Performance study on modularized ultra-low-grade-heat-driven desiccant-coated oblique tube banks in tropics

被引:0
作者
Shang, Runxin [1 ]
Jagirdar, Mrinal [2 ]
Lee, Poh Seng [1 ]
机构
[1] Natl Univ Singapore, Coll Design & Engn, Dept Mech Engn, Cooling Energy Sci Technol Lab, Singapore City 117576, Singapore
[2] Birla Inst Technol & Sci Pilani, Dept Mech Engn, Hyderabad Campus, Pilani 500078, India
关键词
Solid desiccant; Dehumidification; Low-grade heat; HVAC; Heat exchanger; SYSTEM; PUMP; EXCHANGER;
D O I
10.1016/j.applthermaleng.2024.123094
中图分类号
O414.1 [热力学];
学科分类号
摘要
In hot and humid subtropical and tropical climates where the latent cooling load significantly impacts the fresh air and total cooling load, substantial energy can be consumed in the air dehumidification process. This study delves into solid desiccant-assisted dehumidification employing ultra-low-grade waste heat (as low as 38.1 degrees C), investigated through both experimental and numerical analyses of an internally cooled desiccant-coated oblique tube bank configuration. This novel heat exchanger design eliminates the thermal contact resistance in some tube-fin heat exchangers, enhancing the efficient utilization of waste condensation heat in air conditioning systems. Comparative analysis against a circular tube bank with identical tube surface area and tube pitches demonstrates a remarkable reduction of more than 90 % in air pressure drop, accompanied by a significant 73 % enhancement in flow uniformity in the main direction. The experimental results demonstrate an electrical coefficient of performance ranging from 30 to 108 for the proposed desiccant-coated heat exchanger, highlighting its potential for energy-efficient air dehumidification. Furthermore, the study examines the influence of key operational parameters on the capacity and performance of the proposed desiccant-coated heat exchanger in tropical climates, indicating that even with a minimum 7.9 degrees C temperature difference between warm water and cool water, the heat exchanger maintains a 3.0 g/kg dehumidification ratio. The effect of water flow rate, air flow rate, inlet air specific humidity, cool water temperature, warm water temperature, and desiccant thickness on the performance of the proposed DCHX system are discussed in detail.
引用
收藏
页数:21
相关论文
共 31 条
[11]  
Incropera F.P., 2011, Fundamentals of Heat and Mass Transfer, DOI DOI 10.1109/TKDE.2004.30
[12]   Mathematical modeling and performance evaluation of a desiccant coated fin-tube heat exchanger [J].
Jagirdar, Mrinal ;
Lee, Poh Seng .
APPLIED ENERGY, 2018, 212 :401-415
[13]   A numerical and experimental investigation of heat transfer and fluid flow characteristics of an air-cooled oblique-finned heat sink [J].
Kanargi, Bugra ;
Lee, Poh Seng ;
Yap, Christopher .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 116 :393-416
[14]  
Khoo K.L., 2018, International Journal of Refrigeration
[15]  
Khoo KL, 2016, INTERSOC C THERMAL T, P625, DOI 10.1109/ITHERM.2016.7517606
[16]   Case study and theoretical analysis of a solar driven two-stage rotary desiccant cooling system assisted by vapor compression air-conditioning [J].
La, Dong ;
Dai, Yanjun ;
Li, Yong ;
Ge, Tianshu ;
Wang, Ruzhu .
SOLAR ENERGY, 2011, 85 (11) :2997-3009
[17]  
Law M., 2017, Numerical Study of Fluid Flow in Different Manifold Configurations for Vanadium Redox Flow Battery
[18]   Enhanced Thermal Transport in Microchannel Using Oblique Fins [J].
Lee, Y. J. ;
Lee, P. S. ;
Chou, S. K. .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2012, 134 (10)
[19]   Energy effectiveness analysis of desiccant coated heat exchanger based on numerical method [J].
Liu, M. Z. ;
Vivekh, P. ;
Chen, W. D. ;
Chua, K. J. .
APPLIED THERMAL ENGINEERING, 2023, 220
[20]   PERFORMANCE OF AN OPEN-CYCLE DESICCANT COOLING SYSTEM USING ADVANCED DESICCANT MATRICES [J].
MAJUMDAR, P ;
WOREK, WM .
HEAT RECOVERY SYSTEMS & CHP, 1989, 9 (04) :299-311