Optimized Enzyme-Linked Immunosorbent Assay for Anti-PEG Antibody Detection in Healthy Donors and Patients Treated with PEGylated Liposomal Doxorubicin

被引:1
作者
Li, Yue [1 ]
Ettah, Utibeabasi [1 ]
Jacques, Sarah [1 ]
Gaikwad, Hanmant [1 ,2 ]
Monte, Andrew [3 ]
Dylla, Layne [3 ]
Guntupalli, Saketh [4 ]
Moghimi, S. Moein [1 ,2 ,5 ,6 ]
Simberg, Dmitri [1 ,2 ]
机构
[1] Univ Colorado, Skaggs Sch Pharm & Pharmaceut Sci, Dept Pharmaceut Sci, Anschutz Med Campus, Aurora, CO 80045 USA
[2] Univ Colorado, Colorado Ctr Nanomed & Nanosafety, Anschutz Med Campus, Aurora, CO 80045 USA
[3] Univ Colorado, Dept Emergency Med, Anschutz Med Campus, Aurora, CO 80045 USA
[4] Univ Colorado, Dept Obstet & Gynecol, Div Gynecol Oncol, Sch Med,Anschutz Med Campus, Aurora, CO 80045 USA
[5] Newcastle Univ, Sch Pharm, Newcastle Upon Tyne NE1 7RU, England
[6] Newcastle Univ, Translat & Clin Res Inst, Fac Hlth & Med Sci, Newcastle Upon Tyne NE2 4HH, England
关键词
PEG; ELISA; Doxil; PEGylated liposomaldoxorubicin; patients; specific; ACCELERATED BLOOD CLEARANCE; POLYETHYLENE-GLYCOL PEG; ANTIPHOSPHOLIPID SYNDROME; PREEXISTING IGG; PROTEINS;
D O I
10.1021/acs.molpharmaceut.4c00278
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
There is considerable interest in quantifying anti-PEG antibodies, given their potential involvement in accelerated clearance, complement activation, neutralization, and acute reactions associated with drug delivery systems. Published and commercially available anti-PEG enzyme-linked immunosorbent assays (ELISAs) differ significantly in terms of reagents and conditions, which could be confusing to users who want to perform in-house measurements. Here, we optimize the ELISA protocol for specific detection of anti-PEG IgG and IgM in sera from healthy donors and in plasma from cancer patients administered with PEGylated liposomal doxorubicin. The criterion of specificity is the ability of free PEG or PEGylated liposomes to inhibit the ELISA signals. We found that coating high-binding plates with monoamine methoxy-PEG(5000), as opposed to bovine serum albumin-PEG(20000), and blocking with 1% milk, as opposed to albumin or lysozyme, significantly improve the specificity, with over 95% of the signal being blocked by competition. Despite inherent between-assay variability, setting the cutoff value of the optical density at the 80th percentile consistently identified the same subjects. Using the optimized assay, we longitudinally measured levels of anti-PEG IgG/IgM in cancer patients before and after the PEGylated liposomal doxorubicin chemotherapy cycle (1 month apart, three cycles total). Antibody titers did not show any increase but rather a decrease between treatment cycles, and up to 90% of antibodies was bound to the infused drug. This report is a step toward harmonizing anti-PEG assays in human subjects, emphasizing the cost-effectiveness and optimized specificity.
引用
收藏
页码:3053 / 3060
页数:8
相关论文
共 32 条
  • [31] Analysis of Pre-existing IgG and IgM Antibodies against Polyethylene Glycol (PEG) in the General Population
    Yang, Qi
    Jacobs, Timothy M.
    McCallen, Justin D.
    Moore, Dominic T.
    Huckaby, Justin T.
    Edelstein, Jasmine N.
    Lai, Samuel K.
    [J]. ANALYTICAL CHEMISTRY, 2016, 88 (23) : 11804 - 11812
  • [32] Anti-PEG immunity: emergence, characteristics, and unaddressed questions
    Yang, Qi
    Lai, Samuel K.
    [J]. WILEY INTERDISCIPLINARY REVIEWS-NANOMEDICINE AND NANOBIOTECHNOLOGY, 2015, 7 (05) : 655 - 677