Condensation characteristics of flows in newly developed three-dimensional enhanced heat transfer tubes

被引:0
作者
Wang, Xiaobo [1 ]
Li, Wei [2 ]
Zhang, Le [1 ]
Wu, Junjie [1 ]
Zhang, Jianghui [1 ]
Kukulka, David J. [3 ]
He, Yan [1 ]
Wang, Zepeng [1 ]
Smith, Rick [4 ]
机构
[1] Qingdao Univ Sci & Technol, Dept Mech & Elect Engn, 99 Songling Rd, Qingdao 266061, Peoples R China
[2] Zhejiang Univ, Dept Energy Engn, 38 Zheda Rd, Hangzhou 310027, Peoples R China
[3] State Univ New York Coll Buffalo, 1300 Elmwood Ave, Buffalo, NY 14222 USA
[4] Vipertex, 658 Ohio St, Buffalo, NY USA
基金
中国国家自然科学基金;
关键词
Condensation flow; Enhanced heat transfer; Flow visualization; Flow pattern; Heat transfer coeffcient; MICROFIN; SMOOTH; R410A; R134A;
D O I
10.1016/j.energy.2024.132114
中图分类号
O414.1 [热力学];
学科分类号
摘要
Condensation heat transfer characteristics were studied experimentally in order to evaluate the heat transfer performance of horizontal copper heat transfer tubes (smooth and enhanced). Using R410A and R32 as refrigerants, condensation heat transfer experiments were carried out for a saturation temperature of 45 degrees C; inlet vapor quality of the tube was 0.8 and outlet quality was 0.2; refrigerant mass flow rate range was in the range from 68 to 371 kg/(m2 & sdot;s). Single-phase heat balance verification found that the heat loss is less than 6 %, with the deviation between single-phase experimental results and various correlations being less than 15 %. The condensation heat transfer coefficient increases with an increase in mass flow; as the mass flow rate increases, the turbulence of the liquid flow increases and the liquid film becomes thinner; thermal resistance is reduced and the heat transfer coefficient (HTC) increases. Experimental results determined that the performance factor ratio (enhanced tube/smooth tube) of the three-dimensional surfaces investigated here are greater than 1. Tubeside heat transfer enhancement factor (EF) of the HB/D tube is the highest (max 1.76); its performance is closely related to increasing fluid turbulence and improving drainage. Performance factor (PF) of the HB/D tube (max 1.38) is the highest for most of the flowrates. All this indicates excellent thermal performance. Flow model-based analysis was performed in order to develop a correlation for the condensation heat transfer coefficient and the pressure drop for the enhanced surface tubes. Both prediction models accurately predicted all data points within a limited margin of error.
引用
收藏
页数:12
相关论文
共 50 条
[41]   An improved heat transfer correlation for condensation inside inclined smooth tubes [J].
Adelaja, Adekunle O. ;
Ewim, Daniel R. E. ;
Dirker, Jaco ;
Meyer, Josua P. .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2020, 117
[42]   Development of Enhanced Heat Transfer Tubes [J].
Kukulka, David J. ;
Fuller, Kevin G. .
PRES 2010: 13TH INTERNATIONAL CONFERENCE ON PROCESS INTEGRATION, MODELLING AND OPTIMISATION FOR ENERGY SAVING AND POLLUTION REDUCTION, 2010, 21 :985-990
[43]   Comparative study for flow condensation heat transfer in horizontal enhanced tubes based on machine learning [J].
Li, Wei ;
Zhang, Gangan ;
Yang, Desong .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2024, 224
[44]   A CRITICAL REVIEW ON THE DETERMINATION OF CONVECTIVE HEAT TRANSFER COEFFICIENT DURING CONDENSATION IN SMOOTH AND ENHANCED TUBES [J].
Dalkilic, Ahmet Selim ;
Celen, Ali ;
Awad, Mohamed M. ;
Wongwises, Somchai .
PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE - 2013, VOL 2, 2014,
[45]   An Experimental Study of In-Tube Condensation and Evaporation Using Enhanced Heat Transfer (EHT) Tubes [J].
Zheng, Boren ;
Wang, Jiacheng ;
Guo, Yu ;
Kukulka, David John ;
Tang, Weiyu ;
Smith, Rick ;
Sun, Zhichuan ;
Li, Wei .
ENERGIES, 2021, 14 (04)
[46]   An Experimental Study of R134a Condensation Heat Transfer in Horizontal Smooth and Enhanced Tubes [J].
Li, Wei ;
Guo, Yu ;
Gu, Zong-Bao ;
Ma, Xiang ;
Ayub, Zahid ;
He, Yan ;
Kukulka, David J. .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2020, 142 (07)
[47]   Comparison of condensation and evaporation heat transfer on the outside of smooth and enhanced 1EHT tubes [J].
Kukulka, David J. ;
Smith, Rick ;
Li, Wei .
APPLIED THERMAL ENGINEERING, 2016, 105 :913-922
[48]   Heat transfer of staggered three-dimensional externally finned tube [J].
Ge M. ;
Zhao L. ;
Dai W. ;
Cai P. ;
Shu S. ;
Yang H. ;
Lü J. .
Huagong Xuebao/CIESC Journal, 2017, 68 (10) :3733-3738
[49]   Condensation heat transfer and flow characteristics of R-134a flowing through corrugated tubes [J].
Laohalertdecha, Suriyan ;
Wongwises, Somchai .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2011, 54 (11-12) :2673-2682
[50]   Experimental research on refrigerant condensation heat transfer and pressure drop characteristics in the horizontal microfin tubes [J].
Huang, Lihao ;
Tang, Cheng ;
Jiang, Jingde ;
Tao, Leren ;
Chen, Jianhong ;
Li, Xingjiang ;
Zheng, Zhigao ;
Tao, Hong .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2022, 135