Reagent-free anti-fouling electrochemical immunosensor based on AL-BSA/ AuNPs/PANI coating for the point-of-care detection of C-reactive protein in plasma and whole blood

被引:4
作者
Lu, Tai-Cheng [1 ]
Lin, Yi-Ting [1 ]
Xiao, Wen-Biao [2 ]
Qiu, Qing-Zhen [1 ]
Tian, Hui-Yun [3 ]
Lei, Yun [1 ]
Liu, Ai-Lin [1 ]
机构
[1] Fujian Med Univ, Sch Pharm, Dept Pharmaceut Anal, Higher Educ Key Lab Nano Biomed Technol Fujian Pro, Fuzhou 350122, Peoples R China
[2] Fujian Med Univ, Affiliated Hosp 1, Dept Crit Care Med, Fuzhou, Fujian, Peoples R China
[3] Fujian Med Univ, Affiliated Union Hosp, Fujian Inst Hematol, Fuzhou 350000, Peoples R China
基金
中国国家自然科学基金;
关键词
C -reactive protein; Anti-fouling coating; Electrochemical immunosensor; Cauliflower gold nanoparticles; Whole blood tests; BIOSENSOR;
D O I
10.1016/j.bios.2024.116667
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Developing the portable CRP detection technologies that are suitable for point-of-care (POC) and primary care management is of utmost importance, and advancing the electrochemical immunosensors hold promise for POC implementation. Nevertheless, non-specific adsorption of numerous interfering proteins in complex biological media contaminates immunosensors, thereby restricting the reliability in detection efficacy. In this study, a three-dimensional flower-leaf shape amyloid bovine serum albumin/gold nanoparticles/polyaniline (AL-BSA/ AuNPs/PANI) coating on the surface of the electrode was developed, which demonstrated strong anti-adsorption properties against bovine serum albumin, plasma, and cells. The immunosensor exhibited a good linear relationship to CRP response, featuring a detection limit of 0.09 mu g/mL, consistent with clinical reference range. In addition, the CRP immunosensor demonstrated excellent specificity in other inflammation-related proteins and commendable anti-interference performance for CRP detection in plasma and whole blood tests. Importantly, by combining the development of a USB flash disk-type portable electrochemical workstation with a reagent-free mode, the developed CRP electrochemical immunosensor delivered ideal results in clinical samples. The antifouling performance, sensitivity and specificity of the immunosensor, as well as its flexible test modes in clinical samples, provide important scientific basis for developing POC detection technologies of vital biomarkers in complex biological media.
引用
收藏
页数:10
相关论文
共 2 条
  • [1] Rapid C-reactive protein determination in whole blood with a White Light Reflectance Spectroscopy label-free immunosensor for Point-of-Care applications
    Koukouvinos, Georgios
    Goustouridis, Dimitrios
    Misiakos, Konstantinos
    Kakabakos, Sotirios
    Raptis, Ioannis
    Petrou, Panagiota
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 260 : 282 - 288
  • [2] An array-based electrochemical magneto-immunosensor for early neonatal sepsis diagnostic: Fast and accurate determination of C-reactive protein in whole blood and plasma samples
    Molinero-Fernandez, Agueda
    Moreno-Guzman, Maria
    Lopez, Miguel angel
    Escarpa, Alberto
    MICROCHEMICAL JOURNAL, 2020, 157