In Vivo Knee Contact Force Prediction Using Patient-Specific Musculoskeletal Geometry in a Segment-Based Computational Model

被引:46
作者
Ding, Ziyun [1 ]
Nolte, Daniel [1 ]
Tsang, Chui Kit [1 ]
Cleather, Daniel J. [2 ]
Kedgley, Angela E. [1 ]
Bull, Anthony M. J. [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Bioengn, London SW7 2AZ, England
[2] St Marys Univ, Sch Sport Hlth & Appl Sci, Waldegrave Rd, Twickenham TW1 4SX, England
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2016年 / 138卷 / 02期
基金
英国惠康基金; 英国工程与自然科学研究理事会;
关键词
LOWER-LIMB MODEL; JOINT CONTACT; PROVIDES INSIGHT; MUSCULO-TENDON; MUSCLE; OPTIMIZATION; KINEMATICS; DYNAMICS; VALIDATION;
D O I
10.1115/1.4032412
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Segment-based musculoskeletal models allow the prediction of muscle, ligament, and joint forces without making assumptions regarding joint degrees-of-freedom (DOF). The dataset published for the "Grand Challenge Competition to Predict in vivo Knee Loads" provides directly measured tibiofemoral contact forces for activities of daily living (ADL). For the Sixth Grand Challenge Competition to Predict in vivo Knee Loads, blinded results for "smooth" and "bouncy" gait trials were predicted using a customized patient-specific musculoskeletal model. For an unblinded comparison, the following modifications were made to improve the predictions: further customizations, including modifications to the knee center of rotation; reductions to the maximum allowable muscle forces to represent known loss of strength in knee arthroplasty patients; and a kinematic constraint to the hip joint to address the sensitivity of the segment-based approach to motion tracking artifact. For validation, the improved model was applied to normal gait, squat, and sit-to-stand for three subjects. Comparisons of the predictions with measured contact forces showed that segment-based musculoskeletal models using patient-specific input data can estimate tibiofemoral contact forces with root mean square errors (RMSEs) of 0.48-0.65 times body weight (BW) for normal gait trials. Comparisons between measured and predicted tibiofemoral contact forces yielded an average coefficient of determination of 0.81 and RMSEs of 0.46-1.01 times BW for squatting and 0.70-0.99 times BW for sit-to-stand tasks. This is comparable to the best validations in the literature using alternative models.
引用
收藏
页数:9
相关论文
共 51 条
[1]   Evaluation of translation in the normal and dysplastic hip using three-dimensional magnetic resonance imaging and voxel-based registration [J].
Akiyama, K. ;
Sakai, T. ;
Koyanagi, J. ;
Yoshikawa, H. ;
Sugamoto, K. .
OSTEOARTHRITIS AND CARTILAGE, 2011, 19 (06) :700-710
[2]   Dynamic optimization of human walking [J].
Anderson, FC ;
Pandy, MG .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2001, 123 (05) :381-390
[3]  
[Anonymous], SBC201019353 ASME
[4]   How muscle fiber lengths and velocities affect muscle force generation as humans walk and run at different speeds [J].
Arnold, Edith M. ;
Hamner, Samuel R. ;
Seth, Ajay ;
Millard, Matthew ;
Delp, Scott L. .
JOURNAL OF EXPERIMENTAL BIOLOGY, 2013, 216 (11) :2150-2160
[5]   A Model of the Lower Limb for Analysis of Human Movement [J].
Arnold, Edith M. ;
Ward, Samuel R. ;
Lieber, Richard L. ;
Delp, Scott L. .
ANNALS OF BIOMEDICAL ENGINEERING, 2010, 38 (02) :269-279
[6]   HIP-JOINT LOADING DURING WALKING AND RUNNING, MEASURED IN 2 PATIENTS [J].
BERGMANN, G ;
GRAICHEN, F ;
ROHLMANN, A .
JOURNAL OF BIOMECHANICS, 1993, 26 (08) :969-990
[7]   A novel technique to measure active tendon forces: application to the subscapularis tendon [J].
Bull, AMJ ;
Reilly, P ;
Wallace, AL ;
Amis, AA ;
Emery, RJH .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2005, 13 (02) :145-150
[8]   Prediction of in vivo joint mechanics of an artificial knee implant using rigid multi-body dynamics with elastic contacts [J].
Chen, Zhenxian ;
Zhang, Xuan ;
Ardestani, Marzieh M. ;
Wang, Ling ;
Liu, Yaxiong ;
Lian, Qin ;
He, Jiankang ;
Li, Dichen ;
Jin, Zhongmin .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2014, 228 (06) :564-575
[9]   The development of a segment-based musculoskeletal model of the lower limb: introducing FREEBODY [J].
Cleather, Daniel J. ;
Bull, Anthony M. J. .
ROYAL SOCIETY OPEN SCIENCE, 2015, 2 (06)
[10]   An Optimization-Based Simultaneous Approach to the Determination of Muscular, Ligamentous, and Joint Contact Forces Provides Insight into Musculoligamentous Interaction [J].
Cleather, Daniel J. ;
Bull, Anthony M. J. .
ANNALS OF BIOMEDICAL ENGINEERING, 2011, 39 (07) :1925-1934