DYNAMIC MODEL OF MULTISTAGE CENTRIFUGAL COMPRESSOR WITH A STAGE-BY-STAGE ANTI-SURGE RECIRCULATING SYSTEM

被引:0
作者
Casari, Nicola [1 ]
Pinelli, Michele [1 ]
Suman, Alessio [1 ]
Manganelli, Matteo [2 ]
Morini, Mirko [2 ]
Brun, Klaus [3 ]
Larosiliere, Louis [3 ]
Jariwala, Vishal [3 ]
机构
[1] Univ Ferrara, Via Saragat 1, I-44122 Ferrara, IT, Italy
[2] Univ Parma, Parco Area Sci 181-A, I-43124 Parma, IT, Italy
[3] Elliott Grp, Jeannette, PA USA
来源
PROCEEDINGS OF ASME TURBO EXPO 2021: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, VOL 8 | 2021年
关键词
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The operability region of a centrifugal compressor is bounded by the low-flow (or high-pressure ratio) limit, commonly referred to as surge. The exact location of the surge line on the map can vary depending on the operating condition and, as a result, a typical Surge Avoidance Line is established at 10% to 15% above the stated flow for the theoretical surge line. The current state of the art of centrifugal compressor surge control is to utilize a global recycle valve to return flow from the discharge side of a centrifugal compressor to the suction side to increase the flow through the compressor and, thus, avoid entering the surge region. This is conventionally handled by defining a compressor surge control line that conservatively assumes that all stages must be kept out of surge at all the time. In compressors with multiple stages, the amount of energy loss is disproportionally large since the energy that was added in each stage is lost during system level (or global) recycling. This work proposes an internal stage-wise recycling that provides a much more controlled flow recycling to affect only those stages that may be on the verge of surge. The amount of flow needed for such a scheme will be much smaller than highly conservative global recycling approach. Also, the flow does not leave the compressor casing and therefore does not cross the pressure boundary. Compared to global recycling this inherently has less loss depending upon application and specific of control design.
引用
收藏
页数:15
相关论文
共 13 条
  • [1] ASME, 1997, ASME PTC10: Performance test code on compressors and exhausters
  • [2] Supercritical fluid recycle for surge control of CO2 centrifugal compressors
    Budinis, Sara
    Thornhill, Nina F.
    [J]. COMPUTERS & CHEMICAL ENGINEERING, 2016, 91 : 329 - 342
  • [3] Cameron, 2018, Tech. rep
  • [4] Cengel Y.A., 2010, FLUID MECH-SOV RES
  • [5] Dixon S.L., 2013, FLUID MECH THERMODYN, V7th
  • [6] SURGE AND ROTATING STALL IN AXIAL-FLOW COMPRESSORS .1. THEORETICAL COMPRESSION SYSTEM MODEL
    GREITZER, EM
    [J]. JOURNAL OF ENGINEERING FOR POWER-TRANSACTIONS OF THE ASME, 1976, 98 (02): : 190 - 198
  • [7] Idelchik I. E., 1986, Handbook of Hydraulic Resistance
  • [8] Kurz R., 2004, ASME Turbo Expo 2004: Power for Land, Sea, and Air, P735
  • [9] Ludtke K.H., 2004, PROCESS CENTRIFUGAL
  • [10] Development of a one-dimensional modular dynamic model for the simulation of surge in compression systems
    Morini, M.
    Pinelli, M.
    Venturini, M.
    [J]. JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2007, 129 (03): : 437 - 447