Usefulness of Impulse Oscillometry in Predicting the Severity of Bronchiectasis

被引:0
|
作者
Choi, Ji Soo [1 ]
Kwak, Se Hyun [1 ]
Kim, Min Chul [1 ]
Seol, Chang Hwan [1 ]
Heo, Seok-Jae [2 ]
Kim, Sung Ryeol [1 ]
Lee, Eun Hye [1 ]
机构
[1] Yonsei Univ, Yongin Severance Hosp, Dept Internal Med, Div Pulmonol Allergy & Crit Care Med,Coll Med, 363 Dongbaekjukjeon Daero, Yongin 16995, South Korea
[2] Yonsei Univ, Coll Med, Dept Biomed Syst Informat, Div Biostat, Seoul, South Korea
关键词
Bronchiectasis; Impulse Oscillometry; Disease Severity; FORCED OSCILLATION TECHNIQUE; LUNG-FUNCTION; FIBROSIS BRONCHIECTASIS; 4-YEAR-OLD CHILDREN; PREVALENCE; INDEX; US;
D O I
10.4046/trd.2023.0160
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: Bronchiectasis is a chronic respiratory disease that leads to airway inflammation, destruction, and airflow limitation, which reflects its severity. Impulse oscillometry (IOS) is a non-invasive method that uses sound waves to estimate lung function and airway resistance. The aim of this study was to assess the usefulness of IOS in predicting the severity of bronchiectasis. Methods: We retrospectively reviewed the IOS parameters and clinical characteristics in 145 patients diagnosed with bronchiectasis between March 2020 and May 2021. Disease severity was evaluated using the FACED score, and patients were divided into mild and moderate/severe groups. Results: Forty-four patients (30.3%) were in the moderate/severe group, and 101 (69.7%) were in the mild group. Patients with moderate/severe bronchiectasis had a higher airway resistance at 5 Hz (R5), a higher difference between the resistance at 5 and 20 Hz (R5-R20), a higher resonant frequency (Fres), and a higher area of reactance (AX) than patients with mild bronchiectasis. R5 >= 0.43, resistance at 20 Hz (R20) >= 0.234, R5-R20 >= 28.3, AX >= 1.02, reactance at 5 Hz (X5) <=-0.238, and Fres >= 20.88 revealed significant univariable relationships with bronchiectasis severity (p<0.05). Among these, only X5 <=-0.238 exhibited a significant multivariable relationship with bronchiectasis severity (p=0.039). The receiver operating characteristic curve for predicting moderate-to-severe bronchiectasis of FACED score based on IOS parameters exhibited an area under the curve of 0.809. Conclusion: The IOS assessed by the disease severity of FACED score can effectively reflect airway resistance and elasticity in bronchiectasis patients and serve as valuable
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
  • [1] The Role of Impulse Oscillometry in Evaluating Disease Severity and Predicting the Airway Reversibility in Patients With Bronchiectasis
    Tan, Cuiyan
    Ma, Donghai
    Wang, Kongqiu
    Tu, Changli
    Chen, Meizhu
    Zheng, Xiaobin
    Liang, Yingjian
    Huang, Yiying
    Wang, Zhenguo
    Wu, Jian
    Huang, Jin
    Liu, Jing
    FRONTIERS IN MEDICINE, 2022, 9
  • [2] Impulse Oscillometry in Adults with Bronchiectasis
    Guan, Wei-jie
    Gao, Yong-hua
    Xu, Gang
    Lin, Zhi-ya
    Tang, Yan
    Li, Hui-min
    Lin, Zhi-min
    Zheng, Jin-ping
    Chen, Rong-chang
    Zhong, Nan-shan
    ANNALS OF THE AMERICAN THORACIC SOCIETY, 2015, 12 (05) : 657 - 665
  • [3] Impulse Oscillometry and Spirometry Small-Airway Parameters in Mild to Moderate Bronchiectasis
    Guan, Wei-jie
    Yuan, Jing-jing
    Gao, Yong-hua
    Li, Hui-min
    Zheng, Jin-ping
    Chen, Rong-chang
    Zhong, Nan-shan
    RESPIRATORY CARE, 2016, 61 (11) : 1513 - 1522
  • [4] Impulse oscillometry usefulness in small-airway dysfunction in asthmatics and its utility in asthma control
    Sharshar, Ragia S.
    EGYPTIAN JOURNAL OF BRONCHOLOGY, 2019, 13 (04) : 452 - 458
  • [5] Prediction of severity of obstructive sleep apnea by awake impulse oscillometry
    Schild, Georg
    Schreiber, Richard
    Lux, Anke
    Stegemann-Koniszewski, Sabine
    Luecke, Eva
    Schreiber, Jens
    SLEEP MEDICINE, 2025, 126 : 218 - 221
  • [6] Impulse oscillometry, an aid or a substitute?
    Elkolaly, Reham M.
    Ganna, Salwa A.
    Nada, Doaa W.
    Elnaggar, Mohammed H.
    EGYPTIAN JOURNAL OF BRONCHOLOGY, 2019, 13 (03) : 416 - 423
  • [7] Impulse oscillometry
    Desai, Unnati
    Joshi, Jyotsna M.
    ADVANCES IN RESPIRATORY MEDICINE, 2019, 87 (04) : 235 - 238
  • [8] Values of Impulse Oscillometry in Healthy Mexican Children and Adolescents
    Gochicoa-Rangel, Laura
    Torre-Bouscoulet, Luis
    Martinez-Briseno, David
    Rodriguez-Moreno, Luis
    Cantu-Gonzalez, Gabriela
    Vargas, Mario H.
    RESPIRATORY CARE, 2015, 60 (01) : 119 - 127
  • [9] Current place of impulse oscillometry in the assessment of pulmonary diseases
    Bednarek, Marcin
    Grabicki, Marcin
    Piorunek, Tomasz
    Batura-Gabryel, Halina
    RESPIRATORY MEDICINE, 2020, 170
  • [10] Use of Impulse Oscillometry System in Assessment of Asthma Severity for Preschool Children
    Shin, Youn Ho
    Yoon, Jung Won
    Choi, Sun Hee
    Baek, Ji Hyeon
    Kim, Hyeung Yoon
    Jee, Hye Mi
    Yum, Hye Yung
    Han, Man Yong
    JOURNAL OF ASTHMA, 2013, 50 (02) : 198 - 203