ISQ for Assessing Implant Stability and Monitoring Healing: A Prospective Observational Comparison between Two Devices

被引:0
|
作者
Bavetta, Giueseppe [1 ]
Paderni, Carlo [1 ]
Bavetta, Giorgio [1 ]
Randazzo, Valentina [1 ]
Cavataio, Alessio [1 ]
Seidita, Francesco [1 ]
Khater, Ahmad G. A. [1 ,2 ]
Gehrke, Sergio Alexandre [3 ]
Tari, Sergio Rexhep [4 ]
Scarano, Antonio [4 ]
机构
[1] Egyptian Russian Univ ERU, Fac Oral & Dent Med, Badr City 11829, Egypt
[2] Egyptian Minist Hlth & Populat, Hlth Affairs Directorate, Banisuif 62511, Egypt
[3] Bioface PgO UCAM, Dept Res, Montevideo 11100, Uruguay
[4] Univ G dAnnunzio, Dept Innovat Technol Med & Dent, I-66100 Chieti, Italy
来源
PROSTHESIS | 2024年 / 6卷 / 02期
关键词
alveolar bone remodeling; dental implant; immediate loading; implantology; observational study; osseointegration; placement and loading protocol; prosthodontics; RESONANCE FREQUENCY-ANALYSIS; TITANIUM IMPLANTS;
D O I
10.3390/prosthesis6020027
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Background: With the growing use of dental implants, there is an urgent need to determine a prosthetic placement protocol by assessing implant stability and monitoring healing. Implant Stability Quotient (ISQ) values are produced using dental non-invasive devices through resonance frequency analysis, considered as indicators for measuring primary stability (i.e., at implant placement), monitoring biological stability (osseointegration), and prosthetic loading. A systematic and detailed comparison of ISQ measurement devices, for a given patient population, is lacking in the literature. This aspect is the subject of the present work, with the devices being two that are widely used in clinical practice (Osstell (R) and Osseo (R) 100). The aim of this study was to evaluate the reliability of ISQ measurement using two standard devices most commonly used in clinical practice and to highlight any differences when comparing measurements at undefined time intervals. Methods: We enrolled 50 patients (16 males and 34 females) with a mean age of 55.4 years, who indicated dental implant placement and met the inclusion criteria. The sample was divided into two equal groups based on bone density: A (D1-D2 bone density) and B (D3-D4 bone density); each had 25 patients with 40 implants. ISQ was measured using two devices: Osstell (R) and Osseo 100 (R), at different time points (A: three and B: four follow-ups). Results: All enrolled patients completed the study without adverse events; all implants placed were successful, with no implant failure. In each of the study groups, ISQ values increased gradually with increasing follow-up time, and there was no significant difference between Osstell and Osseo 100 values at follow-up times except for the T1 follow-up in group A. Temporal comparisons for the two devices revealed significant differences in T0 vs. T2 in group A, whereas significant differences existed in T0 vs. T1, T2, and T3 in group B. Our findings indicated that the overall effect significantly depended on bone density rather than on the device used to measure ISQ. Conclusion: Regardless of the devices used, the ISQ measurement effectively monitors healing after implant insertion and allows prosthetic load to be modulated according to the ISQ value, especially when prosthetizing implants placed in fine trabecular bone (D4 or regenerated bone).
引用
收藏
页码:357 / 371
页数:15
相关论文
共 50 条
  • [21] Comparison of Measurements of Implant Stability by Two Different Radio Frequency Analysis Systems: An In Vitro Study
    Koyuncuoglu, Cenker Zeki
    Demir, Becen
    JOURNAL OF ADVANCED ORAL RESEARCH, 2020, 11 (02) : 202 - 207
  • [22] Evaluation of Correlation between Vitamin D Levels and Implant Stability in Indian Population: A Prospective Study in Bangalore
    Bhandage, Supriya
    Kumar, A. Harish
    Nayana, R.
    JOURNAL OF MAXILLOFACIAL & ORAL SURGERY, 2022, 21 (03) : 808 - 814
  • [23] Evaluation of Correlation between Vitamin D Levels and Implant Stability in Indian Population: A Prospective Study in Bangalore
    Supriya Bhandage
    A. Harish Kumar
    R. Nayana
    Journal of Maxillofacial and Oral Surgery, 2022, 21 : 808 - 814
  • [24] Observational study on primary and secondary stability of two current bone level implant designs
    Steiner, Constanze
    Karl, Matthias
    Steiner, Dirk
    Meyer, Birgit
    QUINTESSENCE INTERNATIONAL, 2021, 52 (03): : 230 - 235
  • [25] Comparison of implant stability measurements between a resonance frequency analysis device and a modified damping capacity analysis device: an in vitro study
    Lee, Jungwon
    Pyo, Se-Wook
    Cho, Hyun-Jae
    An, Jung-Sub
    Lee, Jae-Hyun
    Koo, Ki-Tae
    Lee, Yong-Moo
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2020, 50 (01) : 56 - 66
  • [26] Comparison of the stability of immediate dental implant placement in fresh molar extraction sockets in the maxila and mandible: a controled , prospective, non-randomized clinical trial
    Witoonkitvanich, P.
    Amornsettachai, P.
    Panyayong, W.
    Rokaya, D.
    Vongsirichat, N.
    Suphangul, S.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2025, 54 (04) : 365 - 373
  • [27] Comparison of implant stability measurement devices for bone-anchored hearing aid systems
    Westover, Lindsey
    Faulkner, Gary
    Hodgetts, William
    Raboud, Don
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (01) : 178 - 184
  • [28] Resonance frequency analysis with two different devices after conventional implant placement with ridge preservation: A prospective pilot cohort study
    Brouwers, Joost E. I. G.
    Buis, Sharon
    de Groot, Philip G.
    de Laat, Bas
    Remijn, Jasper A.
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2021, 23 (05) : 789 - 799
  • [29] Comparison of implant primary stability between maxillary edentulous ridges receiving intramembranous origin block grafts
    Monje, Alberto
    Monje, Florencio
    Suarez, Fernando
    Gonzalez-Garcia, Raul
    Villanueva-Alcojol, Laura
    Garcia-Nogales, Agustin
    Galindo-Moreno, Pablo
    Wang, Hom-Lay
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2013, 18 (03): : E449 - E454
  • [30] Correlation of two different devices for the evaluation of primary implant stability depending on dental implant length and bone density: An in vitro study
    Lee, Jungwon
    Lim, Young-Jun
    Ahn, Jin-Soo
    Kim, Bongju
    Baek, Yeon-Wha
    Lim, Bum-Soon
    PLOS ONE, 2024, 19 (05):