Enhancing Ki-67 Prediction in Breast Cancer: Integrating Intratumoral and Peritumoral Radiomics From Automated Breast Ultrasound via Machine Learning

被引:6
作者
Li, Fang [1 ]
Zhu, Tong-wei [2 ]
Lin, Miao [3 ]
Zhang, Xiao-ting [1 ]
Zhang, Ya-li [1 ]
Zhou, Ai-li [1 ]
Huang, De-yi [1 ]
机构
[1] Peoples Hosp Yuhuan, Dept Ultrasound, 18 Changle Rd, Yuhuan City 317600, Zhejiang, Peoples R China
[2] Taizhou Hosp Zhejiang Prov, Dept Ultrasound, Taizhou, Zhejiang, Peoples R China
[3] Peoples Hosp Yuhuan, Dept Gen Surg 2, Yuhuan, Zhejiang, Peoples R China
关键词
Breast cancer; Ki-67; expression; Automated breast ultrasound system; Radiomics; Machine learning; PREOPERATIVE PREDICTION; CLASSIFICATION; BIOPSY; SIZE;
D O I
10.1016/j.acra.2023.12.036
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: Traditional Ki-67 evaluation in breast cancer (BC) via core needle biopsy is limited by repeatability and heterogeneity. The automated breast ultrasound system (ABUS) offers reproducibility but is constrained to morphological and echoic assessments. Radiomics and machine learning (ML) offer solutions, but their integration for improving Ki-67 predictive accuracy in BC remains unexplored. This study aims to enhance ABUS by integrating ML-assisted radiomics for Ki-67 prediction in BC, with a focus on both intratumoral and peritumoral regions. Materials and Methods: A retrospective analysis was conducted on 936 BC patients, split into training ( n = 655) and testing ( n = 281) cohorts. Radiomics features were extracted from intra- and peritumoral regions via ABUS. Feature selection involved Z-score normalization, intraclass correlation, Wilcoxon rank sum tests, minimum redundancy maximum relevance, and least absolute shrinkage and selection operator logistic regression. ML classifiers were trained and optimized for enhanced predictive accuracy. The interpretability of the optimized model was further augmented by employing Shapley additive explanations (SHAP). Results: Of the 2632 radiomics features in each patient, 15 were significantly associated with Ki-67 levels. The support vector machine (SVM) was identified as the optimal classifier, with area under the receiver operating characteristic curve values of 0.868 (training) and 0.822 (testing). SHAP analysis indicated that five peritumoral and two intratumoral features, along with age and lymph node status, were key determinants in the predictive model. Conclusion: Integrating ML with ABUS-based radiomics effectively enhances Ki-67 prediction in BC, demonstrating the SVM model's strong performance with both radiomics and clinical factors. (c) 2024 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:2663 / 2673
页数:11
相关论文
共 43 条
[1]   Peeking Inside the Black-Box: A Survey on Explainable Artificial Intelligence (XAI) [J].
Adadi, Amina ;
Berrada, Mohammed .
IEEE ACCESS, 2018, 6 :52138-52160
[2]  
Administration USFaD, 2012, Medical devices: somo-v Automated Breast Ultrasound System (ABUS): P110006
[3]   Correlation of three-dimensional magnetic resonance imaging with precise histopathological map concerning carcinoma extension in the breast [J].
Amano, G ;
Ohuchi, N ;
Ishibashi, T ;
Ishida, T ;
Amari, M ;
Satomi, S .
BREAST CANCER RESEARCH AND TREATMENT, 2000, 60 (01) :43-55
[4]   Reasons Women at Elevated Risk of Breast Cancer Refuse Breast MR Imaging Screening: ACRIN 6666 [J].
Berg, Wendie A. ;
Blume, Jeffrey D. ;
Adams, Amanda M. ;
Jong, Roberta A. ;
Barr, Richard G. ;
Lehrer, Daniel E. ;
Pisano, Etta D. ;
Evans, W. Phil, III ;
Mahoney, Mary C. ;
Larsen, Linda Hovanessian ;
Gabrielli, Glenna J. ;
Mendelson, Ellen B. .
RADIOLOGY, 2010, 254 (01) :79-87
[5]   Pros and Cons for Automated Breast Ultrasound (ABUS): A Narrative Review [J].
Boca , Ioana ;
Ciurea, Anca Ileana ;
Ciortea, Cristiana Augusta ;
Dudea, Sorin Marian .
JOURNAL OF PERSONALIZED MEDICINE, 2021, 11 (08)
[6]   Automated Breast Ultrasound (ABUS)-based radiomics nomogram: an individualized tool for predicting axillary lymph node tumor burden in patients with early breast cancer [J].
Chen, Yu ;
Xie, Yongwei ;
Li, Bo ;
Shao, Hua ;
Na, Ziyue ;
Wang, Qiucheng ;
Jing, Hui .
BMC CANCER, 2023, 23 (01)
[7]   Distribution pattern of the Ki67 labelling index in breast cancer and its implications for choosing cut-off values [J].
Cserni, Gabor ;
Voeroes, Andras ;
Liepniece-Karele, Inta ;
Bianchi, Simonetta ;
Vezzosi, Vania ;
Grabau, Dorthe ;
Sapino, Anna ;
Castellano, Isabella ;
Regitnig, Peter ;
Foschini, Maria Pia ;
Zolota, Vassiliki ;
Varga, Zsuzsanna ;
Figueiredo, Paulo ;
Decker, Thomas ;
Focke, Cornelia ;
Kulka, Janina ;
Kaya, Handan ;
Reiner-Concin, Angelika ;
Amendoeira, Isabel ;
Callagy, Grace ;
Caffrey, Emer ;
Wesseling, Jelle ;
Wells, Clive .
BREAST, 2014, 23 (03) :259-263
[8]   Automated breast volume scanner (ABVS) compared to handheld ultrasound (HHUS) and contrast-enhanced magnetic resonance imaging (CE-MRI) in the early assessment of breast cancer during neoadjuvant chemotherapy: an emerging role to monitoring tumor response? [J].
D'Angelo, Anna ;
Orlandi, Armando ;
Bufi, Enida ;
Mercogliano, Sara ;
Belli, Paolo ;
Manfredi, Riccardo .
RADIOLOGIA MEDICA, 2021, 126 (04) :517-526
[9]   Ki-67 as a Prognostic Biomarker in Invasive Breast Cancer [J].
Davey, Matthew G. ;
Hynes, Sean O. ;
Kerin, Michael J. ;
Miller, Nicola ;
Lowery, Aoife J. .
CANCERS, 2021, 13 (17)
[10]   Optimizing the Peritumoral Region Size in Radiomics Analysis for Sentinel Lymph Node Status Prediction in Breast Cancer [J].
Ding, Jie ;
Chen, Shenglan ;
Sosa, Mario Serrano ;
Cattell, Renee ;
Lei, Lan ;
Sun, Junqi ;
Prasanna, Prateek ;
Liu, Chunling ;
Huang, Chuan .
ACADEMIC RADIOLOGY, 2022, 29 :S223-S228