Two-Year Clinical Outcomes of the PAUL Glaucoma Implant in White Patients With Refractory Glaucoma

被引:2
|
作者
Weber, Constance [1 ]
Hundertmark, Sarah [1 ]
Stasik, Isabel [1 ]
Holz, Frank G. [1 ]
Mercieca, Karl [1 ]
机构
[1] Univ Bonn, Dept Ophthalmol, Bonn, Germany
关键词
Glaucoma surgery; PAUL glaucoma implant; glaucoma drainage device; BAERVELDT;
D O I
10.1097/IJG.0000000000002457
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Pr & eacute;cis:This prospectively collected case series of 56 eyes having PAUL glaucoma implant (PGI) surgery is the first to demonstrate its medium-term safety and effectiveness in what is essentially an exclusively Caucasian population.Background:To report 2-year outcomes from a single-center cohort undergoing PGI surgery.Methods:Prospectively collected data on patients undergoing PGI surgery at the University Eye Hospital Bonn, Germany, from April 2021 to September 2021.Results:Of 53 patients, 56 eyes were included. Complete and qualified success rates (95% CI) were 52% (37-66) and 89% (80-96) for criterion A ( intraocular pressure [IOP]<= 21 mm Hg), 48% (36-61) and 79% (67-88) for criterion B (IOP <= 18 mm Hg), 45% (32-57) and 64% (52-77%) for criterion C (IOP <= 15 mm Hg) and 27% (16-40) and 38% (25-50) for criterion D (IOP <= 12 mm Hg), respectively. Mean IOP decreased from 25.43 mm Hg (7-48 mm Hg) to 11.25 mm Hg (3-24 mm Hg) (reduction of 50%) after 24 months with a reduction of IOP-lowering agents from 3.50 (1-5) to 0.46 (0-3). One eye needed an injection of viscoelastic due to significant hypotony with AC shallowing; 3 eyes received a Descemet membrane endothelial keratoplasty because of persistent corneal decompensation; 9 eyes developed tube exposure which required conjunctival revision with additional pericardial patch graft, with 5 of these eyes eventually needing tube explantation. An intraluminal prolene stent was removed in 24 eyes (42.9%) after a mean time period of 5.67 months (2-15 m). Mean IOP before removal was 21.4 mm Hg (12-40 mm Hg) and decreased to 11.15 mm Hg (6-20 mm Hg).Conclusions:PGI surgery is an effective procedure for reducing IOP and pressure-lowering therapy. The use of an intraluminal prolene stent impedes hypotony in the early postoperative phase and enables further noninvasive IOP lowering during the postoperative course.
引用
收藏
页码:808 / 814
页数:7
相关论文
共 50 条
  • [21] Ophthalmologic evaluation of patients submitted to drainage implant in refractory glaucoma
    Moreno, Natalia Pimentel
    de Sousa, Luciene Barbosa
    Duarte, Fernanda Bon
    Tessarioli, Joao Guilherme
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2009, 72 (02) : 225 - 230
  • [22] Combined pars plana vitrectomy and Baerveldt glaucoma implant placement for refractory glaucoma
    Campagnoli, Thalmon R.
    Kim, Sung Soo
    Smiddy, William E.
    Gedde, Steve J.
    Budenz, Donald L.
    Parrish, Richard K., II
    Palmberg, Paul F.
    Feuer, William
    Shi, Wei
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2015, 8 (05) : 916 - 921
  • [23] Combined Baerveldt glaucoma drainage implant and trabeculectomy with mitomycin C for refractory glaucoma
    Budenz, DL
    Scott, IU
    Nguyen, QH
    Feuer, W
    Singh, K
    Nicolela, MT
    Bueche, M
    Palmberg, PF
    JOURNAL OF GLAUCOMA, 2002, 11 (05) : 439 - 445
  • [24] Combined pars plana vitrectomy and Baerveldt glaucoma implant placement for refractory glaucoma
    Thalmon R.Campagnoli
    Sung Soo Kim
    William E.Smiddy
    Steve J.Gedde
    Donald L.Budenz
    Richard K.Parrish II
    Paul F.Palmberg
    William Feuer
    Wei Shi
    International Journal of Ophthalmology, 2015, (05) : 916 - 921
  • [25] Two-Year Outcomes of Trabeculectomy and Phacotrabeculectomy in Primary Open Angle Versus Primary Angle Closure Glaucoma
    Winuntamalakul, Yolradee
    Chansangpetch, Sunee
    Ratanawongphaibul, Kitiya
    Itthipanichpong, Rath
    Manassakorn, Anita
    Tantisevi, Visanee
    Rojanapongpun, Prin
    JOURNAL OF GLAUCOMA, 2023, 32 (05) : 374 - 381
  • [26] Surgical Repair of the Extrusion of the Body of a PAUL Implant for Glaucoma
    Milla, Elena
    Izquierdo, Jordi
    Sanchez Dalmau, Bernardo
    CASE REPORTS IN OPHTHALMOLOGY, 2022, 13 (02): : 671 - 677
  • [27] XEN Glaucoma Implant for the Management of Glaucoma in Naive Patients versus Patients with Previous Glaucoma Surgery
    Lewczuk, Katarzyna
    Konopinska, Joanna
    Jablonska, Joanna
    Rudowicz, Jacek
    Laszewicz, Patrycja
    Dmuchowska, Diana Anna
    Mariak, Zofia
    Rekas, Marek
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (19)
  • [28] Comparison of Two Tube-Modification Techniques in Baerveldt Glaucoma Implantation in Refractory Glaucoma
    Petpiroon, Purit
    Vijittrakarnrung, Thanyathorn
    Supakontanasan, Wasu
    Tantraworasin, Apichat
    Suwan, Yanin
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 1689 - 1695
  • [29] Surgical Outcomes of Additional Ahmed Glaucoma Valve Implantation in Refractory Glaucoma
    Ko, Sung Ju
    Hwang, Young Hoon
    Ahn, Sang Il
    Kim, Hwang Ki
    JOURNAL OF GLAUCOMA, 2016, 25 (06) : E620 - E624
  • [30] Impact of mitomycin C on surgical outcomes of PAUL glaucoma implant in neovascular glaucoma: 12-month follow-up results
    Olgun, Ali
    Karapapak, Murat
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2025,