ISQ for Assessing Implant Stability and Monitoring Healing: A Prospective Observational Comparison between Two Devices

被引:0
作者
Bavetta, Giueseppe [1 ]
Paderni, Carlo [1 ]
Bavetta, Giorgio [1 ]
Randazzo, Valentina [1 ]
Cavataio, Alessio [1 ]
Seidita, Francesco [1 ]
Khater, Ahmad G. A. [1 ,2 ]
Gehrke, Sergio Alexandre [3 ]
Tari, Sergio Rexhep [4 ]
Scarano, Antonio [4 ]
机构
[1] Egyptian Russian Univ ERU, Fac Oral & Dent Med, Badr City 11829, Egypt
[2] Egyptian Minist Hlth & Populat, Hlth Affairs Directorate, Banisuif 62511, Egypt
[3] Bioface PgO UCAM, Dept Res, Montevideo 11100, Uruguay
[4] Univ G dAnnunzio, Dept Innovat Technol Med & Dent, I-66100 Chieti, Italy
来源
PROSTHESIS | 2024年 / 6卷 / 02期
关键词
alveolar bone remodeling; dental implant; immediate loading; implantology; observational study; osseointegration; placement and loading protocol; prosthodontics; RESONANCE FREQUENCY-ANALYSIS; TITANIUM IMPLANTS;
D O I
10.3390/prosthesis6020027
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Background: With the growing use of dental implants, there is an urgent need to determine a prosthetic placement protocol by assessing implant stability and monitoring healing. Implant Stability Quotient (ISQ) values are produced using dental non-invasive devices through resonance frequency analysis, considered as indicators for measuring primary stability (i.e., at implant placement), monitoring biological stability (osseointegration), and prosthetic loading. A systematic and detailed comparison of ISQ measurement devices, for a given patient population, is lacking in the literature. This aspect is the subject of the present work, with the devices being two that are widely used in clinical practice (Osstell (R) and Osseo (R) 100). The aim of this study was to evaluate the reliability of ISQ measurement using two standard devices most commonly used in clinical practice and to highlight any differences when comparing measurements at undefined time intervals. Methods: We enrolled 50 patients (16 males and 34 females) with a mean age of 55.4 years, who indicated dental implant placement and met the inclusion criteria. The sample was divided into two equal groups based on bone density: A (D1-D2 bone density) and B (D3-D4 bone density); each had 25 patients with 40 implants. ISQ was measured using two devices: Osstell (R) and Osseo 100 (R), at different time points (A: three and B: four follow-ups). Results: All enrolled patients completed the study without adverse events; all implants placed were successful, with no implant failure. In each of the study groups, ISQ values increased gradually with increasing follow-up time, and there was no significant difference between Osstell and Osseo 100 values at follow-up times except for the T1 follow-up in group A. Temporal comparisons for the two devices revealed significant differences in T0 vs. T2 in group A, whereas significant differences existed in T0 vs. T1, T2, and T3 in group B. Our findings indicated that the overall effect significantly depended on bone density rather than on the device used to measure ISQ. Conclusion: Regardless of the devices used, the ISQ measurement effectively monitors healing after implant insertion and allows prosthetic load to be modulated according to the ISQ value, especially when prosthetizing implants placed in fine trabecular bone (D4 or regenerated bone).
引用
收藏
页码:357 / 371
页数:15
相关论文
共 50 条
  • [31] Evaluation of dental implant stability in bone phantoms: Comparison between a quantitative ultrasound technique and resonance frequency analysis
    Vayron, Romain
    Vu-Hieu Nguyen
    Lecuelle, Benoit
    Haiat, Guillaume
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2018, 20 (04) : 470 - 478
  • [32] Relationship between the CT Value and Cortical Bone Thickness at Implant Recipient Sites and Primary Implant Stability with Comparison of Different Implant Types
    Howashi, Miori
    Tsukiyama, Yoshihiro
    Ayukawa, Yasunori
    Isoda-Akizuki, Kei
    Kihara, Masafumi
    Imai, Yu
    Sogo, Motofumi
    Koyano, Kiyoshi
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2016, 18 (01) : 107 - 116
  • [33] Comparison of accuracy between digital and conventional implant impressions: two and three dimensional evaluations
    Bi, Chuang
    Wang, Xingyu
    Tian, Fangfang
    Qu, Zhe
    Zhao, Jiaming
    JOURNAL OF ADVANCED PROSTHODONTICS, 2022, 14 (04) : 236 - 249
  • [34] Comparison of Primary Stability of Two Different Implants Designs-A Prospective Clinical Study
    Sravanthi, A. Veena
    Manne, Prakash
    Surapaneni, Haragopal
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2023, 17 (01) : ZC16 - ZC19
  • [35] Assessment of the alveolar bone loss in fresh socket implant procedures with immediate implant loading via temporary preformed anatomical healing caps: Comparison of two different lengths of the implant collar
    Crespi, Roberto
    Toti, Paolo
    Covani, Ugo
    Cosola, Saverio
    Crespi, Giovanni
    Menchini-Fabris, Giovanni-Battista
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2023, 124 (06)
  • [36] Comparison of Audiologic Results and Patient Satisfaction for Two Osseointegrated Bone Conduction Devices: Results of a Prospective Study
    Busch, Susan
    Giere, Thomas
    Lenarz, Thomas
    Maier, Hannes
    OTOLOGY & NEUROTOLOGY, 2015, 36 (05) : 842 - 848
  • [37] Monitoring crestal bone level of single- and two-stage implant placement modes up to final prosthetic delivery: an observational study
    Artzi, Zvi
    Shlafstein, Rachel
    QUINTESSENCE INTERNATIONAL, 2021, 52 (03): : 236 - 246
  • [38] Evaluating cortico-cancellous ratio using virtual implant planning and its relation with immediate and long-term stability of a dental implant- A CBCT-assisted prospective observational clinical study
    Talluri, S.
    Vaddamanu, S. K.
    Apparaju, V.
    Vyas, R.
    Ahuja, S.
    Kanji, M. A.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2019, 22 (07) : 982 - 987
  • [39] Clinical and Radiographic Comparison between Platform-Shifted and Nonplatform-Shifted Implant: A One-Year Prospective Study
    Glibert, Maarten
    Vervaeke, Stijn
    De Bruyn, Hugo
    Oestman, Paer-Olov
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2016, 18 (01) : 129 - 137
  • [40] Two Different Implant Designs and Impact of Related Drilling Protocols on Primary Stability in Different Bone Densities: An In Vitro Comparison Study
    Sennerby, Lars
    Pagliani, Luca
    Petersson, Anders
    Verrocchi, Damiano
    Volpe, Stefano
    Andersson, Peter
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (03) : 564 - 568