Comparison between Conventional and Digital Workflow in Implant Prosthetic Rehabilitation: A Randomized Controlled Trial

被引:0
|
作者
Corsalini, Massimo [1 ]
Barile, Giuseppe [1 ]
Ranieri, Francesco [2 ]
Morea, Edvige [3 ]
Corsalini, Tommaso [1 ]
Capodiferro, Saverio [1 ]
Palumbo, Rosario Roberto [2 ]
机构
[1] Aldo Moro Univ Bari, Dept Interdisciplinary Med, I-70100 Bari, Italy
[2] Magna Graecia Inst, Dept Prosthodont, I-74121 Taranto, Italy
[3] Univ G Dannunzio, Dept Med & Aging Sci, I-66100 Chieti, Italy
关键词
implant prosthesis; digital dentistry; digital workflow; IMPRESSIONS; ACCURACY;
D O I
10.3390/jfb15060149
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The progress of digital technologies in dental prosthodontics is fast and increasingly accurate, allowing practitioners to simplify their daily work. These technologies aim to substitute conventional techniques progressively, but their real efficiency and predictability are still under debate. Many systematic reviews emphasize the lack of clinical RCTs that compare digital and traditional workflow. To address this evidence, we conducted a three-arm designed clinical RCT, which compares fully digital, combined digital, and analogic and fully analog workflows. We aimed to compare the clinical properties of each workflow regarding interproximal (IC) and occlusal contact (OC), marginal fit, impression time (IT), and patient satisfaction through a VAS scale. In total, 72 patients were included in the study. The IC and OC of the digital workflow were better than the others (p < 0.001), which obtained similar results. No difference between implant-abutment fit was observed (p = 0.5966). The IT was shorter in the digital workflow than the others (p < 0.001), which were similar. Patient satisfaction was higher in the digital workflow than in the conventional one. Despite the limitations, this study's results support better accuracy and patient tolerance of digital workflow than of conventional techniques, suggesting it as a viable alternative to the latter when performed by clinicians experienced in digital dentistry.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Comparison of accuracy between digital and conventional implant impressions: two and three dimensional evaluations
    Bi, Chuang
    Wang, Xingyu
    Tian, Fangfang
    Qu, Zhe
    Zhao, Jiaming
    JOURNAL OF ADVANCED PROSTHODONTICS, 2022, 14 (04) : 236 - 249
  • [22] A Randomized Controlled Clinical Trial on Lithium Disilicate Veneers Manufactured by the CAD-CAM Method: Digital Versus Hybrid Workflow
    Verniani, Giulia
    Ferrari, Marco
    Manfredini, Daniele
    Cagidiaco, Edoardo Ferrari
    PROSTHESIS, 2024, 6 (02): : 329 - 340
  • [23] Patient-centered outcomes comparing digital and conventional implant impression procedures: a randomized crossover trial
    Joda, Tim
    Bragger, Urs
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (12) : E185 - E189
  • [24] Intrasubject comparison of digital vs. conventional workflow for screw-retained single-implant crowns: Prosthodontic and patient-centered outcomes
    Delize, Vincent
    Bouhy, Alice
    Lambert, France
    Lamy, Marc
    CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (09) : 892 - 902
  • [25] Digital Workflow for Fixed Implant Rehabilitation of an Extremely Atrophic Edentulous Mandible in Three Appointments
    Papaspyridakos, Panos
    Rajput, Neha
    Kudara, Yukio
    Weber, Hans-Peter
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2017, 29 (03) : 178 - 188
  • [26] Precision of digital implant models compared to conventional implant models for posterior single implant crowns: A within-subject comparison
    Muhlemann, Sven
    Greter, Elena A.
    Park, Ji-Man
    Hammerle, Christoph H. F.
    Thoma, Daniel S.
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (09) : 931 - 936
  • [27] Evaluation of the accuracy of conventional and digital implant impression techniques in bilateral distal extension cases: a randomized clinical trial
    Elashry, Wafaa Youssef
    Elsheikh, Mohamed Maamoun
    Elsheikh, Ali Mohamed
    BMC ORAL HEALTH, 2024, 24 (01):
  • [28] Clinical and laboratory passive fit assessment of implant-supported zirconia restorations fabricated using conventional and digital workflow
    Rutkunas, Vygandas
    Larsson, Christel
    von Steyern, Per Vult
    Mangano, Francesco
    Gedrimiene, Agne
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (02) : 237 - 245
  • [29] A comparison of conventional vs automated digital Peer Assessment Rating scoring using the Carestream 3600 scanner and CS Model plus software system: A randomized controlled trial
    Luqmani, Sana
    Jones, Allan
    Andiappan, Manoharan
    Cobourne, Martyn T.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2020, 157 (02) : 148 - +
  • [30] Comparison between patient-specific instruments and conventional instruments and computer navigation in total knee arthroplasty: a randomized controlled trial
    Yan, Chun Hoi
    Chiu, Kwong Yuen
    Ng, Fu Yuen
    Chan, Ping Keung
    Fang, Christian Xinshuo
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (12) : 3637 - 3645