Setting positive end-expiratory pressure: does the 'best compliance' concept really work?

被引:4
|
作者
Menga, Luca S. [1 ,2 ,3 ,4 ]
Subira, Carles [1 ,2 ,5 ,6 ,7 ]
Wong, Alfred [1 ,2 ]
Sousa, Mayson [1 ,2 ]
Brochard, Laurent J. [1 ,2 ,8 ]
机构
[1] St Michaels Hosp, Li Ka Shing Knowledge Inst, Keenan Res Ctr, Toronto, ON, Canada
[2] Univ Toronto, Interdept Div Crit Care Med, Toronto, ON, Canada
[3] Univ Cattolica Sacro Cuore, Fac Med & Chirurg, Anesthesiol & Intens Care Med, Rome, Italy
[4] Fdn Policlin Univ A Gemelli IRCCS, Anesthesia Emergency & Intens Care Med, Rome, Italy
[5] Inst Salud Carlos III, Ctr Invest Biomed Red Enfermedades Respiratorias, Madrid, Spain
[6] Althaia Xarxa Assistencial Univ Manresa, IRIS Res Inst, Crit Care Dept, Manresa, Spain
[7] Inst Recerca Biomed Catalunya Cent IRIS CC, Grup Recerca Malalt Crit GMC, Vic, Spain
[8] St Michaels Hosp, Unity Hlth Toronto, Keenan Res Ctr, 209 Victoria St,Room408, Toronto, ON M5B1T8, Canada
关键词
acute respiratory distress syndrome; compliance; overdistention; positive end-expiratory pressure; recruitment; ACUTE LUNG INJURY; RESPIRATORY-DISTRESS-SYNDROME; MECHANICAL VENTILATION; DRIVING PRESSURE; TRANSPULMONARY PRESSURE; RECRUITMENT MANEUVERS; ESOPHAGEAL PRESSURE; ALVEOLAR COLLAPSE; TIDAL VOLUMES; PEEP;
D O I
10.1097/MCC.0000000000001121
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose of reviewDetermining the optimal positive end-expiratory pressure (PEEP) setting remains a central yet debated issue in the management of acute respiratory distress syndrome (ARDS).The 'best compliance' strategy set the PEEP to coincide with the peak respiratory system compliance (or 2 cmH2O higher) during a decremental PEEP trial, but evidence is conflicting.Purpose of reviewDetermining the optimal positive end-expiratory pressure (PEEP) setting remains a central yet debated issue in the management of acute respiratory distress syndrome (ARDS).The 'best compliance' strategy set the PEEP to coincide with the peak respiratory system compliance (or 2 cmH2O higher) during a decremental PEEP trial, but evidence is conflicting.Recent findingsThe physiological rationale that best compliance is always representative of functional residual capacity and recruitment has raised serious concerns about its efficacy and safety, due to its association with increased 28-day all-cause mortality in a randomized clinical trial in ARDS patients.Moreover, compliance measurement was shown to underestimate the effects of overdistension, and neglect intra-tidal recruitment, airway closure, and the interaction between lung and chest wall mechanics, especially in obese patients. In response to these concerns, alternative approaches such as recruitment-to-inflation ratio, the nitrogen wash-in/wash-out technique, and electrical impedance tomography (EIT) are gaining attention to assess recruitment and overdistention more reliably and precisely.Recent findingsThe physiological rationale that best compliance is always representative of functional residual capacity and recruitment has raised serious concerns about its efficacy and safety, due to its association with increased 28-day all-cause mortality in a randomized clinical trial in ARDS patients.Moreover, compliance measurement was shown to underestimate the effects of overdistension, and neglect intra-tidal recruitment, airway closure, and the interaction between lung and chest wall mechanics, especially in obese patients. In response to these concerns, alternative approaches such as recruitment-to-inflation ratio, the nitrogen wash-in/wash-out technique, and electrical impedance tomography (EIT) are gaining attention to assess recruitment and overdistention more reliably and precisely.SummaryThe traditional 'best compliance' strategy for determining optimal PEEP settings in ARDS carries risks and overlooks some key physiological aspects. The advent of new technologies and methods presents more reliable strategies to assess recruitment and overdistention, facilitating personalized approaches to PEEP optimization.
