共 50 条
Setting positive end-expiratory pressure: does the 'best compliance' concept really work?
被引:4
|作者:
Menga, Luca S.
[1
,2
,3
,4
]
Subira, Carles
[1
,2
,5
,6
,7
]
Wong, Alfred
[1
,2
]
Sousa, Mayson
[1
,2
]
Brochard, Laurent J.
[1
,2
,8
]
机构:
[1] St Michaels Hosp, Li Ka Shing Knowledge Inst, Keenan Res Ctr, Toronto, ON, Canada
[2] Univ Toronto, Interdept Div Crit Care Med, Toronto, ON, Canada
[3] Univ Cattolica Sacro Cuore, Fac Med & Chirurg, Anesthesiol & Intens Care Med, Rome, Italy
[4] Fdn Policlin Univ A Gemelli IRCCS, Anesthesia Emergency & Intens Care Med, Rome, Italy
[5] Inst Salud Carlos III, Ctr Invest Biomed Red Enfermedades Respiratorias, Madrid, Spain
[6] Althaia Xarxa Assistencial Univ Manresa, IRIS Res Inst, Crit Care Dept, Manresa, Spain
[7] Inst Recerca Biomed Catalunya Cent IRIS CC, Grup Recerca Malalt Crit GMC, Vic, Spain
[8] St Michaels Hosp, Unity Hlth Toronto, Keenan Res Ctr, 209 Victoria St,Room408, Toronto, ON M5B1T8, Canada
关键词:
acute respiratory distress syndrome;
compliance;
overdistention;
positive end-expiratory pressure;
recruitment;
ACUTE LUNG INJURY;
RESPIRATORY-DISTRESS-SYNDROME;
MECHANICAL VENTILATION;
DRIVING PRESSURE;
TRANSPULMONARY PRESSURE;
RECRUITMENT MANEUVERS;
ESOPHAGEAL PRESSURE;
ALVEOLAR COLLAPSE;
TIDAL VOLUMES;
PEEP;
D O I:
10.1097/MCC.0000000000001121
中图分类号:
R4 [临床医学];
学科分类号:
1002 ;
100602 ;
摘要:
Purpose of reviewDetermining the optimal positive end-expiratory pressure (PEEP) setting remains a central yet debated issue in the management of acute respiratory distress syndrome (ARDS).The 'best compliance' strategy set the PEEP to coincide with the peak respiratory system compliance (or 2 cmH2O higher) during a decremental PEEP trial, but evidence is conflicting.Purpose of reviewDetermining the optimal positive end-expiratory pressure (PEEP) setting remains a central yet debated issue in the management of acute respiratory distress syndrome (ARDS).The 'best compliance' strategy set the PEEP to coincide with the peak respiratory system compliance (or 2 cmH2O higher) during a decremental PEEP trial, but evidence is conflicting.Recent findingsThe physiological rationale that best compliance is always representative of functional residual capacity and recruitment has raised serious concerns about its efficacy and safety, due to its association with increased 28-day all-cause mortality in a randomized clinical trial in ARDS patients.Moreover, compliance measurement was shown to underestimate the effects of overdistension, and neglect intra-tidal recruitment, airway closure, and the interaction between lung and chest wall mechanics, especially in obese patients. In response to these concerns, alternative approaches such as recruitment-to-inflation ratio, the nitrogen wash-in/wash-out technique, and electrical impedance tomography (EIT) are gaining attention to assess recruitment and overdistention more reliably and precisely.Recent findingsThe physiological rationale that best compliance is always representative of functional residual capacity and recruitment has raised serious concerns about its efficacy and safety, due to its association with increased 28-day all-cause mortality in a randomized clinical trial in ARDS patients.Moreover, compliance measurement was shown to underestimate the effects of overdistension, and neglect intra-tidal recruitment, airway closure, and the interaction between lung and chest wall mechanics, especially in obese patients. In response to these concerns, alternative approaches such as recruitment-to-inflation ratio, the nitrogen wash-in/wash-out technique, and electrical impedance tomography (EIT) are gaining attention to assess recruitment and overdistention more reliably and precisely.SummaryThe traditional 'best compliance' strategy for determining optimal PEEP settings in ARDS carries risks and overlooks some key physiological aspects. The advent of new technologies and methods presents more reliable strategies to assess recruitment and overdistention, facilitating personalized approaches to PEEP optimization.
引用
收藏
页码:20 / 27
页数:8
相关论文