Recent developments in the application of immobilized artificial membrane (IAM) chromatography to drug discovery

被引:3
|
作者
Tsopelas, Fotios [1 ]
Vallianatou, Theodosia [2 ]
Tsantili-Kakoulidou, Anna [3 ]
机构
[1] Natl Tech Univ Athens, Sch Chem Engn, Lab Inorgan & Analyt Chem, Athens, Greece
[2] Uppsala Univ, Dept Pharmaceut Biosci, Uppsala, Sweden
[3] Natl & Kapodistrian Univ Athens, Sch Pharm, Dept Pharmaceut Chem, Athens, Greece
关键词
Immobilized artificial membrane (IAM) chromatography; IAM stationary phases; membrane permeability; drug-membrane interactions; tissue binding; toxicity; ecotoxicity; IAM prediction models; PHOSPHOLIPID STATIONARY PHASES; BLOOD-BRAIN-BARRIER; HUMAN SERUM-ALBUMIN; PARTITION-COEFFICIENTS; LIQUID-CHROMATOGRAPHY; PHOSPHATIDYLCHOLINE COLUMN; POLAR INTERACTIONS; MONOLITHIC COLUMN; EFFICIENCY INDEX; HPLC;
D O I
10.1080/17460441.2024.2374409
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
IntroductionImmobilized artificial membrane (IAM) chromatography is widely used in many aspects of drug discovery. It employs stationary phases, which contain phospholipids combining simulation of biological membranes with rapid measurements.Areas coveredAdvances in IAM stationary phases, chromatographic conditions and the underlying retention mechanism are discussed. The potential of IAM chromatography to model permeability and drug-membrane interactions as well as its use to estimate pharmacokinetic properties and toxicity endpoints including ecotoxicity, is outlined. Efforts to construct models for prediction IAM retention factors are presented.Expert opinionIAM chromatography, as a border case between partitioning and binding, has broadened its application from permeability studies to encompass processes involving tissue binding. Most IAM-based permeability models are hybrid models incorporating additional molecular descriptors, while for the estimation of pharmacokinetic properties and binding to off targets, IAM retention is combined with other biomimetic properties. However, for its integration into routine drug discovery protocols, reliable IAM prediction models implemented in relevant software should be developed, to enable its use in virtual screening and the design of new molecules. Conversely, preparation of new IAM columns with different phospholipids or mixed monomers offers enhanced flexibility and the potential to tailor the conditions according to the target property.
引用
收藏
页码:1087 / 1098
页数:12
相关论文
共 50 条
  • [1] Advances in immobilized artificial membrane (IAM) chromatography for novel drug discovery
    Tsopelas, Fotios
    Vallianatou, Theodosia
    Tsantili-Kakoulidou, Anna
    EXPERT OPINION ON DRUG DISCOVERY, 2016, 11 (05) : 473 - 488
  • [2] Revisiting the application of Immobilized Artificial Membrane (IAM) chromatography to estimate in vivo distribution properties of drug discovery compounds based on the model of marketed drugs
    Valko, Klara
    Rava, Silvia
    Bunally, Shenaz
    Anderson, Scott
    ADMET AND DMPK, 2020, 8 (01): : 78 - 97
  • [3] Prediction of drug absorption based on immobilized artificial membrane (IAM) chromatography separation and calculated molecular descriptors
    Yen, TE
    Agatonovic-Kustrin, S
    Evans, AM
    Nation, RL
    Ryand, J
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 38 (03) : 472 - 478
  • [4] Immobilized Artificial Membrane Chromatography and Its Application in Profiling the Drug Membrane Transport
    Sun Jin
    Zhang Tianhong
    He Zhonggui
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2005, 23 (04) : 378 - 383
  • [5] Immobilized artificial membrane (IAM) chromatography with cyclodextrin-modified mobile phases
    Armstrong, Ariel S.
    Coym, Jason W.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 245
  • [6] Phospholipid-based Immobilized Artificial Membrane (IAM) Chromatography: A Powerful Tool to Model Drug Distribution Processes
    Sobanska, Anna W.
    Brzezinska, Elzbieta
    CURRENT PHARMACEUTICAL DESIGN, 2017, 23 (44) : 6784 - 6794
  • [7] SYNTHESIS OF IMMOBILIZED ARTIFICIAL MEMBRANE (IAM) SURFACES
    PIDGEON, C
    RHEE, DM
    QIU, XX
    ONG, SW
    BERNAL, C
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 205 : 15 - BTEC
  • [8] SYNTHESIS OF IMMOBILIZED ARTIFICIAL MEMBRANE (IAM) SURFACES
    PIDGEON, C
    RHEE, DM
    QIU, XX
    ONG, SW
    BERNAL, C
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 206 : 48 - ANYL
  • [9] Predicting membrane permeability of small molecule drugs using immobilized artificial membrane (IAM) chromatography
    Szczerba, T
    LC GC NORTH AMERICA, 2003, : 50 - 50
  • [10] IMMOBILIZED ARTIFICIAL MEMBRANE (IAM) CHROMATOGRAPHY FOR ANALYSIS OF BILIARY VESICLE-ASSOCIATED PROTEINS
    SECKNUS, R
    YAMASHITA, G
    CORRADINI, SG
    CHERNOSKY, A
    KRIVACIC, K
    HOLZBACH, RT
    GASTROENTEROLOGY, 1995, 108 (04) : A1165 - A1165