Optimized Enzyme-Linked Immunosorbent Assay for Anti-PEG Antibody Detection in Healthy Donors and Patients Treated with PEGylated Liposomal Doxorubicin

被引:1
作者
Li, Yue [1 ]
Ettah, Utibeabasi [1 ]
Jacques, Sarah [1 ]
Gaikwad, Hanmant [1 ,2 ]
Monte, Andrew [3 ]
Dylla, Layne [3 ]
Guntupalli, Saketh [4 ]
Moghimi, S. Moein [1 ,2 ,5 ,6 ]
Simberg, Dmitri [1 ,2 ]
机构
[1] Univ Colorado, Skaggs Sch Pharm & Pharmaceut Sci, Dept Pharmaceut Sci, Anschutz Med Campus, Aurora, CO 80045 USA
[2] Univ Colorado, Colorado Ctr Nanomed & Nanosafety, Anschutz Med Campus, Aurora, CO 80045 USA
[3] Univ Colorado, Dept Emergency Med, Anschutz Med Campus, Aurora, CO 80045 USA
[4] Univ Colorado, Dept Obstet & Gynecol, Div Gynecol Oncol, Sch Med,Anschutz Med Campus, Aurora, CO 80045 USA
[5] Newcastle Univ, Sch Pharm, Newcastle Upon Tyne NE1 7RU, England
[6] Newcastle Univ, Translat & Clin Res Inst, Fac Hlth & Med Sci, Newcastle Upon Tyne NE2 4HH, England
关键词
PEG; ELISA; Doxil; PEGylated liposomaldoxorubicin; patients; specific; ACCELERATED BLOOD CLEARANCE; POLYETHYLENE-GLYCOL PEG; ANTIPHOSPHOLIPID SYNDROME; PREEXISTING IGG; PROTEINS;
D O I
10.1021/acs.molpharmaceut.4c00278
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
There is considerable interest in quantifying anti-PEG antibodies, given their potential involvement in accelerated clearance, complement activation, neutralization, and acute reactions associated with drug delivery systems. Published and commercially available anti-PEG enzyme-linked immunosorbent assays (ELISAs) differ significantly in terms of reagents and conditions, which could be confusing to users who want to perform in-house measurements. Here, we optimize the ELISA protocol for specific detection of anti-PEG IgG and IgM in sera from healthy donors and in plasma from cancer patients administered with PEGylated liposomal doxorubicin. The criterion of specificity is the ability of free PEG or PEGylated liposomes to inhibit the ELISA signals. We found that coating high-binding plates with monoamine methoxy-PEG(5000), as opposed to bovine serum albumin-PEG(20000), and blocking with 1% milk, as opposed to albumin or lysozyme, significantly improve the specificity, with over 95% of the signal being blocked by competition. Despite inherent between-assay variability, setting the cutoff value of the optical density at the 80th percentile consistently identified the same subjects. Using the optimized assay, we longitudinally measured levels of anti-PEG IgG/IgM in cancer patients before and after the PEGylated liposomal doxorubicin chemotherapy cycle (1 month apart, three cycles total). Antibody titers did not show any increase but rather a decrease between treatment cycles, and up to 90% of antibodies was bound to the infused drug. This report is a step toward harmonizing anti-PEG assays in human subjects, emphasizing the cost-effectiveness and optimized specificity.
引用
收藏
页码:3053 / 3060
页数:8
相关论文
共 32 条
  • [1] Abu Lila AS, 2018, WOODH PUBL SER BIOM, P51, DOI 10.1016/B978-0-08-101750-0.00003-9
  • [2] Antibody against poly(ethylene glycol) adversely affects PEG-asparaginase therapy in acute lymphoblastic leukemia patients
    Armstrong, Jonathan K.
    Hempel, Georg
    Koling, Susanne
    Chan, Linda S.
    Fisher, Timothy
    Meiselman, Herbert J.
    Garratty, George
    [J]. CANCER, 2007, 110 (01) : 103 - 111
  • [3] Anti-PEG antibodies before and after a first dose of Comirnaty? (mRNA-LNP-based SARS-CoV-2 vaccine)
    Bavli, Yaelle
    Chen, Bing-Mae
    Gross, Guy
    Hershko, Alon
    Turjeman, Keren
    Roffler, Steve
    Barenholz, Yechezkel
    [J]. JOURNAL OF CONTROLLED RELEASE, 2023, 354 : 316 - 322
  • [4] Polyethylene Glycol Immunogenicity: Theoretical, Clinical, and Practical Aspects of Anti-Polyethylene Glycol Antibodies
    Chen, Bing-Mae
    Cheng, Tian-Lu
    Roffler, Steve R.
    [J]. ACS NANO, 2021, 15 (09) : 14022 - 14048
  • [5] Measurement of Pre-Existing IgG and IgM Antibodies against Polyethylene Glycol in Healthy Individuals
    Chen, Bing-Mae
    Su, Yu-Cheng
    Chang, Chia-Jung
    Burnouf, Pierre-Alain
    Chuang, Kuo-Hsiang
    Chen, Chien-Hsiun
    Cheng, Tian-Lu
    Chen, Yuan-Tsong
    Wu, Jer-Yuarn
    Roffler, Steve R.
    [J]. ANALYTICAL CHEMISTRY, 2016, 88 (21) : 10661 - 10666
  • [6] Premature Drug Release from Polyethylene Glycol (PEG)-Coated Liposomal Doxorubicin via Formation of the Membrane Attack Complex
    Chen, Even
    Chen, Bing-Mae
    Su, Yu-Cheng
    Chang, Yuan-Chih
    Cheng, Tian-Lu
    Barenholz, Yechezekel
    Roffler, Steve R.
    [J]. ACS NANO, 2020, 14 (07) : 7808 - 7822
  • [7] Chen FF, 2017, NAT NANOTECHNOL, V12, P387, DOI [10.1038/nnano.2016.269, 10.1038/NNANO.2016.269]
  • [8] Accelerated clearance of polyethylene glycol-modified proteins by anti-polyethylene glycol IgM
    Cheng, TL
    Wu, PY
    Wu, MF
    Chern, JW
    Roffler, SR
    [J]. BIOCONJUGATE CHEMISTRY, 1999, 10 (03) : 520 - 528
  • [9] Anti-PEG antibodies enriched in the protein corona of PEGylated nanocarriers impact the cell uptake
    Deuker, Mareike F. S.
    Mailaender, Volker
    Morsbach, Svenja
    Landfester, Katharina
    [J]. NANOSCALE HORIZONS, 2023, 8 (10) : 1377 - 1385
  • [10] A generic method for the detection of polyethylene glycol specific IgG and IgM antibodies in human serum
    Ehlinger, Christopher
    Spear, Nathan
    Doddareddy, Rajitha
    Shankar, Gopi
    Schantz, Allen
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 2019, 474