Qualitative and quantitative image quality of coronary CT angiography using photon-counting computed tomography: Standard and Ultra-high resolution protocols

被引:6
作者
Vattay, Borbala [1 ]
Boussoussou, Melinda [1 ]
Vecsey-Nagy, Milan [1 ]
Kolossvary, Marton [2 ,3 ]
Juhasz, Denes [1 ]
Kerkovits, Nora [4 ]
Balogh, Hanna [4 ]
Nagy, Norbert [4 ]
Vertes, Miklos [4 ]
Kiss, Mate [5 ]
Kubovje, Aniko [4 ]
Merkely, Bela [1 ]
Horvat, Pal Maurovich [4 ]
Szilveszter, Balint [1 ,6 ]
机构
[1] Semmelweis Univ, Heart & Vasc Ctr, Varosmajor St 68, H-1122 Budapest, Hungary
[2] Gottsegen Natl Cardiovasc Ctr, 29 Haller Utca, H-1096 Budapest, Hungary
[3] Obuda Univ, Univ Res & Innovat Ctr, Physiol Controls Res Ctr, Becsi Ut 96-B, H-1034 Budapest, Hungary
[4] Semmelweis Univ, Med Imaging Ctr, Korany Sandor St 2, H-1082 Budapest, Hungary
[5] Siemens Healthcare GmbH, Forchheim, Germany
[6] 18 Hataror Ut, H-1122 Budapest, Hungary
关键词
Computed Tomography Angiography; Coronary CTA; Coronary Stents; Image Quality;
D O I
10.1016/j.ejrad.2024.111426
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We aimed to identify the optimal reconstruction settings based on qualitative and quantitative image quality parameters on standard and ultra-high resolution (UHR) images using photon-counting CT (PCCT). Method: We analysed 45 patients, 29 with standard and 16 with UHR acquisition, applying both smoother and sharper kernel settings. Coronary CT angiography images were performed on a dual-source PCCT system using standard (0.4/0.6 mm slice thickness, Bv40/Bv44 kernels, QIR levels 0-4) or UHR acquisition (0.2/0.4 mm slice thickness, Bv44/Bv56 kernels, QIR levels 0-4). Qualitative image quality was assessed using a 4-point Likert scale. Image noise (SD), signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated in both the proximal and distal segments. Results: On standard resolution, larger slice thickness resulted in an average increase of 12.5 % in CNR, whereas sharper kernel led to an average 8.7 % decrease in CNR. Highest CNR was measured on 0.6 mm, Bv40, QIR4 images and lowest on 0.4 mm, Bv44, QIR0 images: 25.8 +/- 4.1vs.8.3 +/- 1.6 (p < 0.001). On UHR images, highest CNR was observed on 0.4 mm, Bv40, QIR4 and lowest on 0.2 mm, Bv56 and QIR0 images: 21.5 +/- 3.9vs.3.6 +/- 0.8 (p < 0.001). Highest qualitative image quality was found on images with Bv44 kernel and QIR level 3/4 with both slice thicknesses on standard reconstruction. Additionally, Bv56 with QIR4 on 0.2 mm slice thickness images showed highest subjective image quality. Preserved distal vessel visualization was detected using QIR 2-4, Bv56 and 0.2 mm slice thickness. Conclusions: Photon-counting CT demonstrated high qualitative and quantitative image quality for the assessment of coronaries and stents.
引用
收藏
页数:11
相关论文
共 22 条
[1]   SCCT guidelines for the performance and acquisition of coronary computed tomographic angiography: A report of the society of Cardiovascular Computed Tomography Guidelines Committee Endorsed by the North American Society for Cardiovascular Imaging (NASCI) [J].
Abbara, Suhny ;
Blanke, Philipp ;
Maroules, Christopher D. ;
Cheezum, Michael ;
Choi, Andrew D. ;
Han, B. Kelly ;
Marwan, Mohamed ;
Naoum, Chris ;
Norgaard, Bjarne L. ;
Rubinshtein, Ronen ;
Schoenhagen, Paul ;
Villines, Todd ;
Leipsic, Jonathon .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2016, 10 (06) :435-449
[2]   First In-Human Results of Computed Tomography Angiography for Coronary Stent Assessment With a Spectral Photon Counting Computed Tomography [J].
Boccalini, Sara ;
Si-Mohamed, Salim A. ;
Lacombe, Hugo ;
Diaw, Adja ;
Varasteh, Mohammad ;
Rodesch, Pierre-Antoine ;
Villien, Marjorie ;
Sigovan, Monica ;
Dessouky, Riham ;
Coulon, Philippe ;
Yagil, Yoad ;
Lahoud, Elias ;
Erhard, Klaus ;
Rioufol, Gilles ;
Finet, Gerard ;
Bonnefoy-Cudraz, Eric ;
Bergerot, Cyrille ;
Boussel, Loic ;
Douek, Philippe C. .
INVESTIGATIVE RADIOLOGY, 2022, 57 (04) :212-221
[3]   Spectral Photon-Counting Computed Tomography for Coronary Stent Imaging Evaluation of the Potential Clinical Impact for the Delineation of In-Stent Restenosis [J].
