Method: 2D/3D kV imaging and CBCT data using 6 degrees of freedom (6DoF) were compared to evaluate inter and intrafraction motion. Results: Results showed that intrafraction errors were low and interfraction levels were within institutional protocols. Conclusion: Con fidence was given to use low dose 2D/3D kV imaging to con firm daily patient set up errors, and to use pre-treatment CBCT only once weekly for additional imaging information. Implications for practice: Further research is necessary to assess other uncertainties, to enable the calculation of a margin and determining the feasibility of further reduction of this. Crown Copyright (c) 2024 Published by Elsevier Ltd on behalf of The College of Radiographers. All rights reserved.
引用
收藏
页码:1249 / 1257
页数:9
相关论文
共 50 条
  • [1] 2D-3D registration for brain radiation therapy using a 3D CBCT and a single limited field-of-view 2D kV radiograph
    Munbodh, R.
    Moseley, D. J.
    XVII INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY (ICCR 2013), 2014, 489
  • [2] A positioning QA procedure for 2D/2D (kV/MV) and 3D/3D (CT/CBCT) image matching for radiotherapy patient setup
    Guan, Huaiqun
    Hammoud, Rabih
    Yin, Fang-Fang
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2009, 10 (04): : 273 - 280
  • [3] 2D-3D registration for cranial radiation therapy using a 3D kV CBCT and a single limited field-of-view 2D kV radiograph
    Munbodh, Reshma
    Knisely, Jonathan P. S.
    Jaffray, David A.
    Moseley, Douglas J.
    MEDICAL PHYSICS, 2018, 45 (05) : 1794 - 1810
  • [4] A Study of 2D/3D with 3D/3D Registration Using KV/kV, KV/2.5X/6X
    Lin, S.
    Lovelock, D.
    Lim, S.
    Sillanpaa, J.
    Wang, D.
    Della-Biancia, C.
    Berry, S.
    Shasha, D.
    Kuo, H.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [5] Comparing 2D and 3D Imaging
    Ballantyne, Lauren
    JOURNAL OF VISUAL COMMUNICATION IN MEDICINE, 2011, 34 (03) : 138 - 141
  • [6] THE COMPARISON OF 2D/2D-KV AND CBCT TECHNIQUES DURING BREAST CANCER PATIENTS RADIOTHERAPY.
    Szczepanik, K.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S589 - S589
  • [7] 3D strain imaging using a rectilinear 2D array
    Awad, Samer I.
    Yen, Jesse T.
    ULTRASONIC IMAGING, 2007, 29 (04) : 220 - 230
  • [8] Estimation of 3D Imaging Dose for KV-MV-STR CBCT
    Shi, M.
    Jacobson, M.
    Myronakis, M.
    Ferguson, D.
    Lehmann, M.
    Baturin, P.
    Harris, T.
    Huber, P.
    Fueglistaller, R.
    Lozano, I. Valencia
    Williams, C.
    Morf, D.
    Berbeco, R.
    MEDICAL PHYSICS, 2020, 47 (06) : E532 - E532
  • [9] A seamless 2D/3D imaging workflow
    Quinlan, Kate
    BRITISH DENTAL JOURNAL, 2023, 234 (10) : 768 - 768
  • [10] A seamless 2D/3D imaging workflow
    British Dental Journal, 2023, 234 : 768 - 768