Non-invasive temperature monitoring in fixed-bed reactors by electrical capacitance tomography

被引:1
作者
Weiss, Michael [1 ,2 ]
Fischerauer, Alice [1 ]
Jess, Andreas [2 ]
Fischerauer, Gerhard [1 ]
机构
[1] Univ Bayreuth, Ctr Energy Technol, Chair Measurement & Control Syst, Bayreuth, Germany
[2] Univ Bayreuth, Chair Chem Engn, Ctr Energy Technol, Bayreuth, Germany
关键词
ECT; electrical capacitance tomography; fixed-bed reactor; temperature profile; non-invasive; temperature monitoring;
D O I
10.1088/1361-6501/ad5224
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Knowledge of the temperature distribution in fixed-bed reactors is of great importance for process control and optimization in many processes of the chemical industry. The state of the art is defined by invasive measuring methods for temperature measurement in such reactors. However, all invasive methods influence both the structure of the fixed-bed and the flow conditions and thus falsify the measurement results compared to real undisturbed conditions in a fixed-bed, above all with regard to the radial temperature profile. In addition, the temperature distribution in the entire reactor is usually derived from a few discrete measuring points based on a model, which sometimes results in large deviations from reality. In this article, electrical capacitance tomography (ECT) is explored as an alternative, non-invasive measurement method to monitor the temperature distribution inside fixed-bed reactors. The method exploits the temperature dependence of the effective bulk permittivity of the reactor filling. By way of an example, this dependence has been investigated in this work for two different hydrogenation catalysts. A temperature-resistant ECT sensor has been designed to perform measurements under the influence of temperature. The investigations show that, with the aid of ECT, it is possible to detect relative temperature changes in the region of interest with the materials examined.
引用
收藏
页数:14
相关论文
共 29 条
[1]   Fixed bed reactors [J].
Andrigo, P ;
Bagatin, R ;
Pagani, G .
CATALYSIS TODAY, 1999, 52 (2-3) :197-221
[2]   Flame Imaging in Meso-scalle Porous Media Burner Using Electrical Capacitance Tomography [J].
Chen Qi ;
Liu Shi .
CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2012, 20 (02) :329-336
[3]   Imaging nylon polymerisation processes by applying electrical tomography [J].
Dyakowski, T ;
York, T ;
Mikos, M ;
Vlaev, D ;
Mann, R ;
Follows, G ;
Boxman, A ;
Wilson, M .
CHEMICAL ENGINEERING JOURNAL, 2000, 77 (1-2) :105-109
[4]   Visualisation of gas-oil two-phase flows in pressurised pipes using electrical capacitance tomography [J].
Gamio, JC ;
Castro, J ;
Rivera, L ;
Alamilla, J ;
Garcia-Nocetti, F ;
Aguilar, L .
FLOW MEASUREMENT AND INSTRUMENTATION, 2005, 16 (2-3) :129-134
[5]   Noninvasive real-time 2D imaging of temperature distribution during the plastic pellet cooling process by using electrical capacitance tomography [J].
Hirose, Yusuke ;
Sapkota, Achyut ;
Sugawara, Michiko ;
Takei, Masahiro .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2016, 27 (01)
[6]  
Ho J., 2009, Characterization of High Temperature Polymer Thin Films for Power Conditioning Capacitors
[7]   Estimation of Combustion Temperature Field From the Electrical Admittivity Distribution Obtained by Electrical Tomography [J].
Hu, Die ;
Tian, Yu ;
Chang, Liuyong ;
Sun, Shijie ;
Sun, Jiangtao ;
Cao, Zhang ;
Xu, Lijun .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (09) :6271-6280
[8]   High-temperature electrical capacitance tomography for gas-solid fluidised beds [J].
Huang, Kai ;
Meng, Shuanghe ;
Guo, Qiang ;
Ye, Mao ;
Shen, Jingjing ;
Zhang, Tao ;
Yang, Wuqiang ;
Liu, Zhongmin .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2018, 29 (10)
[9]  
Industrial Tomography Systems Ltd, 2023, M3c-electrical capacitance tomography-products-ITS
[10]  
Jess A., 2020, Chemical Technology: From Principles to Products, V2