A nonparametric measure of contrast in x-ray images

被引:0
|
作者
Anton, M. [1 ,2 ]
Reginatto, M. [1 ,2 ]
Schopphoven, S. [3 ]
Jaoude, C. Abou [3 ]
Maeder, U. [4 ]
Fiebich, M. [4 ]
Mauter, F. [1 ,2 ,5 ]
Sechopoulos, I [5 ,6 ]
van Engen, R. [6 ]
机构
[1] Phys Tech Bundesanstalt, Bundesanstalt, Germany
[2] Phys Tech Bundesanstalt, Berlin, Germany
[3] Reference Ctr Mammog Screening Southwest Germany, Giessen, Germany
[4] Univ Appl Sci, Inst Med Phys & Radiat Protect, Giessen, Germany
[5] Radboud Univ Nijmegen, Med Ctr, Nijmegen, Netherlands
[6] LRCB Dutch Expert Ctr Screening, Nijmegen, Netherlands
关键词
quality assurance; contrast; grey value distance; nonparametric statistics; x-ray diagnostics; PATIENT-SPECIFIC QUANTIFICATION; NO-REFERENCE; QUALITY ASSESSMENT; AUTOMATED TECHNIQUE; PARAMETER; SELECTION;
D O I
10.1088/1361-6560/ad6119
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. We propose a nonparametric figure of merit, the contrast equivalent distance CED, to measure contrast directly from clinical images. Approach. A relative brightness distance delta is calculated by making use of the order statistic of the pixel values. By multiplying delta with the grey value range R, the mean brightness distance MBD is obtained. From the MBD, the CED and the distance-to-noise ratio DNR can be derived. The latter is the ratio of the MBD and a previously suggested nonparametric measure tau for the noise. Since the order statistic is independent of the spatial arrangement of the pixel values, the measures can be obtained directly from clinical images. We apply the new measures to mammography images of an anthropomorphic phantom and of a phantom with a step wedge as well as to CT images of a head phantom. Main results. For low-noise images of a step wedge, the MBD is equivalent to the conventional grey value distance. While this measure permits the evaluation of clinical images, it is sensitive to noise. Therefore, noise has to be quantified at the same time. When the ratio sigma/tau of the noise standard deviation sigma to tau is available, validity limits for the CED as a measure of contrast can be established. The new figures of merit can be calculated for entire images as well as on regions of interest (ROI) with an edge length not smaller than 32 px. Significance. The new figures of merit are suited to quantify the quality of clinical images without relying on the assumption of a linear, shift-invariant system. They can be used for any kind of greyscale image, provided the ratio sigma/tau can be estimated. This will hopefully help to achieve the optimisation of image quality vs dose required by radioprotection laws.
引用
收藏
页数:19
相关论文
共 50 条
  • [41] Quality Assessment Algorithm of X-Ray Images in Overall Girth Welds Based on Deep Neural Network
    Gao, Boxuan
    Zhao, Hong
    Miao, Xingyuan
    Wu, Tingting
    JOURNAL OF PIPELINE SYSTEMS ENGINEERING AND PRACTICE, 2023, 14 (01)
  • [42] Comparison of a segmentation algorithm to six expert imagiologists in detecting pulmonary contours on X-ray CT images
    Ferreira, C
    Santos, BS
    Silva, JS
    Silva, A
    MEDICAL IMAGING 2003: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2003, 5034 : 347 - 358
  • [43] Biological applications of X-ray microprobes
    Paunesku, Tatjana
    Vogt, Stefan
    Irving, Thomas C.
    Lai, Barry
    Barrea, Raul A.
    Maser, Joerg
    Woloschak, Gayle E.
    INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2009, 85 (08) : 710 - 713
  • [44] Fusion of Gamma-rays and portable X-ray fluorescence spectral data to measure extractable potassium in soils
    Nawar, Said
    Richard, Florence
    Kassim, Anuar M.
    Tekin, Yucel
    Mouazen, Abdul M.
    SOIL & TILLAGE RESEARCH, 2022, 223
  • [45] A Procedure for the Characterization of Monocapillary X-Ray Lenses as Condensers for Full-Field Transmission X-Ray Microscopes
    Sun, Xuepeng
    Shao, Shangkun
    Li, Huiquan
    Zhang, Xiaoyun
    Yuan, Tianyu
    Tao, Fen
    Sun, Tianxi
    FRONTIERS IN PHYSICS, 2022, 10
  • [46] Unsupervised Learning with Generative Adversarial Network for Automatic Tire Defect Detection from X-ray Images
    Wang, Yilin
    Zhang, Yulong
    Zheng, Li
    Yin, Liedong
    Chen, Jinshui
    Lu, Jiangang
    SENSORS, 2021, 21 (20)
  • [47] Two dimensional x-ray phase imaging using single grating interferometer with embedded x-ray targets
    Morimoto, Naoki
    Fujino, Sho
    Yamazaki, Amane
    Ito, Yasuhiro
    Hosoi, Takuji
    Watanabe, Heiji
    Shimura, Takayoshi
    OPTICS EXPRESS, 2015, 23 (13): : 16582 - 16588
  • [48] The high energy X-ray probe (HEX-P): bringing the cosmic X-ray background into focus
    Civano, F.
    Zhao, X.
    Boorman, P. G.
    Marchesi, S.
    Ananna, T.
    Creech, S.
    Chen, C. -t.
    Hickox, R. C.
    Stern, D.
    Madsen, K.
    Garcia, J. A.
    Silver, R.
    Aird, J.
    Alexander, D. M.
    Balokovic, M.
    Brandt, W. N.
    Buchner, J.
    Gandhi, P.
    Kammoun, E.
    Lamassa, S.
    Lanzuisi, G.
    Merloni, A.
    Moretti, A.
    Nandra, K.
    Nardini, E.
    Pizzetti, A.
    Puccetti, S.
    Pfeifle, R. W.
    Ricci, C.
    Spiga, D.
    Torres-Alba, N.
    FRONTIERS IN ASTRONOMY AND SPACE SCIENCES, 2024, 11
  • [49] Nonparametric Classification of Satellite Images
    Dinuls, Romans
    Mednieks, Ints
    ICOMS 2018: 2018 INTERNATIONAL CONFERENCE ON MATHEMATICS AND STATISTICS, 2018, : 64 - 68
  • [50] Cross and local optimal avoidance of RIME algorithm: A segmentation study for COVID-19 X-ray images
    Yuan, Chong
    Zhao, Dong
    Heidari, Ali Asghar
    Liu, Lei
    Chen, Yi
    Liang, Guoxi
    DISPLAYS, 2024, 83