Trueness of artificial teeth for CAD-CAM complete dentures fabricated with additive manufacturing implementing different denture base-tooth offset values: An in vitro study

被引:1
|
作者
Neena, Akram F. [1 ]
Abd-Ellah, Mervat E. [1 ]
机构
[1] Univ Alexandria, Fac Dent, Dept Prosthodont, Champlion St, Alexandria, Egypt
关键词
TECHNOLOGY; ACCURACY;
D O I
10.1016/j.prosdent.2024.01.001
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Computer -aided design and computer -aided manufacturing (CAD -CAM) removable dentures have become popular. However, evaluations of the effect of denture base -tooth offset (DTO) values on the trueness of artificial teeth are lacking. Purpose. The purpose of this in vitro study was to digitally measure the trueness of the artificial teeth of CAD -CAM dentures fabricated with additive manufacturing using different DTO values and to determine the most accurate DTO value. Material and methods. Seven study groups were formulated based on different DTO values, and 6 maxillary complete dentures were assigned to each group (n=42). A design software program was used to export the monoblock denture as control, the artificial teeth, and 7 different designs of denture bases with DTO values of 0.00, 0.01, 0.03, 0.05, 0.10, 0.15, and 0.20 mm. Denture bases were printed in denture base resin (Denture base RP; formlabs), artificial teeth were printed in tooth -shade resin (Denture teeth A2; formlabs), and both were then assembled and polymerized together. The dentures were scanned (InEos X5; Dentsply Sirona), scan data were imported in a measuring software program (GOM Inspect; GOM GmbH), and registration using local best fit was performed to align data. Color -coded maps for the surface comparison of each denture with the control denture scan were generated. Fitting center points were constructed for each artificial tooth, which were compared with their corresponding points on the data of the control scan. Multiple pairwise comparisons were performed after 1 -way ANOVA to quantify and statistically evaluate the deviation values (alpha=.05). Results. The 0.10 -mm DTO group showed the lowest values when comparing artificial tooth deviations both individually and as types. On comparing the average deviations, statistically significant differences were identified among the 7 groups ( P<.001). A nonstatistically significant difference was identified when the 0.10- and 0.05 -mm DTO groups were compared. Lower deviation values were found in the premolars compared with the molars, in the incisors compared with the canines, and in posterior artificial teeth compared with anterior teeth. Conclusions. The 0.10 -mm DTO value showed the highest trueness for the artificial teeth compared with the other DTO values tested in this study. The 0.05 -mm DTO value is an alternative to the 0.10 -mm DTO value for CAD -CAM dentures constructed by additive manufacturing. Anterior teeth of a CAD -CAM denture showed higher deviation values compared with posterior teeth.
引用
收藏
页码:705e1 / 705e7
页数:7
相关论文
共 6 条
  • [1] In vitro evaluation of basal shapes and offset values of artificial teeth for CAD/CAM complete dentures
    Yamamoto, Shinta
    Kanazawa, Manabu
    Hirayama, Daisuke
    Nakamura, Toshinari
    Arakida, Toshio
    Minakuchi, Shunsuke
    COMPUTERS IN BIOLOGY AND MEDICINE, 2016, 68 : 84 - 89
  • [2] Trueness and precision of artificial teeth in CAD-CAM milled complete dentures with custom disks
    Soeda, Yumika
    Kanazawa, Manabu
    Hada, Tamaki
    Arakida, Toshio
    Iwaki, Maiko
    Minakuchi, Shunsuke
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (04) : 695 - 701
  • [3] Evaluation of trueness in a denture base fabricated by using CAD-CAM systems and adaptation to the socketed surface of denture base: An in vitro study
    You, Seung-Min
    You, Seung-Gyu
    Lee, Beom-Il
    Kim, Ji-Hwan
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (01) : 108 - 114
  • [4] Effects of offset values for artificial teeth positions in CAD/CAM complete denture
    Yamamoto, Shinta
    Kanazawa, Manabu
    Iwaki, Maiko
    Jokanovic, Ana
    Minakuchi, Shunsuke
    COMPUTERS IN BIOLOGY AND MEDICINE, 2014, 52 : 1 - 7
  • [5] Evaluation of the occlusal trueness among 3-Dimensionally printed CAD-CAM complete dentures with different socket designs and teeth splinting assemblies
    Rowan Mohamed Abdelsadek Mohamed Sallam
    Nayrouz Adel Metwally
    Mohamed Moataz Khamis
    BMC Oral Health, 25 (1)
  • [6] Evaluation of the Effect of Different Construction Techniques of CAD-CAM Milled, 3D-Printed, and Polyamide Denture Base Resins on Flexural Strength: An In Vitro Comparative Study
    Zeidan, Ahmed Abd El-Latif
    Sherif, Ahmed Fadlallah
    Baraka, Yasser
    Abualsaud, Reem
    Abdelrahim, Ramy Abdallah
    Gad, Mohammed M.
    Helal, Mohamed A.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (01): : 77 - 82