Experimental Evaluation and Finite Element Analysis of Stress Distribution in 3D-Printed Dental Implants to Validate the Optimal Thread Pitch

被引:0
|
作者
Irudhayam, Jackson S. [1 ]
Venkatesan, Hariram [1 ]
机构
[1] Hindustan Inst Technol & Sci, Dept Mech Engn, Chennai 603103, Tamil Nadu, India
来源
REVUE DES COMPOSITES ET DES MATERIAUX AVANCES-JOURNAL OF COMPOSITE AND ADVANCED MATERIALS | 2024年 / 34卷 / 02期
关键词
photoelasticity test FEA; design CFR PEEK; dental implant; stress distribution; BONE; DIAMETER; LENGTH;
D O I
10.18280/rcma.340215
中图分类号
TB33 [复合材料];
学科分类号
摘要
Objective: As an alternative method of prosthetic rehabilitation, the dental implant serves as one of the solutions that may be used to restore a missing tooth over a lengthy period of time. In order to achieve stress concentration in 3D printed 30% CFR PEEK dental implants, the finite element approach and the experimental photoelasticity test are applied. This is done in order to find the optimal thread pitch for a 3D printed 30% CFR PEEK implant and its impact on the bone implant interface. Materials and methods: Three-dimensional models were generated for the one-piece implant and bone structures. The models were created by introducing variations of 0.8mm, 1mm, and 1.2mm in the thread pitch while maintaining a fixed implant length of 13mm. SolidWorks software was employed for the creation of these models. Subsequently, the stress distribution of the models was simulated under axial load using ANSYS software. An experimental model was created utilizing 3D printing technology, and further experimental tests were conducted to assess the stress concentration in dental implants -bone interfaces. These evaluations were performed using the photoelasticity test method. Results: As a result of the findings, it seems that the implant, cortical, and cancellous bones all exhibit different levels of stress intensity. A thorough analysis of the stress intensity is used to establish the optimal configuration for the pitch of the components and the behavior of 3D printed implant in cancellous bone. Conclusions: After careful consideration, it has been shown that the current finite element model adequately forecasts the stress concentration pattern of dental implants. In light of the fact that the findings of the FEM test are more accurate than those of the photoelasticity test, it is recommended that computation techniques be used in medical practice since they have tremendous potential for new research. This research suggested that the optimum ranges for the length and pitch of the 3D printed 30% CFR PEEK implant are determined to be 13mm and 0.8mm, respectively and a low implant thread pitch results in a reduction in stress concentration at the implantcancellous bone interface.
引用
收藏
页码:257 / 267
页数:11
相关论文
共 50 条
  • [41] Investigating the impact of diameters and thread designs on the Biomechanics of short implants placed in D4 bone: a 3D finite element analysis
    Alqahtani, Ali Robaian
    Desai, Shrikar R.
    Patel, Jignesh R.
    Alqhtani, Nasser Raqe
    Alqahtani, Abdullah Saad
    Heboyan, Artak
    Fernandes, Gustavo V. O.
    Mustafa, Mohammed
    Karobari, Mohamed Isaqali
    BMC ORAL HEALTH, 2023, 23 (01)
  • [42] Effects of custom-made and thread dental implant systems on the stress distribution in alveolar bone: a 3-dimensional finite element analysis
    Zhang, Xiao
    Xie, Zhangong
    Feng, Wei
    Chen, Xianshuai
    Chen, Jianyu
    SENSORS, MEASUREMENT AND INTELLIGENT MATERIALS II, PTS 1 AND 2, 2014, 475-476 : 1487 - +
  • [43] Influence of a micro-thread at cervical position and a cylindrical intermediate zone on the mechanical behaviour of dental implants: A three-dimensional finite element analysis
    Garitaonaindia, Ugutz
    Alcaraz, Jose Luis
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2015, 229 (09) : 670 - 680
  • [44] Evaluation of postoperative dental implant primary stability using 3D finite element analysis
    Pammer, David
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2019, 22 (03) : 280 - 287
  • [45] Biomechanical Evaluation of Stress Distribution in Subcrestal Placed Platform-switched Short Dental Implants in D4 Bone: In Vitro Finite-element Model Study
    Sesha, Manchala R.
    Sunduram, Rajashekar
    Abdelmagyd, Hossam A. Eid
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2020, 12 : 134 - 139
  • [46] UNDERSTANDING THE BIOMECHANICAL RESPONSE OF PROGRESSIVE THREAD DENTAL IMPLANTS USING MULTI-SCALE FINITE ELEMENT ANALYSIS
    Chakraborty A.
    Sahare K.D.
    Majumder S.
    Chowdhury A.R.
    International Journal for Multiscale Computational Engineering, 2024, 22 (4 Special Issue) : 31 - 44
  • [47] Finite element analysis of stress distribution around a dental implant with different amounts of bone loss: An in vitro study
    Jafarian, Mohammad
    Mirhashemi, Fatemeh Sadat
    Emadi, Naghmeh
    DENTAL AND MEDICAL PROBLEMS, 2019, 56 (01) : 27 - 32
  • [48] Finite element analysis and clinical application of 3D-printed Ti alloy implant for the reconstruction of mandibular defects
    Xue, Runqi
    Lai, Qingguo
    Xing, Hongyu
    Zhong, Chiyang
    Zhao, Yixuan
    Zhu, Kaiwen
    Deng, Yanwei
    Liu, Chengbin
    BMC ORAL HEALTH, 2024, 24 (01)
  • [49] Effects of different inter-implant distances on the stress distribution around endosseous implants in posterior mandible: A 3D finite element analysis
    Simsek, B
    Erkmen, E
    Yilmaz, D
    Eser, A
    MEDICAL ENGINEERING & PHYSICS, 2006, 28 (03) : 199 - 213
  • [50] Thread shape affects the stress distribution of torque force on miniscrews: a finite element analysis
    Ye, Yu-shan
    Yi, Wei-min
    Zhuang, Pei-lin
    Liu, Mo
    Yu, Yan-song
    Lu, Ying-juan
    Yao, Qing-he
    Wang, Wei
    Chang, Shao-hai
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2020, 23 (13) : 1034 - 1040