Seismic fragility analysis of prefabricated self-centering frame structure

被引:6
作者
Yan, Xueyuan [1 ]
Shi, Shen [1 ]
Wang, Fengxuan [1 ]
Mao, Huimin [2 ]
机构
[1] Fuzhou Univ, Coll Civil Engn, Fuzhou 350116, Peoples R China
[2] Fujian Univ Technol, Sch Ecol Environm & Urban Construct, Fuzhou 350118, Peoples R China
基金
中国国家自然科学基金;
关键词
Incremental dynamic analysis; OpenSees; Phenomenological joint; Prefabricated self -centering frame; Seismic fragility analysis; CFDST COLUMN; CONCRETE; BEHAVIOR; JOINT;
D O I
10.1016/j.jcsr.2024.108843
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The seismic fragility of prefabricated self-centering frame structures composed of self-centering joints is investigated for reference in their seismic design and application. In this paper, a new design of the concrete-filled double steel tubular column-RC beam joint with self-centering capability and friction energy dissipation was proposed. The joint was modeled with ABAQUS and OpenSees, and hysteretic simulation was carried out to verify the reasonableness and accuracy of the OpenSees phenomenological model. Based on the OpenSees platform, a one-bay, six-story prefabricated self-centering frame structure was modeled, and seismic fragility analysis based on the incremental dynamic analysis was performed, in which seismic fragility curves were obtained according to the probabilistic demand analysis model. The results indicated a high coincidence in hysteretic curves between the ABAQUS model and the OpenSees phenomenological model, which showed favorable self-centering and energy dissipation performance of the joint proposed in this paper. Based on FEMA 356, three kinds of performance points were defined, i.e., "Immediate Occupancy" (IO), "Life Safety" (LS), and "Collapse Prevention" (CP). The prefabricated self-centering frame in this paper tended to exceed the IO, where the stiffness and strength of the structure was susceptible to damage. However, the failure probability at the LS performance level remained low, with only 5% and 37% failure probability under moderate and rare earthquakes, respectively. The structure achieved a collapse margin ratio of 4.28, which indicated a high collapse resistance in it.
引用
收藏
页数:13
相关论文
共 45 条
[1]  
Ahmed A.D., 2022, Turk. J. Eng, V6, P16, DOI [10.31127/tuje.749730, DOI 10.31127/TUJE.749730]
[2]  
[Anonymous], 2009, Quantification of building seismic performance factors (FEMA P695)
[3]  
[Anonymous], 2010, Code for Seismic Design of Buildings
[4]  
[Anonymous], 2000, Prestandard and Commentary for the Seismic Rehabilitation of Buildings
[5]   Seismic fragility investigation of hybrid structures BRBF with eccentric-configuration and self-centering frame [J].
Azandariani, Mojtaba Gorji ;
Gholami, Mohammad .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 196
[6]   Probabilistic sensitivity analysis of multi-span highway bridges [J].
Bayat, M. ;
Daneshjoo, F. ;
Nistico, N. .
STEEL AND COMPOSITE STRUCTURES, 2015, 19 (01) :237-262
[7]   Seismic Fragility Analysis of Base-Isolated Building Frames Excited by Near- and Far-Field Earthquakes [J].
Bhandari, M. ;
Bharti, S. D. ;
Shrimali, M. K. ;
Datta, T. K. .
JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2019, 33 (03)
[8]  
Castanheira D.S., 2021, ce/papers, V4, P764
[9]   Self-centering energy dissipative bracing system for the seismic resistance of structures: Development and validation [J].
Christopoulos, C. ;
Tremblay, R. ;
Kim, H. -J. ;
Lacerte, M. .
JOURNAL OF STRUCTURAL ENGINEERING, 2008, 134 (01) :96-107
[10]   Seismic response of self-centring hysteretic SDOF systems [J].
Christopoulos, C ;
Filiatrault, A ;
Folz, B .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2002, 31 (05) :1131-1150