Monte Carlo-based Investigation of Absorbed-dose Energy Dependence of Thermoluminescent Dosimeters in Therapeutic Proton and Carbon Ion Beams

被引:0
|
作者
Chattaraj, Arghya [1 ,2 ]
Mishra, Subhalaxmi [1 ]
Selvam, T. Palani [1 ,2 ]
机构
[1] Bhabha Atom Res Ctr, Hlth Safety & Environm Grp, Radiol Phys & Advisory Div, Mumbai 400085, Maharashtra, India
[2] Homi Bhabha Natl Inst, Mumbai, Maharashtra, India
关键词
Carbon ions; Monte Carlo; protons; thermoluminescent dosimeter response; HEAVY-IONS; DETECTORS; RESPONSES; FLUKA;
D O I
10.4103/jmp.jmp_25_24
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The present study is aimed at calculating relative absorbed-dose energy response correction (R) of commonly used thermoluminescent dosimeters (TLDs) such as LiF, Li2B4O7, and Al2O3 as a function of depth in water for protons (50-250 MeV/n) and carbon ion (80-480 MeV/n) beams using Monte Carlo-based FLUKA code.Materials and Methods: On-axis depth-dose profiles in water are calculated for protons (50-250 MeV/n) and carbon ion (80-480 MeV/n) beams using FLUKA code. For the calculation of R, selective depths are chosen based on the depth-dose profiles. In the simulations, the TLDs of dimensions 1 mm x 1 mm x 1 mm are positioned at the flat, dose gradient, and Bragg peak regions of the depth-dose profile. Absorbed dose to detector was calculated within the TLD material. In the second step, TLD voxels were replaced by water voxel of similar dimension and absorbed dose to water was scored.Results: The study reveals that for both proton and carbon ion beams, the value of R differs from unity significantly at the Bragg peak position and is close to unity at the flat region for the investigated TLDs. The calculated R value is sensitive to depth in water, beam energy, type of ion beam, and type of TLD.Discussion: For accurate dosimetry of protons and carbon ion beams using TLDs, the response of the TLD should be corrected to account for its absorbed-dose energy dependence.
引用
收藏
页码:148 / 154
页数:7
相关论文
共 23 条
  • [21] Monte Carlo Calculation for Production Cross- Sections of Projectile's Isotopes from Therapeutic Carbon and Helium Ion Beams in Different Materials
    Nizam, Quazi Muhammad Rashed
    Ahmed, Asif
    Ahmed, Iftekhar
    JOURNAL OF RADIATION PROTECTION AND RESEARCH, 2023, 48 (04): : 204 - 212
  • [22] Clinical dose assessment for scanned carbon-ion radiotherapy using linear energy transfer measurements and Monte Carlo simulations
    Nakaji, Taku
    Kanai, Tatsuaki
    Takashina, Masaaki
    Matsumura, Akihiko
    Osaki, Kohei
    Yagi, Masashi
    Tsubouchi, Toshiro
    Hamatani, Noriaki
    Ogawa, Kazuhiko
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (24)
  • [23] Gate/Geant4-based Monte Carlo simulation for calculation of dose distribution of 400 MeV/u carbon ion beam and fragments in water
    Ou, Hai-Feng
    Zhang, Bin
    Zhao, Shu-Jun
    NUCLEAR SCIENCE AND TECHNIQUES, 2016, 27 (04)