Comparison of the Surgical Outcome between the Multiple Screw Fixation and Fixed Angle Devices for the Basicervical Femoral Neck Fractures

被引:0
|
作者
Kim, Jin-Woo [1 ]
Park, Jung-Wee [2 ]
Kim, Hyo-Jung [1 ]
Kim, Tae-Young [3 ]
Yoo, Jun-Il [4 ]
Lee, Young-Kyun [2 ]
Jang, Byung-Woong [5 ]
机构
[1] Nowon Eulji Med Ctr, Dept Orthopaed Surg, Seoul 01830, South Korea
[2] Seoul Natl Bundang Hosp, Dept Orthopaed Surg, Seongnam Si 13620, South Korea
[3] Konkuk Univ Hosp, Dept Orthopaed Surg, Seoul 05030, South Korea
[4] Inha Univ Hosp, Inha Univ, Coll Med, Dept Orthoped Surg, Incheon 22332, South Korea
[5] Soonchunhyang Univ, Seoul Hosp, Dept Orthopaed Surg, Seoul 04401, South Korea
来源
MEDICINA-LITHUANIA | 2024年 / 60卷 / 05期
基金
新加坡国家研究基金会;
关键词
femoral neck fracture; multiple screw fixation; fixed angle device; surgical outcome; HIP FRACTURE; OPERATIVE MANAGEMENT; INTERNAL-FIXATION; CANNULATED SCREW; ELDERLY-PATIENTS; FEMUR; NAIL;
D O I
10.3390/medicina60050680
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Basicervical femoral neck fracture (FNF) is an uncommon type of femoral neck fracture and is associated with an increased risk of fixation failure due to its inherent instability. The purpose of this study was to compare the surgical parameters and reoperation rate between the use of a multiple cannulated screw (MCS) and fixed angle device (FAD) in treating basicervical FNFs. Methods: We retrospectively reviewed the records of 885 patients who underwent internal fixation between May 2004 and August 2019 to determine basicervical FNF with at least 12 months of follow-up. Among the identified 77 patients with basicervical FNF, 17 patients who underwent multiple cannulated screw (MCS) fixation and 36 patients who underwent fixed angle device (FAD) fixation were included. We compared the rates of fracture-site collapse and reoperations according to the fixation device. Results: Among the 53 patients with basicervical FNF, 13 patients (24.5%) sustained surgical complications (8 collapses of fracture site and 5 reoperations). The reoperation rate in the MCS group was significantly higher than that in the FAD group (23.5% vs. 2.8%, p = 0.016), without any significant difference in the collapse of the fracture site (11.8% vs. 16.7%, p = 0.642). Conclusions: Although basicervical FNF was rare among hip fractures, fracture site collapse was prevalent and prone to fixation failure. Surgeons should keep this in mind, and consider FAD for basicervical FNF.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Intramedullary nails with cannulated screw fixation for the treatment of unstable femoral neck fractures
    Guo, Jialiang
    Dong, Weichong
    Yin, Bing
    Jin, Lin
    Lin, Zhe
    Hou, Zhiyong
    Zhang, Yingze
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2019, 47 (02) : 557 - 568
  • [32] Comparison of femoral neck shortening and outcomes between in situ fixation and fixation after reduction for severe valgus-impacted femoral neck fractures
    Park, Young-Chang
    Um, Kyu-Sub
    Kim, Dong-Jin
    Byun, Junwoo
    Yang, Kyu-Hyun
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2021, 52 (03): : 569 - 574
  • [33] Comparison of Ordinary Cannulated Compression Screw and Double-Head Cannulated Compression Screw Fixation in Vertical Femoral Neck Fractures
    Zhang, Yuelei
    Yan, Chao
    Zhang, Lecheng
    Zhang, Wei
    Wang, Gang
    BIOMED RESEARCH INTERNATIONAL, 2020, 2020
  • [34] Comparison Between Femoral Neck Systems and Cannulated Cancellous Screws in Treating Femoral Neck Fractures: A Meta-Analysis
    Tian, Peng
    Kuang, Lan
    Li, Zhi-jun
    Xu, Gui-jun
    Fu, Xin
    GERIATRIC ORTHOPAEDIC SURGERY & REHABILITATION, 2022, 13
  • [35] Valgus osteotomy in delayed presentation of femoral neck fractures using fixed angle simple dynamic hip screw and plate
    Nayak, Chandrakant
    Acharyya, Biplab
    Jain, Mantu
    Kamboj, Kulbhushan
    CHINESE JOURNAL OF TRAUMATOLOGY, 2019, 22 (01) : 29 - 33
  • [36] Biomechanical comparison of five cannulated screw fixation strategies for young vertical femoral neck fractures
    Jiang, Dajun
    Zhan, Shi
    Wang, Lei
    Shi, Lewis L.
    Ling, Ming
    Hu, Hai
    Jia, Weitao
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2021, 39 (08) : 1669 - 1680
  • [37] Comparative Short-Term Outcomes of Femoral Neck System (FNS) and Cannulated Screw Fixation in Patients with Femoral Neck Fractures: A Multicenter Study
    Chung, HoeJeong
    Kim, Youngwoo
    Kook, Incheol
    Kwak, Ji Woong
    Hwang, Kyu Tae
    CLINICS IN ORTHOPEDIC SURGERY, 2024, 16 (02) : 184 - 193
  • [38] Results of fixed-angle device fixation (dynamic hip screw) in femoral neck fractures in young adults: a prospective study of 20 cases
    Beder, Fady Kamal
    El-Hamalawy, Ahmed Goda
    Abdel-Kader, Khaled F. M.
    Abdelmoneim, Mohamed A.
    CURRENT ORTHOPAEDIC PRACTICE, 2021, 32 (04): : 333 - 338
  • [39] Provisional fixation of unstable femoral neck basicervical fractures: A web-based survey and biomechanical assessment using a sliding hip screw construct
    Alzahrani, Mohammad M.
    Culliton, Kathryn N.
    Wilkin, Geoffrey P.
    Papp, Steven R.
    Liew, Allan S.
    JOURNAL OF MUSCULOSKELETAL SURGERY AND RESEARCH, 2022, 6 (01) : 70 - 76
  • [40] Correlation Between Residual Displacement and Osteonecrosis of the Femoral Head Following Cannulated Screw Fixation of Femoral Neck Fractures
    Wang, Chen
    Xu, Gui-Jun
    Han, Zhe
    Jiang, Xuan
    Zhang, Cheng-Bao
    Dong, Qiang
    Ma, Jian-Xiong
    Ma, Xin-Long
    MEDICINE, 2015, 94 (47) : e2139