Biomechanical Performance of Hip Labral Repair Techniques

被引:13
作者
Hapa, Onur [1 ]
Barber, F. Alan [2 ]
Basci, Onur [1 ]
Horoz, Levent [1 ]
Ertem, Fatih [3 ]
Karakasli, Ahmet [1 ]
Havitcioglu, Hasan [1 ]
机构
[1] Dokuz Eylul Univ, Dept Orthoped Surg, TR-35340 Izmir, Turkey
[2] Plano Orthoped & Sports Med Ctr, Plano, TX USA
[3] Dokuz Eylul Univ, Dept Biomech, TR-35340 Izmir, Turkey
关键词
HUMAN ACETABULAR LABRUM; FEMOROACETABULAR IMPINGEMENT; TENSILE PROPERTIES; CLINICAL-OUTCOMES; CAPSULAR REPAIR; OVINE MODEL; FOLLOW-UP; STRENGTH; SUTURE; RECONSTRUCTION;
D O I
10.1016/j.arthro.2015.12.044
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To determine the strength of various suture techniques and the impact of suture passer size on cyclically loaded hip labra. Methods: We assigned 63 bovine hip labra to 9 simple knotless suture technique groups using OrthoCord suture: (1) penetrating grasper (2.6 mm)-placed horizontal mattress, (2) penetrating grasper-placed vertical mattress, (3) SutureLasso (1.8 mm)-placed vertical mattress, (4) penetrating grasper-placed oblique repair, (5) penetrating grasper-placed vertical mattress plus radiofrequency, (6) SutureLasso-placed horizontal mattress, (7) SutureLasso-placed oblique mattress, (8) SutureLasso-placed horizontal mattress plus radiofrequency, and (9) SutureLasso-placed oblique mattress plus radiofrequency. After 20 cycles of uniaxial tensile loading (5 to 80 N), destructive testing was performed. Results: Penetrating grasper-placed horizontal mattress sutures showed lower ultimate failure loads than vertical and oblique mattress sutures (P < .05). Penetrating grasper-placed vertical mattress sutures had higher peak-to-peak displacement than SutureLasso-placed vertical mattress sutures (P = .04). SutureLasso-placed oblique mattress sutures had a higher ultimate load (P < .01) and stiffness (P = .04) than SutureLasso-placed horizontal mattress sutures. SutureLasso-placed horizontal mattress sutures had lower cyclic elongation than penetrating grasper-placed horizontal mattress sutures (P = .01) and lower ultimate load (P < .01) and stiffness than SutureLasso-placed vertical mattress sutures (P < .01). Horizontal mattress sutures with radiofrequency had a higher ultimate load (P = .02), stiffness, and cyclic elongation (P < .01) than without radiofrequency. Conclusions: A horizontal mattress hip labrum stitch shows a lower ultimate failure load than vertical or oblique mattress stitches. Smaller-diameter suture-passing devices show less cyclic displacement and elongation than larger-diameter devices. Radiofrequency labral treatment does not alter vertical stitch strength but does alter horizontal mattress stitch strength. Clinical Relevance: Vertical and oblique stitches are stronger than horizontal stitches. A 1.8-mm passing device shows a better cyclic loading performance than a 2.6-mm device.
引用
收藏
页码:1010 / 1016
页数:7
相关论文
共 33 条
  • [1] Biomechanical Evaluation of Capsulotomy, Capsulectomy, and Capsular Repair on Hip Rotation
    Abrams, Geoffrey D.
    Hart, Michael A.
    Takami, Kaosu
    Bayne, Christopher O.
    Kelly, Bryan T.
    Orias, Alejandro A. Espinoza
    Nho, Shane J.
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2015, 31 (08) : 1511 - 1517
  • [2] Cyclic Load and Failure Behavior of Arthroscopic Knots and High Strength Sutures
    Barber, F. Alan
    Herbert, Morley A.
    Beavis, R. Cole
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2009, 25 (02) : 192 - 199
  • [3] Barber FA, 2006, ARTHROSCOPY, V22, p1063e1
  • [4] Clinical and Functional Outcome After Acetabular Labral Repair in Patients Aged Older Than 50 Years
    Ben Tov, Tomer
    Amar, Eyal
    Shapira, Amir
    Steinberg, Ely
    Atoun, Ehud
    Rath, Ehud
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2014, 30 (03) : 305 - 310
  • [5] Primary Repair of the Acetabular Labrum: Outcomes With 2 Years' Follow-Up
    Byrd, J. W. Thomas
    Jones, Kay S.
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2014, 30 (05) : 588 - 592
  • [6] Chokshi BV, 2006, BULL HOSP JT DIS, V63, P123
  • [7] Influence of Capsular Repair Versus Unrepaired Capsulotomy on 2-Year Clinical Outcomes After Arthroscopic Hip Preservation Surgery
    Domb, Benjamin G.
    Stake, Christine E.
    Finley, Zachary J.
    Chen, Tian
    Giordano, Brian D.
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2015, 31 (04) : 643 - 650
  • [8] Arthroscopic laser-assisted capsular shift in the treatment of patients with multidirectional shoulder instability
    Favorito, PJ
    Langendorfer, MA
    Colosimo, AJ
    Heidt, RS
    Carlonas, RL
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2002, 30 (03) : 322 - 328
  • [9] The material properties of the bovine acetabular labrum
    Ferguson, SJ
    Bryant, JT
    Ito, K
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2001, 19 (05) : 887 - 896
  • [10] Tensile Properties of the Human Acetabular Labrum and Hip Labral Reconstruction Grafts
    Ferro, Fernando P.
    Philippon, Marc J.
    Rasmussen, Matthew T.
    Smith, Sean D.
    LaPrade, Robert F.
    Wijdicks, Coen A.
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2015, 43 (05) : 1222 - 1227