The potential for cool roofs to improve the energy efficiency of single storey warehouse-type retail buildings in Australia: A simulation case study

被引:49
作者
Seifhashemi, M. [1 ,2 ]
Capra, B. R. [2 ]
Milller, W. [2 ]
Bell, J. [2 ]
机构
[1] Univ Salford, Sch Built Environm, Salford, Lancs, England
[2] Queensland Univ Technol, Sci & Engn Fac, Brisbane, Qld, Australia
关键词
Building simulation; Cool roof; Energy efficiency; CO2 emissions reduction; Retail building; COATINGS; COMFORT; SAVINGS; IMPACT;
D O I
10.1016/j.enbuild.2017.11.034
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Australia's commercial building stock exceeds 134 million m(2) of net lettable area, with retail buildings contributing 35% to this sector's energy use. The energy intensity of retail buildings in hotter climates is higher than the national average, as is the energy intensity of smaller buildings (under 1500 m(2)) that are not considered 'high-end' commercial properties. Little attention has been paid to improving the energy efficiency of these types of buildings through regulation (for new buildings) or through market mechanisms (for retrofitting). As many of these buildings are single storey 'warehouse' type buildings, their predominant heat load comes through the roof, and thus are well suited to benefit from cool roof technology. Despite this, there remains a deficiency in quantifying the benefit of such technology in the context of single-storey retail buildings in Australia. This paper reports on an experimentally validated numerical study aimed at addressing this deficiency. Results show that application of cool roof technology to a warehouse type building in a subtropical environment increases the energy efficiency by shifting space temperature towards the design set point (21-23 degrees C), and thus reducing cooling energy demand. This study also indicates an energy saving every month with the application of cool roof, with the largest saving in hotter months and no heating penalty in cooler months. Application of cool roof technology on warehouse style buildings across Australian buildings indicates energy savings can be achieved in all broad Australian climatic zones, with the greatest energy reduction associated with tropical, subtropical and desert environments. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:1393 / 1403
页数:11
相关论文
共 38 条
[1]   Monitoring the energy-use effects of cool roofs on California commercial buildings [J].
Akbari, H ;
Levinson, R ;
Rainer, L .
ENERGY AND BUILDINGS, 2005, 37 (10) :1007-1016
[2]   Calculating energy-saving potentials of heat-island reduction strategies [J].
Akbari, H ;
Konopacki, S .
ENERGY POLICY, 2005, 33 (06) :721-756
[3]   Cool surfaces and shade trees to reduce energy use and improve air quality in urban areas [J].
Akbari, H ;
Pomerantz, M ;
Taha, H .
SOLAR ENERGY, 2001, 70 (03) :295-310
[4]   Peak power and cooling energy savings of high-albedo roofs [J].
Akbari, H ;
Bretz, S ;
Kurn, DM ;
Hanford, J .
ENERGY AND BUILDINGS, 1997, 25 (02) :117-126
[5]   Global cooling updates: Reflective roofs and pavements [J].
Akbari, Hashem ;
Matthews, H. Damon .
ENERGY AND BUILDINGS, 2012, 55 :2-6
[6]   Evolution of Cool-Roof Standards in the US [J].
Akbari, Hashem ;
Levinson, Ronnen .
ADVANCES IN BUILDING ENERGY RESEARCH, 2008, 2 (01) :1-32
[7]   Global cooling: increasing world-wide urban albedos to offset CO2 [J].
Akbari, Hashem ;
Menon, Surabi ;
Rosenfeld, Arthur .
CLIMATIC CHANGE, 2009, 94 (3-4) :275-286
[8]  
AlAwadhi W., 2013, Scientific Research: Engineering, V5, P132
[9]   Courtyard Design Variants and Microclimate Performance [J].
Almhafdy, Abdulbasit ;
Ibrahim, Norhati ;
Ahmad, Sabarinah Sh ;
Yahya, Josmin .
AMER (ABRA MALAYSIA) INTERNATIONAL CONFERENCE ON QUALITY OF LIFE, AICQOL2013, 2013, 101 :170-180
[10]  
[Anonymous], 2016, NCC VOL 2 EN EFF PRO