Influence of Voxel Size on CBCT Images for Dental Implants Planning

被引:7
作者
Kehrwald, Ricardo [1 ]
de Castro, Hebert Sampaio [1 ]
Salmeron, Samira [1 ]
Matheus, Ricardo Alves [2 ]
Santaella, Gustavo Machado [3 ]
Queiroz, Polyane Mazucatto [4 ,5 ]
机构
[1] Inga Ctr Univ Maringa, Dept Dent, Area Implantol, Maringa, Parana, Brazil
[2] Univ Estadual Londrina, Dept Oral Med, Div Oral Radiol, Londrina, Parana, Brazil
[3] Univ Louisville, Dept Diag & Oral Hlth, Div Oral Radiol, Louisville, KY USA
[4] Inga Ctr Univ Maringa, Dept Dent, Div Oral Radiol, Area Oral Radiol, Maringa, Parana, Brazil
[5] Inga Univ Ctr, Dept Dent, Area Implantol, 6114 Rod PR 317, BR-87035510 Maringa, Parana, Brazil
关键词
cone beam computed tomography; dental implants; diagnosis; dimensional measurement accuracy; implant planning; jaw edentulous; mandible; BEAM COMPUTED-TOMOGRAPHY; LINEAR MEASUREMENTS; ROOT FRACTURES; ACCURACY; VIEW;
D O I
10.1055/s-0041-1736388
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective This study was developed to evaluate the influence of voxel size on bone measurements for implant planning. Materials and Methods The research was performed by using edentulous synthetic human mandibles with different levels of bone resorption. For each mandible, height and bone thickness were measured with a digital caliper. The PaX-i3d device was used to acquire the volumes of the five mandibles, with 50kVp, 4mA, and a voxel size of 0.08 mm. After the acquisition, the images were reconstructed in the software CS three-dimensional Imaging, with four different sizes of voxels: 0.1, 0.2, 0.3, and 0.4mm. All volumes were analyzed by a single evaluator who performed measurements to obtain bone height and thickness, using the reference points that were considered in obtaining the gold standard. The data were analyzed by ANOVA with a significance level of 5%. Results There was no significant difference in the measurements obtained with different voxel sizes, both for bone height measurements and bone thickness. There was no statistically significant difference in measurements in thickness in comparison to the gold standard. Conclusion When necessary, to measure height and bone thickness, it is possible to recommend voxel images of larger size (0.40 mm) without compromising the quality of the patient's clinical planning.
引用
收藏
页码:381 / 385
页数:5
相关论文
共 25 条
  • [1] Contrast-to-noise ratio difference in small field of view cone beam computed tomography machines
    Bechara, Boulos
    McMahan, Clyde A.
    Moore, William S.
    Noujeim, Marcel
    Geha, Hassem
    Teixeira, Fabricio B.
    [J]. JOURNAL OF ORAL SCIENCE, 2012, 54 (03) : 227 - 232
  • [2] Bragatto Fernanda Paula, 2016, J Conserv Dent, V19, P573
  • [3] Spatial resolution in CBCT machines for dental/maxillofacial applications-what do we know today?
    Bruellmann, D.
    Schulze, R. K. W.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2015, 44 (01)
  • [4] Carraro G., 2014, Journal of Oral Investigations, V3, P31, DOI [10.18256/2238-510x/j.oralinvestigations.v3n2p31-36, DOI 10.18256/2238-510X/J.ORALINVESTIGATIONS.V3N2P31-36]
  • [5] Costa AN, 2018, J BRAS PNEUMOL, V44, P424, DOI [10.1590/S1806-37562017000000209, 10.4317/jced.54500, 10.1590/s1806-37562017000000209]
  • [6] Accuracy of in vitro mandibular volumetric measurements from CBCT of different voxel sizes with different segmentation threshold settings
    Dong, Ting
    Xia, Lunguo
    Cai, Chenglin
    Yuan, Lingjun
    Ye, Niansong
    Fang, Bing
    [J]. BMC ORAL HEALTH, 2019, 19 (01)
  • [7] Detection of alveolar bone defects with three different voxel sizes of cone-beam computed tomography: an in vitro study
    Dong, Ting
    Yuan, Lingjun
    Liu, Lu
    Qian, Yifeng
    Xia, Lunguo
    Ye, Niansong
    Fang, Bing
    [J]. SCIENTIFIC REPORTS, 2019, 9 (1)
  • [8] Farman A.G., 2009, Semi-nars in Orthodontics, V15, P2, DOI [10.1053/j.sodo.2008.09.001, DOI 10.1053/J.SODO.2008.09.001]
  • [9] Accuracy of linear measurements on CBCT images related to presurgical implant treatment planning: A systematic review
    Fokas, George
    Vaughn, Vida M.
    Scarfe, William C.
    Bornstein, Michael M.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 : 393 - 415
  • [10] The accuracy of linear measurements of maxillary and mandibular edentulous sites in cone-beam computed tomography images with different fields of view and voxel sizes under simulated clinical conditions
    Ganguly, Rumpa
    Ramesh, Aruna
    Pagni, Sarah
    [J]. IMAGING SCIENCE IN DENTISTRY, 2016, 46 (02) : 93 - 101