Flow patterns and heat transfer of an idealized square city in non-uniform heat flux and different background wind conditions

被引:3
|
作者
Teng, Xiaoliang [1 ,2 ]
Zhang, Yan [1 ,2 ]
Fan, Yifan [1 ,2 ]
Ge, Jian [1 ,2 ]
机构
[1] Zhejiang Univ, Coll Civil Engn & Architecture, Hangzhou, Peoples R China
[2] Zhejiang Univ, Int Res Ctr Green Bldg & Low Carbon City, Int Campus, Haining, Peoples R China
关键词
Urban heat dome flow; Non-uniform heat flux; City ventilation; Heat removal; STABLY STRATIFIED ENVIRONMENT; SURFACE-ENERGY BALANCE; URBAN; ISLAND; CONVECTION; CHINA; SCALE; CALM;
D O I
10.1016/j.buildenv.2024.111779
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The city scale buoyancy-driven flow is crucial for the wind and thermal environment in urban areas, exerting a significant impact on the city ventilation, pollutants dispersion and heat removal. The intra-urban variations of hot spots and heat flux are drawing more attention on beating the urban heat. This study aims at analyzing the influences of non-uniform heat flux and background wind on the city-scale heat removal ability and underlying mechanisms. The large eddy simulation model was used and verified with water tank experiments. Results show that positive heat flux and negative heat flux in the rural areas will enhance and depress the strength of the urban heat dome flow respectively compared to the adiabatic condition. The high-speed regions are wider and stronger when the rural area has positive heat flux condition. Under positive rural heat flux condition, the time-average mixed layer height in urban areas across the city center plane is nearly twice that under negative rural heat flux condition. Besides, the city-scale heat transfer coefficients in positive rural heat flux condition are higher than those under negative rural heat flux and adiabatic conditions. For cases of non-uniform heat flux in urban areas, the differences of time-average mixed layer height and heat transfer coefficients are not obvious. The heat transfer coefficients decrease initially and then increase with increasing background wind speed indicating the non-linear interaction between approaching wind and urban heat dome flow. Moreover, the growth rate of the heat transfer coefficient decreases when the non-dimensional wind speed exceeds 1.19.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Heat transfer characteristics of horizontal flow boiling with uniform and non-uniform circumferential heat flux
    Araujo, A. K. A.
    Passos, J. C.
    Ferreira, T. P. A.
    van der Geld, C. W. M.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2024, 228
  • [2] The effect of circumferentially non-uniform heat flux on flow boiling heat transfer in a horizontal tube
    Dirker, Jaco
    Scheepers, Hannalie
    Meyer, Josua P.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2022, 185
  • [3] Impact of non-uniform heat flux conditions on convective heat transfer and energy efficiency in a corrugated tube
    Rabby, Md Insiat Islam
    Uddin, Md Wasi
    Hossain, Farzad
    ul-Iman, Safwan
    HELIYON, 2024, 10 (11)
  • [4] Flow and heat transfer characteristics of micro-channel cooling chip at non-uniform heat flux
    Shen L.
    Ji J.
    Luo F.
    Chen J.
    Xie J.
    Huang T.
    Zhongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Central South University (Science and Technology), 2021, 52 (06): : 1809 - 1816
  • [5] Modeling and simulation on the mass flow distribution in microchannel heat sinks with non-uniform heat flux conditions
    Cho, Eun Seok
    Choi, Jong Won
    Yoon, Jae Sung
    Kim, Min Soo
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2010, 53 (7-8) : 1341 - 1348
  • [6] NUMERICAL STUDY OF MICROCHANNEL HEAT SINKS WITH NON-UNIFORM HEAT FLUX CONDITIONS
    Ling, Ling
    Fan, Yanfeng
    Hassan, Ibrahim
    PROCEEDINGS OF THE ASME 9TH INTERNATIONAL CONFERENCE ON NANOCHANNELS, MICROCHANNELS AND MINICHANNELS 2011, VOL 2, 2012, : 87 - 93
  • [7] Heat transfer and thermal stresses in a circular tube with a non-uniform heat flux
    Marugan-Cruz, C.
    Flores, O.
    Santana, D.
    Garcia-Villalba, M.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 96 : 256 - 266
  • [8] Critical heat flux of subcooled flow boiling in tube with and without internal twisted tape under uniform and non-uniform heat flux conditions
    Nariai, H
    Inasaka, F
    CONVECTIVE FLOW BOILING, 1996, : 207 - 212
  • [9] Flow and heat transfer characteristics of non-uniform heat-pipe heat exchanger
    Qian M.
    Hu H.
    Xiang Z.
    Ma C.
    Hu X.
    Fangzhi Xuebao/Journal of Textile Research, 2021, 42 (12): : 151 - 158
  • [10] Experimental and numerical investigation of heat transfer for two-layered microchannel heat sink with non-uniform heat flux conditions
    Xu, Shanglong
    Yang, Lili
    Li, Yue
    Wu, Yihao
    Hu, Xinglong
    HEAT AND MASS TRANSFER, 2016, 52 (09) : 1755 - 1763