Operation Scheduling of Distribution Network with Photovoltaic/Wind/Battery Multi-Microgrids and Reconfiguration considering Reliability and Self-Healing

被引:1
作者
Kalantari, Alireza [1 ]
Lesani, Hamid [1 ]
机构
[1] Univ Tehran, Coll Engn, Sch Elect & Comp Engn, Tehran, Iran
关键词
DISTRIBUTION-SYSTEMS; OPTIMIZATION; GENERATION; PLACEMENT; MODEL;
D O I
10.1155/2024/5724653
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this paper, a new simultaneous framework of distribution network operation is proposed based on the scheduling of photovoltaic/wind/battery multi-microgrids with network reconfiguration considering self-healing. The objective function is considered to minimize the energy losses, and multi-microgrids cost and improve the reliability indices including minimization of energy not-supplied (ENS) and minimizing system average interruption duration (SAIDI) and system average interruption frequency (SAIFI) indices. The optimization variables are defined as the situation of the distribution network switches to find the network's optimal configuration with the installation location and size of renewable resources and battery energy storage during 24 hours. An improved beluga whale optimization (IBWO) based on a nonlinearly diminishing inertia weight (NDIW) approach is used to find the optimal variable set of the problem. The recommended methodology is implemented on 33-bus and real 59-bus distribution networks. The results demonstrated that by obtaining an optimal state of the network switches in the event of a fault, as well as the optimal scheduling of the two microgrids, the energy losses have decreased and the reliability indices have improved. The outcomes of the proposed methodology based on the hybrid multi-microgrid allocation and network reconfiguration are stated that the losses, ENS, SAIDI, and SAIFI are reduced by 66.39%, 54.00%, 50.24%, and 33.61%, respectively, for 33-bus network and are declined by 65.29%, 57.44%, 48.63%, and 62.33%, respectively, for the real 59-bus Ahvaz network in comparison with the base network. The obtained results illustrated that in the condition of the network line outage, by simultaneously implementing the reconfiguration with the change of network switches and the optimal allocation and scheduling of HMGs in the network, self-healing is provided to prevent a significant weakening of the network performance so that the resilience is improved in addition to minimizing the energy losses and the cost of HMG energy injection compared to the base network. The findings revealed that the objectives including losses, ENS, SAIFI, and SAIDI are increased by 78.29%, 33.00%, 83.33%, and 35.11%, respectively, due to outage of line 22 of the 33-bus network and these objectives are increased by 52.32%, 10.30%, 32.29%, and 79.66%, respectively, due to outage of line 12 of the 59-bus network compared with not considering the line outage. Moreover, the superior capability of the recommended NDIW-based IBWO has been confirmed in comparison with the well-known particle swarm optimizer (PSO) and ant lion optimizer (ALO) in solving the problem to achieve better objective value.
引用
收藏
页数:31
相关论文
共 36 条
  • [21] Stochastic optimization-based economic design for a hybrid sustainable system of wind turbine, combined heat, and power generation, and electric and thermal storages considering uncertainty: A case study of Espoo, Finland
    Nowdeh, Saber Arabi
    Naderipour, Amirreza
    Davoudkhani, Iraj Faraji
    Guerrero, Josep M.
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2023, 183
  • [22] Reassessing Self-Healing in Metallized Film Capacitors: A Focus on Safety and Damage Analysis
    Pan, Lei
    Wang, Feipeng
    He, Yushuang
    Sun, Xinbo
    Du, Guoqiang
    Zhou, Quantong
    Zhang, Jie
    Zhang, Zhicheng
    Li, Jian
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2024, 31 (04) : 1666 - 1675
  • [23] A mixed integer linear programming based approach for optimal placement of different types of automation devices in distribution networks
    Popovic, Z.
    Brbaklic, B.
    Knezevic, S.
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2017, 148 : 136 - 146
  • [24] Multi-objective optimization of integrated energy system considering installation configuration
    Qiao, Yiyang
    Hu, Fan
    Xiong, Wen
    Guo, Zihao
    Zhou, Xiaoguang
    Li, Yajun
    [J]. ENERGY, 2022, 263
  • [25] Distributed Generation Placement Planning Modeling Feeder's Failure Rate and Customer's Load Type
    Rahmani-andebili, Mehdi
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2016, 63 (03) : 1598 - 1606
  • [26] Enhance the resilience of distribution system against direct and indirect effects of extreme winds using battery energy storage systems
    Rajabzadeh, Mohammad
    Kalantar, Mohsen
    [J]. SUSTAINABLE CITIES AND SOCIETY, 2022, 76
  • [27] Multi-objective optimisation-based active distribution system planning with reconfiguration, intermittent RES, and DSTATCOM
    Sannigrahi, Surajit
    Ghatak, Sriparna Roy
    Acharjee, Parimal
    [J]. IET RENEWABLE POWER GENERATION, 2019, 13 (13) : 2418 - 2429
  • [28] Potential of Mobile Energy Hubs for Enhancing Resilience of Electricity Distribution Systems
    Shahbazi, Amid
    Aghaei, Jamshid
    Niknam, Taher
    Ardeshiri, Masood
    Kavousi-Fard, Abdollah
    Shafie-khah, Miadreza
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2022, 213
  • [29] A joint automatic and manual switch placement within distribution systems considering operational probabilities of control sequences
    Shahsavari, Alireza
    Fereidunian, Alireza
    Mazhari, Seyed Mahdi
    [J]. INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2015, 25 (11): : 2745 - 2768
  • [30] Resilience improvement model of distribution network based on two-stage robust optimization
    Shen, Yutong
    Wang, Guoqing
    Zhu, Jianming
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2023, 223