Investigation of the linear accelerator low dose rate mode for pulsed low-dose-rate radiotherapy delivery

被引:0
作者
Abdelgawad, Mahmoud H. [1 ,2 ]
Eldib, Ahmed A. [2 ]
Elsayed, Tamer M. [1 ]
Ma, C. M. Charlie [2 ]
机构
[1] Al Azhar Univ, Fac Sci, Phys Dept, Cairo, Egypt
[2] Temple Univ Hlth Syst, Fox Chase Canc Ctr, 333 Cottman Ave, Philadelphia, PA 19111 USA
关键词
pulsed low dose rate; VMAT; machine dose rate; effective dose rate; MODULATED RADIATION-THERAPY; HYPER-RADIOSENSITIVITY; RETREATMENT STRATEGY; NECK-CANCER; RECURRENT; REIRRADIATION; LUNG; HEAD; HYPERSENSITIVITY; GLIOBLASTOMA;
D O I
10.1088/2057-1976/ad73dd
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose. Pulsed volumetric modulated arc therapy (VMAT) was proposed as an advanced treatment that combines the biological benefits of pulsed low dose rate (PLDR) and the dosimetric benefits of the intensity-modulated beams. In our conventional pulsed VMAT technique, a daily fractional dose of 200 cGy is delivered in 10 arcs with 3 min intervals between the arcs. In this study, we are testing the feasibility of pulsed VMAT that omits the need to split into ten arcs and excludes any beam-off gaps. Methods. The study was conducted using computed tomographic images of 24 patients previously treated at our institution with the conventional PLDR technique. Our newly installed Elekta machine has a low dose rate option on the order of 25 MU min-1. PLDR requires an effective dose rate of 6.7 cGy min-1 with attention being paid to the maximum dose received within any point within the target not to exceed 13 cGy min-1. The quality of treatment plans was judged based on dose-volume histograms, isodose distribution, dose conformality to the target, and target dose homogeneity. The dose delivery accuracy was assessed by measurements using the MatriXX Evolution 2D array system. Results. All cases were normalized to cover 95% of the target volume with 100% of the prescription dose. The average conformity index was 1.03 +/- 0.08 while the average homogeneity index was 1.05 +/- 0.02. The maximum reported dose rate at any point within the target was 10.44 cGy min-1. The mean dose rate for all pulsed VMAT plans was 6.88 +/- 0.1 cGy min-1. All cases passed our gamma analysis with an average passing rate of 99.00% +/- 0.48%. Conclusion. The study showed the applicability of planning pulsed VMAT using Eclipse and its successful delivery on our Elekta linac. Pulsed VMAT using the machine's low dose rate mode is more efficient than our previous pulsed VMAT delivery.
引用
收藏
页数:12
相关论文
共 40 条
[1]   REIRRADIATION OF LARGE-VOLUME RECURRENT GLIOMA WITH PULSED REDUCED-DOSE-RATE RADIOTHERAPY [J].
Adkison, Jarrod B. ;
Tome, Wolfgang ;
Seo, Songwon ;
Richards, Gregory M. ;
Robins, H. Ian ;
Rassmussen, Karl ;
Welsh, James S. ;
Mahler, Peter A. ;
Howard, Steven P. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 79 (03) :835-841
[2]   THE TOLERANCE OF PRIMATE SPINAL-CORD TO REIRRADIATION [J].
ANG, KK ;
PRICE, RE ;
STEPHENS, LC ;
JIANG, GL ;
FENG, Y ;
SCHULTHEISS, TE ;
PETERS, LJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (03) :459-464
[3]   Pulsed Reduced Dose Rate Radiotherapy in Conjunction With Bevacizumab or Bevacizumab Alone in Recurrent High-grade Glioma: Survival Outcomes [J].
Bovi, Joseph A. ;
Prah, Melissa A. ;
Retzlaff, Amber A. ;
Schmainda, Kathleen M. ;
Connelly, Jennifer M. ;
Rand, Scott D. ;
Marszalkowski, Cathy S. ;
Mueller, Wade M. ;
Siker, Malika L. ;
Schultz, Christopher J. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (04) :979-986
[4]   Pulsed reduced dose-rate radiotherapy:: case report -: A novel re-treatment strategy in the management of recurrent glioblastoma multiforme [J].
Cannon, George M. ;
Tome, Wolfgang A. ;
Robins, H. Ian ;
Howard, Steven P. .
JOURNAL OF NEURO-ONCOLOGY, 2007, 83 (03) :307-311
[5]  
Chen LL, 2021, Mathews Journal of Cancer Science, V6, DOI [10.30654/mjcs.10027, 10.30654/MJCS.10027, DOI 10.30654/MJCS.10027]
[6]   Gamma Index Analysis as a Patient-Specific Quality Assurance Tool for High-Precision Radiotherapy: A Clinical Perspective of Single Institute Experience [J].
Das, Saikat ;
Kharade, Vipin ;
Pandey, V. P. ;
Anju, K., V ;
Pasricha, Rajesh K. ;
Gupta, Manish .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (10)
[7]   THE DOSE-RATE EFFECT REVISITED - RADIOBIOLOGICAL CONSIDERATIONS OF IMPORTANCE IN RADIOTHERAPY [J].
HALL, EJ ;
BRENNER, DJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (06) :1403-1414
[8]   Re-Irradiation of Recurrent Non-Small Cell Lung Cancer [J].
Hunter, Benjamin ;
Crockett, Cathryn ;
Faivre-Finn, Corrinne ;
Hiley, Crispin ;
Salem, Ahmed .
SEMINARS IN RADIATION ONCOLOGY, 2021, 31 (02) :124-132
[9]   Low-dose hypersensitivity: Current status and possible mechanisms [J].
Joiner, MC ;
Marples, B ;
Lambin, P ;
Short, SC ;
Turesson, I .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (02) :379-389
[10]   Optimization strategies for pulsed low-dose-rate IMRT of recurrent lung and head and neck cancers [J].
Kang, Shengwei ;
Lang, Jinyi ;
Wang, Pei ;
Li, Jie ;
Lin, Muhan ;
Chen, Xiaoming ;
Guo, Ming ;
Chen, Fu ;
Chen, Lili ;
Ma, Chang Ming .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (03) :102-113