An analytical model for axially compressed circular concrete-filled steel tubular (CFST) short columns with varied confinement factors

被引:0
|
作者
Chang, Yanjun [1 ,2 ,3 ]
Rong, Enchao [1 ]
Wang, Xiangyu [1 ]
Jiang, Hui [1 ]
Teng, Xiaodan [1 ,2 ,3 ]
机构
[1] Guangxi Univ, Coll Civil Engn & Architecture, Nanning 530004, Peoples R China
[2] Guangxi Univ, Guangxi Key Lab Disaster Prevent & Struct Safety, Nanning 530004, Peoples R China
[3] Guangxi Univ, Key Lab Disaster Prevent & Struct Safety, Minist Educ, Nanning 530004, Peoples R China
关键词
Concrete -filled steel tube; Hoop -axial strain model; Analytical model; Confinement factor; Post -peak behavior; STRESS-STRAIN MODEL; HIGH-STRENGTH STEEL; STUB COLUMNS; EXPERIMENTAL BEHAVIOR; TUBE COLUMNS; THEORETICAL-MODEL; PLAIN CONCRETE; DESIGN; HOLLOW; DUCTILITY;
D O I
10.1016/j.istruc.2024.106802
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Accurate evaluation of the load-strain behavior of axially compressed concrete-filled steel tube (CFST) short columns is pivotal for engineering structures, and depends on precise prediction of the hoop-axial strain response. This study introduces a two-stage hoop-axial strain relationship that incorporates the initial Poisson's ratio and elastic limit to account for the initial linearity of concrete, and a reduction coefficient to take into account the effect of concrete strength on lateral deformation properties, based on a widely used hoop-axial equation. Experimental validation across a definite concrete strength range of 28 MPa to 125.3 MPa reveals improved predictions for the dilation rate of CFST columns subjected to axial compression, particularly for those columns fabricated with high-strength concrete (> 100 MPa). Subsequently, an analytical model consisting of the proposed two-stage strain relationship, a confined concrete model with inflection-point strain and residual strength, and the biaxial stress-strain relationship of steel tube is then established to estimate the compressive behavior of circular CFST short columns. Experimental verification over a range of confinements (confinement factor from 0.289 to 2.138) demonstrates the ability of the proposed analytical model to accurately capture the load-strain curves of circular CFST short columns, especially the post-peak behavior of those with confinement factors less than 1. The performance of the established analytical model in assessing the axial load-carrying capacity of circular CFST stub columns is investigated using a database assembled from available studies.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Nonlinear analysis of axially loaded circular concrete-filled stainless steel tubular short columns
    Patel, Vipulkumar Ishvarbhai
    Liang, Qing Quan
    Hadi, Muhammad N. S.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2014, 101 : 9 - 18
  • [2] Numerical modeling of axially loaded circular concrete-filled double-skin steel tubular short columns incorporating a new concrete confinement model
    Ahmed, Mizan
    Ci, Junchang
    Yan, Xi-Feng
    Lin, Siqi
    Chen, Shicai
    STRUCTURES, 2021, 30 : 611 - 627
  • [3] Numerical simulation of axially loaded circular concrete-filled steel tubular short columns with localized corrosion
    Zeng, Wenyan
    Ayough, Pouria
    Wang, Yu-Hang
    Elchalakani, Mohamed
    ENGINEERING STRUCTURES, 2024, 312
  • [4] Compressive strength of axially loaded circular hollow centrifugal concrete-filled steel tubular short columns
    Zhao, Yan-Gang
    Yan, Xi-Feng
    Lin, Siqi
    ENGINEERING STRUCTURES, 2019, 201
  • [5] A numerical model with varying passive confinement for circular and elliptical concrete-filled steel tubular columns
    Lacuesta, C. D.
    Romero, M. L.
    Lapuebla-Ferri, A.
    Adam, J. M.
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON ADVANCES IN STEEL-CONCRETE COMPOSITE STRUCTURES (ASCCS 2018), 2018, : 409 - 417
  • [6] Creep analysis comparison of circular axially compressed concrete-filled steel tubular members
    School of Civil Engineering and Architecture, Beijing Jiaotong University, Beijing 100044, China
    Zongguo Gonglu Xuebao, 2007, 2 (83-86):
  • [7] Numerical analysis of axially loaded circular high strength concrete-filled double steel tubular short columns
    Ahmed, Mizan
    Liang, Qing Quan
    Patel, Vipulkumar Ishvarbhai
    Hadi, Muhammad N. S.
    THIN-WALLED STRUCTURES, 2019, 138 : 105 - 116
  • [8] Behaviour of axially loaded circular concrete-filled bimetallic stainless-carbon steel tubular short columns
    Patel, Vipulkumar Ishvarbhai
    Hassanein, M. F.
    Thai, Huu-Tai
    Al Abadi, Haider
    Paton-Cole, Vidal
    ENGINEERING STRUCTURES, 2017, 147 : 583 - 597
  • [9] Compressive strength of axially loaded circular concrete-filled double-skin steel tubular short columns
    Yan, Xi-Feng
    Zhao, Yan-Gang
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 170
  • [10] Confinement effectiveness of circular concrete-filled steel tubular columns under axial compression
    Wei, Yang
    Jiang, Cheng
    Wu, Yu-Fei
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 158 : 15 - 27