Intraoperative Laser Speckle Contrast Imaging to Assess Vessel Flow in Neurosurgery: A Pilot Study

被引:3
|
作者
Goldberg, Johannes [1 ,2 ]
Miller, David R. [3 ]
Dimanche, Alexis [2 ,4 ]
Kissling, Cedric [1 ,2 ]
Mueller, Timothy [1 ,2 ]
Mueller, Mandy D. [1 ,2 ]
Jesse, Christopher Marvin [1 ,2 ]
Murek, Michael [1 ,2 ]
Bervini, David [1 ,2 ]
Dunn, Andrew K. [4 ]
Raabe, Andreas [1 ,2 ]
机构
[1] Univ Bern, Bern Univ Hosp, Inselspital, Dept Neurosurg, Freiburgstr 16, CH-3010 Bern, Switzerland
[2] Univ Bern, Bern Univ Hosp, Inselspital, Stroke Res Ctr Bern, Freiburgstr 16, CH-3010 Bern, Switzerland
[3] Dynam Light Inc, Austin, TX USA
[4] Univ Texas Austin, Dept Biomed Engn, Austin, TX USA
关键词
Cerebral blood flow; Cerebrovascular neurosurgery; Laser speckle contrast imaging; Indocyanine green angiography; AGREEMENT;
D O I
10.1227/neu.0000000000002776
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND OBJECTIVES: Laser speckle contrast imaging (LSCI) has emerged as a promising tool for assessment of vessel flow during neurosurgery. We aimed to investigate the feasibility of visualizing vessel flow in the macrocirculation with a new fully microscope-integrated LSCI system and assess the validity and objectivity of findings compared with fluorescence angiography (FA). METHODS: This is a single-center prospective observational study enrolling adult patients requiring microsurgical treatment for brain vascular pathologies or brain tumors. Three independent raters, blinded toward findings of FA, reviewed regions of interest (ROIs) placed in exposed vessels and target structures. The primary end point was the validity of LSCI for assessment of vessel flow as measured by the agreement with FA. The secondary end point was objectivity, measured as the inter-rater agreement of LSCI findings. RESULTS: During 18 surgical procedures, 23 observations using FA and LSCI were captured simultaneously. Using LSCI, vessel flow was assessable in 62 (86.1%) and not assessable in 10 (13.9%) ROIs. The agreement between LSCI and FA was 86.1%, with an agreement coefficient of 0.85 (95% CI: 0.75-0.94). Disagreement between LSCI and FA was observed in the 10 ROIs that were not assessable. The agreement between ROIs that were assessable using LSCI and FA was 100%. The inter-rater agreement of LSCI findings was 87.9%, with an agreement coefficient of 0.86 (95% CI: 0.79-0.94). CONCLUSION: Fully microscope-integrated LSCI is feasible and has a high potential for clinical utility. Because of its characteristics, LSCI can be viewed as a full-field visual micro-Doppler that can be used as a complementary method to FA for assessing vessel flow during neurosurgery. Despite technical limitations related to the early development phase of the fully microscope-integrated system, we demonstrated reasonable validity and objectivity of findings compared with FA. Further research and refinement of the system may enhance its value in neurosurgical applications.
引用
收藏
页码:983 / 992
页数:10
相关论文
共 50 条
  • [21] Intraoperative laser speckle contrast imaging improves the stability of rodent middle cerebral artery occlusion model
    Yuan, Lu
    Li, Yao
    Li, Hangdao
    Lu, Hongyang
    Tong, Shanbao
    JOURNAL OF BIOMEDICAL OPTICS, 2015, 20 (09)
  • [22] Local scattering property scales flow speed estimation in laser speckle contrast imaging
    Miao, Peng
    Chao, Zhen
    Feng, Shihan
    Yu, Hang
    Ji, Yuanyuan
    Li, Nan
    Thakor, Nitish V.
    LASER PHYSICS LETTERS, 2015, 12 (07)
  • [23] Expanding applications, accuracy, and interpretation of laser speckle contrast imaging of cerebral blood flow
    Kazmi, S. M. Shams
    Richards, Lisa M.
    Schrandt, Christian J.
    Davis, Mitchell A.
    Dunn, Andrew K.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2015, 35 (07): : 1076 - 1084
  • [24] Laser speckle contrast imaging of cerebral blood flow of newborn mice at optical clearing
    Timoshina, Polina A.
    Zinchenko, Ekaterina M.
    Tuchina, Dania K.
    Sagatova, Madina M.
    Semyachkina-Glushkovskaya, Oxana V.
    Tuchin, Valery V.
    SARATOV FALL MEETING 2016 OPTICAL TECHNOLOGIES IN BIOPHYSICS AND MEDICINE XVIII, 2017, 10336
  • [25] Laser Speckle Contrast Imaging for Monitoring Changes in Microvascular Blood Flow
    Ambrus, Rikard
    Strandby, Rune B.
    Svendsen, Lars Bo
    Achiam, Michael P.
    Steffensen, John F.
    Svendsen, Morten Bo Sondergaard
    EUROPEAN SURGICAL RESEARCH, 2016, 56 (3-4) : 87 - 96
  • [26] Laser speckle contrast imaging is sensitive to advective flux
    Khaksari, Kosar
    Kirkpatrick, Sean J.
    JOURNAL OF BIOMEDICAL OPTICS, 2016, 21 (07)
  • [27] Clinical applications of laser speckle contrast imaging: a review
    Heeman, Wido
    Steenbergen, Wiendelt
    van Dam, Gooitzen M.
    Boerma, E. Christiaan
    JOURNAL OF BIOMEDICAL OPTICS, 2019, 24 (08)
  • [28] Dynamic Alterations in Blood Flow in Glaucoma Measured with Laser Speckle Contrast Imaging
    Vinnett, Alfred
    Kandukuri, Jayanth
    Le, Christopher
    Cho, Kyoung-A
    Sinha, Avigyan
    Asanad, Samuel
    Thompson, Ginger
    Chen, Victoria
    Rege, Abhishek
    Saeedi, Osamah J.
    OPHTHALMOLOGY GLAUCOMA, 2022, 5 (03): : 250 - 261
  • [29] Investigating the depth-sensitivity of laser speckle contrast imaging in flow phantoms
    Young, Anthony
    Vishwanath, Karthik
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [30] Vertically Polarized Laser Speckle Contrast Imaging to Monitor Blood Flow in Pulp
    Xu, Fenfen
    Xie, Chengfeng
    Zhang, Yubao
    Shi, Gang
    Shi, Jiulin
    Xu, Xiaojun
    Zhao, Youjiang
    Zhu, Yirui
    He, Xingdao
    JOURNAL OF MODERN OPTICS, 2021, 68 (20) : 1075 - 1082