Efficacy of Subthreshold Micropulse Laser for Central Serous Chorioretinopathy

被引:2
|
作者
Fasler, Katrin [1 ]
Turgut, Ferhat [2 ,3 ,4 ,9 ]
Gunzinger, Jeanne Martine [1 ,5 ]
Sommer, Chiara [1 ,2 ,4 ]
Muth, Daniel Rudolf [1 ,6 ]
Kinzl, Stephan [2 ,4 ]
Nilius, Henning [7 ,8 ]
Zweifel, Sandrine [1 ]
Somfai, Gabor Mark [2 ,4 ,9 ]
机构
[1] Univ Zurich, Univ Hosp Zurich, Dept Ophthalmol, Frauenklin Str 24, CH-8091 Zurich, Switzerland
[2] Stadtspital Zurich Triemli, Ophthalmol, Birmensdorferstr 497, CH-8063 Zurich, Switzerland
[3] Gutblick Res, Ophthalmol, Pfaffikon, Switzerland
[4] Spross Res Inst, Zurich, Switzerland
[5] Hunter New England Hlth, New Lambton Hts, NSW, Australia
[6] Karolinska Inst, Dept Clin Neurosci, Div Eye & Vis, Stockholm, Sweden
[7] Bern Univ Hosp, Dept Clin Chem, Inselspital, Bern, Switzerland
[8] Univ Bern, Grad Sch Hlth Sci, Bern, Switzerland
[9] Semmelweis Univ, Dept Ophthalmol, Budapest, Hungary
关键词
central serous chorioretinopathy; subthreshold micropulse laser; photodynamic therapy; Chorioretinopathia centralis serosa; Subthreshold Micropulse-Laser; photodynamische Therapie;
D O I
10.1055/a-2229-2298
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To evaluate the efficacy of a subthreshold micropulse laser (SML) in patients with central serous chorioretinopathy (CSCR). Methods Retrospective clinical study conducted at the Departments of Ophthalmology at a university and a municipal hospital in Zurich, Switzerland. We enrolled acute and chronic CSCR patients with persistent subretinal fluid (SRF) treated with SML. Two treatment protocols (fluorescein/indocyanine green angiography or optical coherence tomography guided) were evaluated for efficacy after 3 and 6 months. The primary outcomes of the study were reduction and percentage of eyes with complete resolution of SRF 3 and 6 months after SML treatment. Secondary endpoints included changes in central subfield thickness (CST) and visual acuity (VA) after 3 and 6 months. Results The study involved 37 eyes (35 patients, 48.6% chronic). A statistically significant reduction in SRF height and CST could be shown, irrespective of SRF duration, type of CSCR, or chosen guidance after 3 and 6 months: SRF - 40 mu m (p < 0.01), CST - 52 <mu>m (p < 0.01). Percentage of eyes with complete resolution of fluid at 3 and 6 months after SML were 24.3 and 21.6%, respectively. No statistically significant functional improvement (VA) could be shown. Multivariable regression and linear mixed regression analyses did not identify statistically significant differences in SRF reduction, CMT change, or VA improvement with respect to the type of CSCR or the treatment plan used (p > 0.05). Conclusion The effectiveness of SML in CSCR is under continuous debate. Our study findings demonstrate structural but only little functional changes with SML. In view of the shortage of verteporfin for photodynamic therapy, SML remains an important therapeutic option for CSCR patients.
引用
收藏
页码:489 / 495
页数:7
相关论文
共 50 条
  • [21] Comparison of the efficacy and safety of subthreshold micropulse laser with photodynamic therapy for the treatment of chronic central serous chorioretinopathy A meta-analysis
    Wu, Zhizhong
    Wang, Huixing
    An, Junsheng
    MEDICINE, 2021, 100 (17) : E25722
  • [22] Evaluation of changes in macular structures after subthreshold micropulse laser therapy on chronic central serous chorioretinopathy
    Liu, Lijun
    Xu, Qian
    Song, Xian
    Zhao, Yuqing
    Zhang, Yu
    Qu, Yi
    LASERS IN MEDICAL SCIENCE, 2024, 39 (01)
  • [23] Comparing Half-Dose Photodynamic Therapy with Subthreshold Micropulse Laser for the Treatment of Central Serous Chorioretinopathy
    Brelen, Marten E.
    Ho, Mary
    Li, Sophia
    Ng, Danny S. C.
    Yip, Yolanda W. Y.
    Lee, Wing Sze
    Chen, Li Jia
    Young, Alvin L.
    Tham, Clement C.
    Pang, Chi Pui
    OPHTHALMOLOGY RETINA, 2024, 8 (05): : 490 - 498
  • [24] The safe lowest effective power of subthreshold micropulse laser treatment in Chinese patients with acute or chronic central serous chorioretinopathy
    Xie, Ting
    Li, Wangting
    Wang, Linli
    Ning, Jiafeng
    Li, Zhi
    Chen, Yulei
    Lin, Xifeng
    Du, Shaolin
    Chen, Qingshan
    FRONTIERS IN MEDICINE, 2024, 11
  • [25] Prognostic factors of visual outcome in central serous chorioretinopathy treated with subthreshold micropulse laser therapy
    Huang, Ying
    Li, Guang
    Ge, Lina
    Lin, Bing
    LASERS IN MEDICAL SCIENCE, 2024, 39 (01)
  • [26] Comparative efficacy of subthreshold micropulse laser therapy for chronic central serous chorioretinopathy: Navigated vs. non-navigated approach
    Karapapak, M.
    Ozal, E.
    Ermis, S.
    Ozal, S. A.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2025, 48 (05):
  • [27] Crossover to 689 nm laser therapy after poor responsiveness to subthreshold micropulse laser for chronic central serous chorioretinopathy
    Zhang, Yue
    Wang, Jianing
    Zhang, Jinrong
    Song, Shuang
    Gu, Xiaoya
    Yu, Xiaobing
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2024, 50
  • [28] Comparison of two protocols of subthreshold micropulse yellow laser treatment for non-resolving central serous chorioretinopathy
    Beniwal, Abhijeet
    Shaikh, Nawazish
    Chawla, Rohan
    Azad, Shorya Vardhan
    Kumar, Vinod
    Vohra, Rajpal
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (09) : 3341 - 3345
  • [29] Functional Outcomes and Safety Profile of Trans-Foveal Subthreshold Micropulse Laser in Persistent Central Serous Chorioretinopathy
    Kiraly, Peter
    Habjan, Maja Sustar
    Smrekar, Jaka
    Mekjavic, Polona Jaki
    LIFE-BASEL, 2023, 13 (05):
  • [30] Crossover to PDT after the unsuccessful micropulse laser treatment of central serous chorioretinopathy
    Gawecki, Maciej
    Kicinski, Krzysztof
    Grzybowski, Andrzej
    ADVANCES IN OPHTHALMOLOGY PRACTICE AND RESEARCH, 2024, 4 (01): : 32 - 38