disease that leads to airway inflammation, destruction, and airflow limitation, which reflects its severity. Impulse oscillometry (IOS) is a non-invasive method that uses sound waves to estimate lung function and airway resistance. The aim of this study was to assess the usefulness of IOS in predicting the severity of bronchiectasis. Methods: We retrospectively reviewed the IOS parameters and clinical characteristics in 145 patients diagnosed with bronchiectasis between March 2020 and May 2021. Disease severity was evaluated using the FACED score, and patients were divided into mild and moderate/severe groups. Results: Forty-four patients (30.3%) were in the moderate/severe group, and 101 (69.7%) were in the mild group. Patients with moderate/severe bronchiectasis had a higher airway resistance at 5 Hz (R5), a higher difference between the resistance at 5 and 20 Hz (R5-R20), a higher resonant frequency (Fres), and a higher area of reactance (AX) than patients with mild bronchiectasis. R5 >= 0.43, resistance at 20 Hz (R20) >= 0.234, R5-R20 >= 28.3, AX >= 1.02, reactance at 5 Hz (X5) <=-0.238, and Fres >= 20.88 revealed significant univariable relationships with bronchiectasis severity (p<0.05). Among these, only X5 <=-0.238 exhibited a significant multivariable relationship with bronchiectasis severity (p=0.039). The receiver operating characteristic curve for predicting moderate-to-severe bronchiectasis of FACED score based on IOS parameters exhibited an area under the curve of 0.809. Conclusion: The IOS assessed by the disease severity of FACED score can effectively reflect airway resistance and elasticity in bronchiectasis patients and serve as valuable
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
[41]   The Bronchiectasis Severity Index and FACED score for assessment of the severity of bronchiectasis [J].
Costa, J. C. ;
Machado, J. N. ;
Ferreira, C. ;
Gama, J. ;
Rodrigues, C. .
PULMONOLOGY, 2018, 24 (03) :149-154
[42]   Impulse oscillometry in preschool children and association with body mass index [J].
Kalhoff, Hermann ;
Breidenbach, Renate ;
Smith, Hans-Juergen ;
Marek, Wolfgang .
RESPIROLOGY, 2011, 16 (01) :174-179
[43]   Impulse oscillometry: Gathering speed in the assessment of preschool lung function [J].
Guilbert, Theresa W. ;
Mcdowell, Karen M. .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2024, 154 (01) :82-83
[44]   New Classifications of COPD Severity Based on Impulse Oscillometry: A SAIO Grade Base on ECOPD Cohort in China [J].
Lu, Lifei ;
Wan, Qi ;
Tang, Gaoying ;
Wu, Fan ;
Deng, Zhishan ;
Peng, Jieqi ;
Dai, Cuiqiong ;
Zhou, Kunning ;
Wu, Xiaohui ;
Yu, Shuqing ;
Huang, Yongqing ;
Yang, Changli ;
Chen, Shengtang ;
Ran, Pixin ;
Zhou, Yumin .
ARCHIVOS DE BRONCONEUMOLOGIA, 2025, 61 (06) :334-340
[45]   Impulse oscillometry: The state-of-art for lung function testing [J].
Desiraju, Koundinya ;
Agrawal, Anurag .
LUNG INDIA, 2016, 33 (04) :410-416
[46]   Impulse oscillometry in patients with pulmonary arterial hypertension: an exploratory study [J].
Bo, Helena Jannuzzi Villas ;
Paschoal, Ilma Aparecida ;
Pereira, Monica Corso .
CLINICS, 2024, 79
[47]   Potentiality of impulse oscillometry to evaluate bronchodilator reversibility in untreated adult patients with newly diagnosed asthma [J].
Hsiao, Yi-Han ;
Lin, Yu-Jung ;
Jeng, Tien-Hsin ;
Su, Kang-Cheng ;
Ko, Hsin-Kuo ;
Yang, Sheau-Ning ;
Perng, Diahn-Warng ;
Kou, Yu Ru .
JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2022, 85 (08) :859-865
[48]   Vitamin D and disease severity in bronchiectasis [J].
Ferri, S. ;
Crimi, C. ;
Heffler, E. ;
Campisi, R. ;
Noto, A. ;
Crimi, N. .
RESPIRATORY MEDICINE, 2019, 148 :1-5
[49]   Vocal Cord Dysfunction as Demonstrated by Impulse Oscillometry [J].
Komarow, Hirsh D. ;
Young, Michael ;
Nelson, Celeste ;
Metcalfe, Dean D. .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY-IN PRACTICE, 2013, 1 (04) :387-+
[50]   Evaluation of children with cystic fibrosis by impulse oscillometry when stable and at exacerbation [J].
Sakarya, Ayfer ;
Uyan, Zeynep S. ;
Baydemir, Canan ;
Anik, Yonca ;
Erdem, Ela ;
Gokdemir, Yasemin ;
Karadag, Bulent ;
Karakoc, Fazilet ;
Ersu, Refika .
PEDIATRIC PULMONOLOGY, 2016, 51 (11) :1151-1158