Large axial-flow fans are widely used in many fields. The inlet box is an integral part of large axial-flow fans, and a welldesigned inlet box could effectively improve fan efficiency. However, the inlet box structure is complicated, and the existing inlet box design method severely depends on the design experience. In this study, we propose a structure optimization design system based on a surrogate model technique for researching the critical structure parameters of the inlet box and accomplishing aerodynamic performance optimization. As for this expensive optimization problem, the design system contains twice optimization procedures by using the Response Surface Methodology (RSM) with the orthogonal design method. The optimization object is an existing large axial-flow fan. The optimization objective is the total pressure efficiency of the fan, and the total pressure rise is the restriction condition. We generate eighteen different inlet boxes connect with the same impeller and outlet pipe by the orthogonal design method and calculated fan aerodynamic performance by CFX software. After the first optimization, we find the key structural parameters by the sensitivity analysis and the reselect variables total of 25 cases are adopted in a further RSM optimal process. The ultimate surrogate model estimates the fan with the optimal inlet box has a better aerodynamic characteristic and a 6.7% total pressure efficiency rise. Finally, we compare the aerodynamic characteristics of the ultimate design fan and the initial fan by CFD simulation. The numerical results show that: the total pressure efficiency is 6.5% higher than that of the initial impeller, and the pressure rise is 3% higher than that of the initial impeller. The result demonstrates that some most critical parameters of the inlet box structure decide the aerodynamic performance, and the inlet box optimization effectively increases the fan efficiency in the meanwhile.
引用
收藏
页数:9
相关论文
共 15 条
  • [1] Development of a cleaning fan for a rice combine harvester using computational fluid dynamics and response surface methodology to optimise outlet airflow distribution
    Chai, Xiaoyu
    Xu, Lizhang
    Sun, Yixin
    Liang, Zhenwei
    Lu, En
    Li, Yaoming
    [J]. BIOSYSTEMS ENGINEERING, 2020, 192 : 232 - 244
  • [2] Hu Shengli, 1995, Journal of Engineering Thermophysics, V16, P60
  • [3] Effect of inlet box on performance of axial flow fans
    Li J.
    Tian H.
    Yuan X.
    [J]. Frontiers of Energy and Power Engineering in China, 2008, 2 (4): : 390 - 394
  • [4] Aerodynamic optimization of through-flow design model of a high by-pass transonic aero-engine fan using genetic algorithm
    Kor, Orcun
    Acarer, Sercan
    Ozkol, Unver
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2018, 232 (03) : 211 - 224
  • [5] Aerodynamic design and optimization of a high-loaded axial fan stage using a curvature control method
    Li, Jieling
    Chen, Huanlong
    Liu, Yang
    Wang, Junli
    Yang, Xianqing
    [J]. JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2019, 33 (08) : 3871 - 3883
  • [6] An optimal design of axial-flow fan blades by the machining method and an artificial neural network
    Lin, BJ
    Hung, CI
    Tang, EJ
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2002, 216 (03) : 367 - 376
  • [7] Liu F., 2013, Electric Power Construction, P15
  • [8] Lu yong, 1998, Fluid Machinery., V27, P8
  • [9] Luo Yong., 1998, Fluid Machinery, V26, P14
  • [10] Neise W, 1986, P 1 EUR S AIR COND R, P165