Semi-automated protocol to quantify and characterize fluorescent three-dimensional vascular images

被引:0
|
作者
Xie, Danny F. [1 ,2 ]
Crouzet, Christian [1 ,2 ]
Lopresti, Krystal [1 ,2 ]
Wang, Yuke [1 ,2 ]
Robinson, Christopher [1 ,2 ]
Jones, William [1 ]
Muqolli, Fjolla [1 ]
Fang, Chuo [3 ]
Cribbs, David H. [4 ]
Fisher, Mark [1 ,3 ,4 ,5 ]
Choi, Bernard [1 ,2 ]
机构
[1] Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92612 USA
[2] Univ Calif Irvine, Dept Biomed Engn, Irvine, CA 92612 USA
[3] Univ Calif Irvine, Dept Neurol, Irvine, CA USA
[4] Univ Calif Irvine, Inst Memory Impairments & Neurol Disorders, Irvine, CA USA
[5] Univ Calif Irvine, Dept Pathol & Lab Med, Irvine, CA USA
来源
PLOS ONE | 2024年 / 19卷 / 05期
基金
美国国家卫生研究院;
关键词
3D VISUALIZATION; TISSUE; IDISCO; MICROBLEEDS;
D O I
10.1371/journal.pone.0289109
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The microvasculature facilitates gas exchange, provides nutrients to cells, and regulates blood flow in response to stimuli. Vascular abnormalities are an indicator of pathology for various conditions, such as compromised vessel integrity in small vessel disease and angiogenesis in tumors. Traditional immunohistochemistry enables the visualization of tissue cross-sections containing exogenously labeled vasculature. Although this approach can be utilized to quantify vascular changes within small fields of view, it is not a practical way to study the vasculature on the scale of whole organs. Three-dimensional (3D) imaging presents a more appropriate method to visualize the vascular architecture in tissue. Here we describe the complete protocol that we use to characterize the vasculature of different organs in mice encompassing the methods to fluorescently label vessels, optically clear tissue, collect 3D vascular images, and quantify these vascular images with a semi-automated approach. To validate the automated segmentation of vascular images, one user manually segmented one hundred random regions of interest across different vascular images. The automated segmentation results had an average sensitivity of 83 +/- 11% and an average specificity of 91 +/- 6% when compared to manual segmentation. Applying this procedure of image analysis presents a method to reliably quantify and characterize vascular networks in a timely fashion. This procedure is also applicable to other methods of tissue clearing and vascular labels that generate 3D images of microvasculature.
引用
收藏
页数:14
相关论文
共 50 条
  • [11] Pilot feasibility study of a semi-automated three-dimensional scoring system for cervical dystonia
    Oyama, Genko
    Nakamura, Takuto
    Sekimoto, Satoko
    Shimo, Yasushi
    Hattori, Nobutaka
    Kajimoto, Hiroyuki
    NEUROLOGY, 2019, 92 (15)
  • [12] Semi-automated Detection and Quantification of Aortic Atheromas from Three-Dimensional Transesophageal Echocardiography
    Piazzese, Concetta
    Tsang, Wendy
    Sotaquira, Miguel
    Lang, Roberto M.
    Caiani, Enrico G.
    2013 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2013, 40 : 13 - 16
  • [13] Pilot feasibility study of a semi-automated three-dimensional scoring system for cervical dystonia
    Nakamura, Takuto
    Sekimoto, Satoko
    Oyama, Genko
    Shimo, Yasushi
    Hattori, Nobutaka
    Kajimoto, Hiroyuki
    PLOS ONE, 2019, 14 (08):
  • [14] (Semi-)automated quantitative analysis of three-dimensional intravascular ultrasound images
    Dijkstra, J
    Koning, G
    Tuinenburg, JC
    Oemrawsingh, PV
    Reiber, JHC
    EUROPEAN HEART JOURNAL, 2000, 21 : 506 - 506
  • [15] A new semi-automated method for fetal volume measurements with three-dimensional ultrasound: preliminary results
    Smeets, Nicol A. C.
    Dvinskikh, Natallia A.
    Winkens, Bjorn
    Oei, S. Guid
    PRENATAL DIAGNOSIS, 2012, 32 (08) : 770 - 776
  • [16] Assessment of resynchronisation therapy based on dynamic three-dimensional echocardiography and semi-automated border detection
    Szili-Torok, T
    Krenning, BJ
    Voormolen, MM
    Theuns, DAMJ
    Jordaens, LJ
    Ten Cate, F
    Roelandt, JRTC
    EUROPEAN HEART JOURNAL, 2003, 24 : 395 - 395
  • [17] A three-dimensional finite element model from computed tomography data: a semi-automated method
    Cattaneo, PM
    Dalstra, M
    Frich, LH
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2001, 215 (H2) : 203 - 213
  • [18] Semi-automated analysis of high-resolution aerial images to quantify docks in glacial lakes
    Beck, Marcus W.
    Vondracek, Bruce
    Hatch, Lorin K.
    Vinje, Jason
    ISPRS JOURNAL OF PHOTOGRAMMETRY AND REMOTE SENSING, 2013, 81 : 60 - 69
  • [19] Three-dimensional semi-automated volumetric assessment of the pulp space of teeth following regenerative dental procedures
    Heeresh Shetty
    Shishir Shetty
    Adesh Kakade
    Aditya Shetty
    Mohmed Isaqali Karobari
    Ajinkya M. Pawar
    Anand Marya
    Artak Heboyan
    Adith Venugopal
    The Hanh Nguyen
    Dinesh Rokaya
    Scientific Reports, 11
  • [20] Semi-automated fabrication of customized ocular prosthesis with three-dimensional printing and sublimation transfer printing technology
    Ko, JaeSang
    Kim, So Hyun
    Baek, Seung Woon
    Chae, Min Kyung
    Yoon, Jin Sook
    SCIENTIFIC REPORTS, 2019, 9 (1)