Response Control of SDOF System with Inerter-Assisted Tuned Liquid Sloshing Damper

被引:2
作者
Suthar, Sameer J. [1 ]
机构
[1] Indian Inst Technol, Dept Civil Engn, Mumbai 400076, Maharashtra, India
关键词
Tuned liquid dampers (TLDs); Liquid sloshing; Inerter; Passive dampers; Vibration control; WIND-INDUCED VIBRATION; EARTHQUAKE RESPONSE; SEISMIC RESPONSE; MASS; SUPPRESSION; PERFORMANCE; BUILDINGS; REDUCTION; STIFFNESS;
D O I
10.1061/JENMDT.EMENG-7618
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
In the present study, an inerter is introduced between a tuned liquid sloshing damper (TLSD) and a single degree of freedom (SDOF) system. The resulting vibration control system is known as an inerter-assisted tuned liquid sloshing damper (IA-TLSD). The liquid sloshing inside TLSD was modeled using nonlinear shallow water wave theory. The governing equations of motion of the combined SDOF system and IA-TLSD are formulated. Design parameters of IA-TLSD were obtained numerically, and its behavior and working principles have been studied. The response of the combined system under harmonic base excitation was computed numerically using the Newmark-beta method. It was found that the use of a larger inerter ratio does not help much to improve the performance of IA-TLSD for given design parameters. To retain enough liquid sloshing in IA-TLSD, a lower value of inerter ratio is suggested. With an optimal design, IA-TLSD has much better control effectiveness as compared to the TLSD with the same mass ratio. Thus, IA-TLSD can be used for vibration control of structures and has the potential for wind-induced response control of tall buildings.
引用
收藏
页数:11
相关论文
共 60 条
[1]  
Banavalkar P. V., 1991, Modern Steel Constr, V31, P13
[2]  
BANAVALKAR PV, 1990, J WIND ENG IND AEROD, V36, P213
[3]  
Banerji P, 2000, EARTHQUAKE ENG STRUC, V29, P587, DOI 10.1002/(SICI)1096-9845(200005)29:5<587::AID-EQE926>3.0.CO
[4]  
2-I
[5]   Earthquake vibration control of structures using hybrid mass liquid damper [J].
Banerji, Pradipta ;
Samanta, Avik .
ENGINEERING STRUCTURES, 2011, 33 (04) :1291-1301
[6]  
Chopra A. K., 2007, Dynamics of structuresTheory and applications to earthquake engineering, V2nd ed.
[7]  
Colaco J. P., 2005, P CTBUH 7 WORLD C NE, P1
[8]  
Den Hartog J.P., 1985, Mechanical Vibrations, DOI DOI 10.1038/161503C0
[9]   Wind-Induced Vibration Mitigation in Tall Buildings Using the Tuned Mass-Damper-Inerter [J].
Giaralis, Agathoklis ;
Petrini, Francesco .
JOURNAL OF STRUCTURAL ENGINEERING, 2017, 143 (09)
[10]   Numerical studies on the application of tuned liquid dampers with screens to control seismic response of structures [J].
Halabian, A. M. ;
Torki, M. .
STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2011, 20 (02) :121-150