Comparison of the Surgical Outcome between the Multiple Screw Fixation and Fixed Angle Devices for the Basicervical Femoral Neck Fractures

被引:0
|
作者
Kim, Jin-Woo [1 ]
Park, Jung-Wee [2 ]
Kim, Hyo-Jung [1 ]
Kim, Tae-Young [3 ]
Yoo, Jun-Il [4 ]
Lee, Young-Kyun [2 ]
Jang, Byung-Woong [5 ]
机构
[1] Nowon Eulji Med Ctr, Dept Orthopaed Surg, Seoul 01830, South Korea
[2] Seoul Natl Bundang Hosp, Dept Orthopaed Surg, Seongnam Si 13620, South Korea
[3] Konkuk Univ Hosp, Dept Orthopaed Surg, Seoul 05030, South Korea
[4] Inha Univ Hosp, Inha Univ, Coll Med, Dept Orthoped Surg, Incheon 22332, South Korea
[5] Soonchunhyang Univ, Seoul Hosp, Dept Orthopaed Surg, Seoul 04401, South Korea
来源
MEDICINA-LITHUANIA | 2024年 / 60卷 / 05期
基金
新加坡国家研究基金会;
关键词
femoral neck fracture; multiple screw fixation; fixed angle device; surgical outcome; HIP FRACTURE; OPERATIVE MANAGEMENT; INTERNAL-FIXATION; CANNULATED SCREW; ELDERLY-PATIENTS; FEMUR; NAIL;
D O I
10.3390/medicina60050680
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Basicervical femoral neck fracture (FNF) is an uncommon type of femoral neck fracture and is associated with an increased risk of fixation failure due to its inherent instability. The purpose of this study was to compare the surgical parameters and reoperation rate between the use of a multiple cannulated screw (MCS) and fixed angle device (FAD) in treating basicervical FNFs. Methods: We retrospectively reviewed the records of 885 patients who underwent internal fixation between May 2004 and August 2019 to determine basicervical FNF with at least 12 months of follow-up. Among the identified 77 patients with basicervical FNF, 17 patients who underwent multiple cannulated screw (MCS) fixation and 36 patients who underwent fixed angle device (FAD) fixation were included. We compared the rates of fracture-site collapse and reoperations according to the fixation device. Results: Among the 53 patients with basicervical FNF, 13 patients (24.5%) sustained surgical complications (8 collapses of fracture site and 5 reoperations). The reoperation rate in the MCS group was significantly higher than that in the FAD group (23.5% vs. 2.8%, p = 0.016), without any significant difference in the collapse of the fracture site (11.8% vs. 16.7%, p = 0.642). Conclusions: Although basicervical FNF was rare among hip fractures, fracture site collapse was prevalent and prone to fixation failure. Surgeons should keep this in mind, and consider FAD for basicervical FNF.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Biomechanical evaluation of the expansive cannulated screw for fixation of femoral neck fractures
    Zhang, Yang
    Tian, Li
    Yan, Yabo
    Sang, Hongxun
    Ma, Zhensheng
    Jie, Qiang
    Lei, Wei
    Wu, Zixiang
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 (11): : 1372 - 1376
  • [42] Screw Fixation Versus Hemiarthroplasty for Nondisplaced Femoral Neck Fractures in the Elderly: A Cost-Effectiveness Analysis
    Yong, Taylor M.
    Austin, Daniel C.
    Molloy, Ilda B.
    Kunkel, Samuel T.
    Jevsevar, David S.
    Gitajn, Ida L.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2020, 34 (07) : 348 - 355
  • [43] Does the angle between dynamic hip screw and anti-rotation screw affect the outcome of vertically oriented femoral neck fractures? A biomechanical analysis and clinical results
    Xian, Hang
    Cheng, Weike
    Xie, Wei
    Wang, Lei
    Luo, Deqing
    Liu, Hui
    Lian, Kejian
    Lin, Dasheng
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2024, 55 (03):
  • [44] Biplane double-supported screw fixation (F-technique): a method of screw fixation at osteoporotic fractures of the femoral neck
    Filipov, Orlin
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2011, 21 (07) : 539 - 543
  • [45] Low avascular necrosis rates in femoral neck fractures: efficacy of cannulated screw fixation
    Scattergood, S. D.
    Berry, A. L.
    Flannery, O.
    Burdon, A.
    Mitchell, S. R.
    Fletcher, J. W. A.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2024, 34 (05) : 2565 - 2571
  • [46] Factors that influence the complications and outcomes of femoral neck fractures treated by cannulated screw fixation
    Ramadanov, Nikolai
    Toma, Ionel
    Herkner, Harald
    Klein, Roman
    Behringer, Wilhelm
    Matthes, Gerrit
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [47] Comparison of femoral neck system to multiple cancellous screws and dynamic hip screws in the treatment of femoral neck fractures
    Xu, Xiangyu
    Fan, Jixing
    Zhou, Fang
    Lv, Yang
    Tian, Yun
    Ji, Hongquan
    Zhang, Zhishan
    Guo, Yan
    Yang, Zhongwei
    Hou, Guojin
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54 : S28 - S35
  • [48] Internal fixation of undisplaced femoral neck fractures in the elderly: A retrospective comparison of fixation methods
    Lee, Yih-Shiunn
    Chen, Shih-Hao
    Tsuang, Yang-Hwei
    Huang, Hui-Ling
    Lo, Ting-Ying
    Huang, Chien-Rae
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2008, 64 (01): : 155 - 162
  • [49] Treatment of Femoral Neck Fractures in Adults With Improved Biplane Double-Supported Screw Fixation and Femoral Neck System: Complications and Surgical Techniques
    Zhang, Xiaolong
    Feng, Xiwen
    Ouyang, Lingfei
    Shu, Shan
    Zhuang, Lebin
    Gui, Weichao
    Zhang, Sheng
    Yao, Zilong
    Wang, Gang
    Liao, Hua
    Hu, Jijie
    ORTHOPAEDIC SURGERY, 2025, : 1057 - 1066
  • [50] Comparison of morphological features in the femur between femoral neck fractures and femoral intertrochanteric fractures
    Yamauchi, Koun
    Naofumi, Mitsuishi
    Sumida, Hisashi
    Fukuta, Shoji
    Hori, Hirohiko
    SURGICAL AND RADIOLOGIC ANATOMY, 2016, 38 (07) : 775 - 780