Preparation-based B 1+ mapping in the heart using Bloch-Siegert shifts
被引:0
|作者:
Siuryte, Paulina
[1
]
Tourais, Joao
[1
]
Zhang, Yi
[1
]
Coletti, Chiara
[1
]
van de Steeg-Henzen, Christal
[2
]
Mandija, Stefano
[3
]
Tao, Qian
[1
]
Henningsson, Markus
[4
]
Weingartner, Sebastian
[1
,2
]
机构:
[1] Delft Univ Technol, Dept Imaging Phys, Lorentzweg 1, NL-2628 CJ Delft, Netherlands
[2] HollandPTC, Delft, Netherlands
[3] Univ Med Ctr Utrecht, Dept Radiotherapy, Div Imaging & Oncol, Utrecht, Netherlands
[4] Linkoping Univ, Dept Hlth Med & Caring Sci, Linkoping, Sweden
关键词:
Bloch-Siegert shift;
cardiac imaging;
preparation-based;
B(1)(+)mapping;
ROBUST;
PULSE;
T-1;
D O I:
10.1002/mrm.30232
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Purpose: To develop and evaluate a robust cardiac B(1)(+)mapping sequence at 3 T, using Bloch-Siegert shift (BSS)-based preparations. Methods: A longitudinal magnetization preparation module was designed toencode |B-1(+)|. After magnetization tip-down, off-resonant Fermi pulses, placed sym-metrically around two refocusing pulses, induced BSS, followed by tipping backof the magnetization. Bloch simulations were used to optimize refocusing pulseparameters and to assess the mapping sensitivity. Relaxation-induced B-1(+) errorwas simulated for various T-1/T-2 times. The effective mapping range was determined in phantom experiments, and |B-1(+)| maps were compared to the conventionalBSS method and subadiabatic hyperbolic-secant 8 (HS8) pulse-sensitized method.Cardiac B-1(+) maps were acquired in healthy subjects, and evaluated for repeatability and imaging plane intersection consistency. The technique was modified forthree-dimensional (3D) acquisition of the whole heart in a single breath-hold, andcompared to two-dimensional (2D) acquisition. Results: Simulations indicate that the proposed preparation can be tailored toachieve high mapping sensitivity across various B-1(+) ranges, with maximum sensitivity at the upper B-1(+) range. T-1/T-2 -induced bias did not exceed 5.2%. Experimentallyreproduced B-1(+) sensitization closely matched simulations for B-1(+)>= 0.3B(1,max)(+)(mean difference 0.031 +/- 0.022, compared to 0.018 +/- 0.025 in the HS8-sensitized method),and showed 20-fold reduction in the standard deviation of repeated scans, comparedwith conventional BSS B(1 )(+)mapping, and an equivalent 2-fold reduction comparedwith HS8-sensitization. Robust cardiac B-1(+) map quality was obtained, with an average test-retest variability of 0.027 +/- 0.043 relative to normalized B(1 )(+)magnitude, and plane intersection bias of 0.052 +/- 0.031. 3D acquisitions showed good agreement with 2D scans (mean absolute deviation 0.055 +/- 0.061). Conclusion: BSS-based preparations enable robust and tailorable 2D/3D cardiac B(1)(+)mapping at 3 T in a single breath-hold.