Bratke, Grischa ;
Hickethier, Tilman ;
Bar-Ness, Daniel ;
Bunck, Alexander Christian ;
Maintz, David ;
Pahn, Gregor ;
Coulon, Philippe ;
Si-Mohamed, Salim ;
Douek, Philippe ;
Sigovan, Monica .
INVESTIGATIVE RADIOLOGY, 2020, 55 (02) :61-67
[4]   Stent imaging on a clinical dual-source photon-counting detector CT system-impact of luminal attenuation and sharp kernels on lumen visibility [J].
Decker, Josua A. A. ;
O'Doherty, Jim ;
Schoepf, U. Joseph ;
Todoran, Thomas M. M. ;
Aquino, Gilberto J. J. ;
Brandt, Verena ;
Baruah, Dhiraj ;
Fink, Nicola ;
Zsarnoczay, Emese ;
Flohr, Thomas ;
Schmidt, Bernhard ;
Allmendinger, Thomas ;
Risch, Franka ;
Varga-Szemes, Akos ;
Emrich, Tilman .
EUROPEAN RADIOLOGY, 2023, 33 (04) :2469-2477
[5]   Photon-counting CT review [J].
Flohr, Thomas ;
Petersilka, Martin ;
Henning, Andre ;
Ulzheimer, Stefan ;
Ferda, Jiri ;
Schmidt, Bernhard .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 79 :126-136
[6]   First in-vivo coronary stent imaging with clinical ultra high resolution photon-counting CT [J].
Geering, Ladina ;
Sartoretti, Thomas ;
Mergen, Victor ;
Cundari, Giulia ;
Rusek, Stephane ;
Civaia, Filippo ;
Rossi, Philippe ;
Wildberger, Joachim E. ;
Templin, Christian ;
Manka, Robert ;
Eberhard, Matthias ;
Alkadhi, Hatem .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2023, 17 (03) :233-235
[7]   Virtual monochromatic images for coronary artery imaging with a spectral photon-counting CT in comparison to dual-layer CT systems: a phantom and a preliminary human study [J].
Greffier, Joel ;
Si-Mohamed, Salim A. ;
Lacombe, Hugo ;
Labour, Joey ;
Djabli, Djamel ;
Boccalini, Sara ;
Varasteh, Mohammad ;
Villien, Marjorie ;
Yagil, Yoad ;
Erhard, Klaus ;
Boussel, Loic ;
Beregi, Jean-Paul ;
Douek, Philippe C. .
EUROPEAN RADIOLOGY, 2023, 33 (08) :5476-5488
[8]   The effect of four-phasic versus three-phasic contrast media injection protocols on extravasation rate in coronary CT angiography: a randomized controlled trial [J].
Karady, Julia ;
Panajotu, Alexisz ;
Kolossvary, Marton ;
Szilveszter, Balint ;
Jermendy, Adam L. ;
Bartykowszki, Andrea ;
Karolyi, Mihaly ;
Celeng, Csilla ;
Merkely, Bela ;
Maurovich-Horvat, Pal .
EUROPEAN RADIOLOGY, 2017, 27 (11) :4538-4543
[9]   2019 ESC Guidelines for the diagnosis and management of chronic coronary syndromes The Task Force for the diagnosis and management of chronic coronary syndromes of the European Society of Cardiology (ESC) [J].
Knuuti, Juhani ;
Wijns, William ;
Saraste, Antti ;
Capodanno, Davide ;
Barbato, Emanuele ;
Funck-Brentano, Christian ;
Prescott, Eva ;
Storey, Robert F. ;
Deaton, Christi ;
Cuisset, Thomas ;
Agewall, Stefan ;
Dickstein, Kenneth ;
Edvardsen, Thor ;
Escaned, Javier ;
Gersh, Bernard J. ;
Svitil, Pavel ;
Gilard, Martine ;
Hasdai, David ;
Hatala, Robert ;
Mahfoud, Felix ;
Masip, Josep ;
Muneretto, Claudio ;
Valgimigli, Marco ;
Achenbach, Stephan ;
Bax, Jeroen J. ;
Neumann, Franz-Josef ;
Sechtem, Udo ;
Banning, Adrian Paul ;
Bonaros, Nikolaos ;
Bueno, Hector ;
Bugiardini, Raffaele ;
Chieffo, Alaide ;
Crea, Filippo ;
Czerny, Martin ;
Delgado, Victoria ;
Dendale, Paul .
EUROPEAN HEART JOURNAL, 2020, 41 (03) :407-477
[10]   Coronary artery stenosis quantification in patients with dense calcifications using ultra-high-resolution photon-counting-detector computed tomography [J].
Koons, Emily K. ;
Rajiah, Prabhakar Shantha ;
Thorne, Jamison E. ;
Weber, Nikkole M. ;
Kasten, Holly J. ;
Shanblatt, Elisabeth R. ;
Mccollough, Cynthia H. ;
Leng, Shuai .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2024, 18 (01) :56-61