引用
收藏
页码:20 / 27
页数:8
相关论文
共 50 条
  • [21] Positive end-expiratory pressure or no positive end-expiratory pressure: is that the question to be asked?
    Villar, J
    CRITICAL CARE, 2003, 7 (02): : 192 - 192
  • [22] Positive end-expiratory pressure or no positive end-expiratory pressure: is that the question to be asked?
    Jesús Villar
    Critical Care, 7
  • [23] Individualized positive end-expiratory pressure application in patients with acute respiratory distress syndrome
    Pintado, M. C.
    de Pablo, R.
    MEDICINA INTENSIVA, 2014, 38 (08) : 498 - 501
  • [24] Ultrasonic monitoring in the assessment of pulmonary recruitment and the best positive end-expiratory pressure
    Tang, Ke-Qiang
    Yang, Shao-Ling
    Zhang, Bin
    Liu, Hong-Xiang
    Ye, Dong-Ying
    Zhang, Hong-Ze
    Ma, Shuang
    MEDICINE, 2017, 96 (39)
  • [25] High Positive End-Expiratory Pressure Renders Spontaneous Effort Noninjurious
    Morais, Caio C. A.
    Koyama, Yukiko
    Yoshida, Takeshi
    Plens, Glauco M.
    Gomes, Susimeire
    Lima, Cristhiano A. S.
    Ramos, Ozires P. S.
    Pereira, Sergio M.
    Kawaguchi, Naomasa
    Yamamoto, Hirofumi
    Uchiyama, Akinori
    Borges, Joao B.
    Melo, Marcos F. Vidal
    Tucci, Mauro R.
    Amato, Marcelo B. P.
    Kavanagh, Brian P.
    Costa, Eduardo L. V.
    Fujino, Yuji
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2018, 197 (10) : 1285 - 1296
  • [26] Positive end-expiratory pressure titrated according to respiratory system mechanics or to ARDSNetwork table did not guarantee positive end-expiratory transpulmonary pressure in acute respiratory distress syndrome
    Krebs, Joerg
    Pelosi, Paolo
    Rocco, Patricia R. M.
    Hagmann, Michael
    Luecke, Thomas
    JOURNAL OF CRITICAL CARE, 2018, 48 : 433 - 442
  • [27] Personalized Positive End-Expiratory Pressure in Acute Respiratory Distress Syndrome: Comparison Between Optimal Distribution of Regional Ventilation and Positive Transpulmonary Pressure
    Scaramuzzo, Gaetano
    Spadaro, Savino
    Dalla Corte, Francesca
    Waldmann, Andreas D.
    Boehm, Stephan H.
    Ragazzi, Riccardo
    Marangoni, Elisabetta
    Grasselli, Giacomo
    Pesenti, Antonio
    Volta, Carlo Alberto
    Mauri, Tommaso
    CRITICAL CARE MEDICINE, 2020, 48 (08) : 1148 - 1156
  • [28] Positive End-expiratory Pressure and Mechanical Power
    Collino, Francesca
    Rapetti, Francesca
    Vasques, Francesco
    Maiolo, Giorgia
    Tonetti, Tommaso
    Romitti, Federica
    Niewenhuys, Julia
    Behnemann, Tim
    Camporota, Luigi
    Hahn, Guenter
    Reupke, Verena
    Holke, Karin
    Herrmann, Peter
    Duscio, Eleonora
    Cipulli, Francesco
    Moerer, Onnen
    Marini, John J.
    Quintel, Michael
    Gattinoni, Luciano
    ANESTHESIOLOGY, 2019, 130 (01) : 119 - 130
  • [29] Setting positive end-expiratory pressure during jet ventilation to replicate the mean airway pressure of oscillatory ventilation
    Bass, Andora L.
    Gentile, Michael A.
    Heinz, John P.
    Craig, Damian M.
    Hamel, Donna S.
    Cheifetz, Ira M.
    RESPIRATORY CARE, 2007, 52 (01) : 50 - 55
  • [30] Intracranial pressure responsiveness to positive end-expiratory pressure is influenced by chest wall elastance: a physiological study in patients with aneurysmal subarachnoid hemorrhage
    Chen, Han
    Chen, Kai
    Xu, Jing-Qing
    Zhang, Ying-Rui
    Yu, Rong-Guo
    Zhou, Jian-Xin
    BMC NEUROLOGY, 2018, 18