Comparison of the Surgical Outcome between the Multiple Screw Fixation and Fixed Angle Devices for the Basicervical Femoral Neck Fractures

被引:0
|
作者
Kim, Jin-Woo [1 ]
Park, Jung-Wee [2 ]
Kim, Hyo-Jung [1 ]
Kim, Tae-Young [3 ]
Yoo, Jun-Il [4 ]
Lee, Young-Kyun [2 ]
Jang, Byung-Woong [5 ]
机构
[1] Nowon Eulji Med Ctr, Dept Orthopaed Surg, Seoul 01830, South Korea
[2] Seoul Natl Bundang Hosp, Dept Orthopaed Surg, Seongnam Si 13620, South Korea
[3] Konkuk Univ Hosp, Dept Orthopaed Surg, Seoul 05030, South Korea
[4] Inha Univ Hosp, Inha Univ, Coll Med, Dept Orthoped Surg, Incheon 22332, South Korea
[5] Soonchunhyang Univ, Seoul Hosp, Dept Orthopaed Surg, Seoul 04401, South Korea
来源
MEDICINA-LITHUANIA | 2024年 / 60卷 / 05期
基金
新加坡国家研究基金会;
关键词
femoral neck fracture; multiple screw fixation; fixed angle device; surgical outcome; HIP FRACTURE; OPERATIVE MANAGEMENT; INTERNAL-FIXATION; CANNULATED SCREW; ELDERLY-PATIENTS; FEMUR; NAIL;
D O I
10.3390/medicina60050680
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Basicervical femoral neck fracture (FNF) is an uncommon type of femoral neck fracture and is associated with an increased risk of fixation failure due to its inherent instability. The purpose of this study was to compare the surgical parameters and reoperation rate between the use of a multiple cannulated screw (MCS) and fixed angle device (FAD) in treating basicervical FNFs. Methods: We retrospectively reviewed the records of 885 patients who underwent internal fixation between May 2004 and August 2019 to determine basicervical FNF with at least 12 months of follow-up. Among the identified 77 patients with basicervical FNF, 17 patients who underwent multiple cannulated screw (MCS) fixation and 36 patients who underwent fixed angle device (FAD) fixation were included. We compared the rates of fracture-site collapse and reoperations according to the fixation device. Results: Among the 53 patients with basicervical FNF, 13 patients (24.5%) sustained surgical complications (8 collapses of fracture site and 5 reoperations). The reoperation rate in the MCS group was significantly higher than that in the FAD group (23.5% vs. 2.8%, p = 0.016), without any significant difference in the collapse of the fracture site (11.8% vs. 16.7%, p = 0.642). Conclusions: Although basicervical FNF was rare among hip fractures, fracture site collapse was prevalent and prone to fixation failure. Surgeons should keep this in mind, and consider FAD for basicervical FNF.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Performing Screw Fixation for Femoral Neck Fractures under Local Anaesthesia
    Chor-Yat, Chung
    Wong Sze-Hung
    JOURNAL OF ORTHOPAEDICS TRAUMA AND REHABILITATION, 2012, 16 (02) : 55 - 58
  • [22] A comparison of hemiarthroplasty versus dynamic hip screw fixation for intertrochanteric femoral fractures: a systematic review
    Chowdhury, Alex K.
    Townsend, Oliver
    Edwards, Max R.
    HIP INTERNATIONAL, 2023, 33 (04) : 752 - 761
  • [23] Biplane Double-supported Screw Fixation of Femoral Neck Fractures: Surgical Technique and Surgical Notes
    Filipov, Orlin B.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2019, 27 (11) : E507 - E515
  • [24] Effect of integrity of the posterior cortex in displaced femoral neck fractures on outcome after surgical fixation in young adults
    Huang, Tsan-Wen
    Hsu, Wei-Hsiu
    Peng, Kuo-Ti
    Lee, Ching-Yu
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 (02): : 217 - 222
  • [25] Biomechanical comparison of antirotator compression hip screw and cannulated screw fixations in the femoral neck fractures
    Saglam, Necdet
    Kucukdurmaz, Fatih
    Kivilcim, Hakan
    Kurtulmus, Tuhan
    Sen, Cengiz
    Akpinar, Fuat
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2014, 48 (02) : 196 - 201
  • [26] Cancellous screw fixation for undisplaced femoral neck fractures in the elderly
    Manohara, Ruben
    Liang, Shen
    Huang, Deborah
    Krishna, Lingaraj
    JOURNAL OF ORTHOPAEDIC SURGERY, 2014, 22 (03) : 282 - 286
  • [27] Comparison of femoral neck shortening after femoral neck system and cannulated cancellous screw fixation for displaced femoral neck fractures in young adults
    Zheng, Shunze
    Lin, Dongze
    Chen, Peisheng
    Lin, Chaohui
    Chen, Bin
    Zheng, Ke
    Lin, Fengfei
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2024, 55 (06):
  • [28] Four quadrant parallel peripheral screw fixation for displaced femoral neck fractures in elderly patients
    Satish, Bhava R. J.
    Ranganadham, Atmakuri V.
    Ramalingam, Karruppasamy
    Tripathy, Sujit Kumar
    INDIAN JOURNAL OF ORTHOPAEDICS, 2013, 47 (02) : 174 - 181
  • [29] Subtrochanteric fracture : A rare but severe complication after screw fixation of femoral neck fractures in the elderly
    Jansen, Hendrik
    Frey, Soenke P.
    Meffert, Rainer H.
    ACTA ORTHOPAEDICA BELGICA, 2010, 76 (06): : 778 - 784
  • [30] A new configuration of cannulated screw fixation in the treatment of vertical femoral neck fractures
    Zhang, Baokun
    Liu, Jingwen
    Zhu, Yi
    Zhang, Wei
    INTERNATIONAL ORTHOPAEDICS, 2018, 42 (08) : 1949 - 1955