A nonparametric measure of contrast in x-ray images

被引:0
|
作者
Anton, M. [1 ,2 ]
Reginatto, M. [1 ,2 ]
Schopphoven, S. [3 ]
Jaoude, C. Abou [3 ]
Maeder, U. [4 ]
Fiebich, M. [4 ]
Mauter, F. [1 ,2 ,5 ]
Sechopoulos, I [5 ,6 ]
van Engen, R. [6 ]
机构
[1] Phys Tech Bundesanstalt, Bundesanstalt, Germany
[2] Phys Tech Bundesanstalt, Berlin, Germany
[3] Reference Ctr Mammog Screening Southwest Germany, Giessen, Germany
[4] Univ Appl Sci, Inst Med Phys & Radiat Protect, Giessen, Germany
[5] Radboud Univ Nijmegen, Med Ctr, Nijmegen, Netherlands
[6] LRCB Dutch Expert Ctr Screening, Nijmegen, Netherlands
关键词
quality assurance; contrast; grey value distance; nonparametric statistics; x-ray diagnostics; PATIENT-SPECIFIC QUANTIFICATION; NO-REFERENCE; QUALITY ASSESSMENT; AUTOMATED TECHNIQUE; PARAMETER; SELECTION;
D O I
10.1088/1361-6560/ad6119
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. We propose a nonparametric figure of merit, the contrast equivalent distance CED, to measure contrast directly from clinical images. Approach. A relative brightness distance delta is calculated by making use of the order statistic of the pixel values. By multiplying delta with the grey value range R, the mean brightness distance MBD is obtained. From the MBD, the CED and the distance-to-noise ratio DNR can be derived. The latter is the ratio of the MBD and a previously suggested nonparametric measure tau for the noise. Since the order statistic is independent of the spatial arrangement of the pixel values, the measures can be obtained directly from clinical images. We apply the new measures to mammography images of an anthropomorphic phantom and of a phantom with a step wedge as well as to CT images of a head phantom. Main results. For low-noise images of a step wedge, the MBD is equivalent to the conventional grey value distance. While this measure permits the evaluation of clinical images, it is sensitive to noise. Therefore, noise has to be quantified at the same time. When the ratio sigma/tau of the noise standard deviation sigma to tau is available, validity limits for the CED as a measure of contrast can be established. The new figures of merit can be calculated for entire images as well as on regions of interest (ROI) with an edge length not smaller than 32 px. Significance. The new figures of merit are suited to quantify the quality of clinical images without relying on the assumption of a linear, shift-invariant system. They can be used for any kind of greyscale image, provided the ratio sigma/tau can be estimated. This will hopefully help to achieve the optimisation of image quality vs dose required by radioprotection laws.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] A nonparametric measure of noise in x-ray diagnostic images-mammography
    Anton, M.
    Maeder, U.
    Schopphoven, S.
    Reginatto, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (04)
  • [2] Radiographic Techniques, Contrast, and Noise in X-Ray Imaging
    Huda, Walter
    Abrahams, R. Brad
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (02) : W126 - W131
  • [3] A Contrast Calibration Protocol for X-ray Speckle Visibility Spectroscopy
    Sun, Yanwen
    Esposito, Vincent
    Hart, Philip Adam
    Hansson, Conny
    Li, Haoyuan
    Nakahara, Kazutaka
    MacArthur, James Paton
    Nelson, Silke
    Sato, Takahiro
    Song, Sanghoon
    Sun, Peihao
    Fuoss, Paul
    Sutton, Mark
    Zhu, Diling
    APPLIED SCIENCES-BASEL, 2021, 11 (21):
  • [4] X-ray Moire deflectometry using synthetic reference images
    Stutman, Dan
    Valdivia, Maria Pia
    Finkenthal, Michael
    APPLIED OPTICS, 2015, 54 (19) : 5956 - 5961
  • [5] Memory Effects in Subjective Quality Assessment of X-Ray Images
    Landre, Victor
    Pedersen, Marius
    Waaler, Dag
    IMAGE ANALYSIS, SCIA 2017, PT II, 2017, 10270 : 314 - 325
  • [6] The distribution of the contrast of X-ray standing waves fields in different media
    Bruecher, Martin
    von Bohlen, Alex
    Hergenroeder, Roland
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2012, 71-72 : 62 - 69
  • [7] A numerical study of resolution and contrast in soft X-ray contact microscopy
    Wang, Y
    Jacobsen, C
    JOURNAL OF MICROSCOPY-OXFORD, 1998, 191 : 159 - 169
  • [8] Ray Tracing Simulation of Images of Dislocations and Inclusions on X-Ray Topographs of GaAs Epitaxial Wafers
    Peng, Hongyu
    Ailihumaer, Tuerxun
    Raghothamachar, Balaji
    Dudley, Michael
    JOURNAL OF ELECTRONIC MATERIALS, 2020, 49 (06) : 3472 - 3480
  • [9] Use of oversampling to quantify phase effects in X-ray images of straight fibers
    Palma-Alejandro, K. D.
    Murrieta, T.
    Brandan, M. E.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 701 : 201 - 207
  • [10] Quality Assurance of Chest X-ray Images with a Combination of Deep Learning Methods
    Oura, Daisuke
    Sato, Shinpe
    Honma, Yuto
    Kuwajima, Shiho
    Sugimori, Hiroyuki
    APPLIED SCIENCES-BASEL, 2023, 13 (04):