Rapid detection of explosives in collected dust using ion mobility spectrometry

被引:3
|
作者
Choi, He-Ryun [1 ]
Son, Chae Eun [1 ]
Choi, Sung -Seen [1 ]
机构
[1] Sejong Univ, Dept Chem, 209 Neungdong Ro, Seoul 05006, South Korea
关键词
Ion mobility spectrometry; Explosives; Dust; Collection filter; Cyclone; INDOOR DUST; HOUSE-DUST; DESORPTION; ADSORPTION;
D O I
10.1016/j.microc.2024.110882
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Vapor and particulate matter from explosives can be adsorbed onto dust, enabling their detection in security and military applications. In this study, model explosive-adsorbed dust specimens were prepared using four types of dust from two inorganic substances [silica (SL) and clay (CL)] and two organic materials [sawdust (SD) and cotton fabric (CF)]. Three explosives, namely 2,4,6-trinitrotoluene (TNT), 1,3,5-trinitro-1,3,5-triazacyclohexane (RDX), and pentaerythritol tetranitrate (PETN), were investigated, along with two different collection filters of poly(tetrafluoroethylene) (PTFE) and lens cleansing paper (LCP). The dust was sprayed in a hood and collected using a cyclone collector. The explosive components present in the dust were rapidly detected using ion mobility spectrometry (IMS). The adsorption efficiencies of TNT, RDX, and PETN onto dust were 36 - 97, 45 - 76, and 37 - 90 %, respectively, and the values of the inorganic dusts were higher than those of the organic dusts. The dust collection rate ranged from 5 to 15 %, and decreased in the order of CL > CF > SL = SD. The factors influencing rapid explosive detection were the intrinsic vapor pressure of the explosive, interactions between the dust and the explosive, thermal conductivities of the dusts and collection filters, and structure of the collection filter. Due to the low vapor pressure of RDX, this explosive was detected later than TNT and PETN. In most cases, detection was more rapid when using the LCP than when using the PTFE because of the thicker and woven structure of the PTFE filter. The detection limits achieved using the LCP (0.049 - 1.17 mu g) were lower than those of the PTFE (0.67 - 10.05 mu g). When the PTFE was used, the detection limits for the organic dusts were lower than those for the inorganic dusts. Notably, the detection limits of the explosives adsorbed onto dust were significantly higher than those of the pure explosives.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Tandem Ion Mobility Spectrometry for the Detection of Traces of Explosives in Cargo at Concentrations of Parts Per Quadrillion
    Amo-Gonzalez, Mario
    Perez, Sergio
    Delgado, Rafael
    Arranz, Gonzalo
    Carnicero, Irene
    ANALYTICAL CHEMISTRY, 2019, 91 (21) : 14009 - 14018
  • [42] Identity confirmation of drugs and explosives in ion mobility spectrometry using a secondary drift gas
    Kanu, Abu B.
    Hill, Herbert H., Jr.
    TALANTA, 2007, 73 (04) : 692 - 699
  • [43] Examination of some organic explosives by ion mobility spectrometry (IMS)
    Koyuncu, H
    Seven, E
    Çalimli, A
    TURKISH JOURNAL OF CHEMISTRY, 2005, 29 (03) : 255 - 264
  • [44] An on-site inspection system for explosives in a container using dust collection through a vent cover and ion mobility spectrometric detection
    Choi, He-Ryun
    Choi, Sung-Seen
    ANALYTICAL METHODS, 2024, 16 (33) : 5702 - 5709
  • [45] Explorative study for the rapid detection of adulterated surimi using gas chromatography-ion mobility spectrometry
    Chen, Jingyi
    Tang, Haiqing
    Wang, Mengyun
    Wei, Huamao
    Ou, Changrong
    FOOD CHEMISTRY, 2024, 439
  • [46] Ion mobility spectrometry fingerprints: A rapid detection technology for adulteration of sesame oil
    Zhang, Liangxiao
    Shuai, Qian
    Li, Peiwu
    Zhang, Qi
    Ma, Fei
    Zhang, Wen
    Ding, Xiaoxia
    FOOD CHEMISTRY, 2016, 192 : 60 - 66
  • [47] Rapid-screening detection of acetildenafils, sildenafils and avanafil by ion mobility spectrometry
    Mans, Daniel J.
    Callahan, Rebecca J.
    Dunn, Jamie D.
    Gryniewicz-Ruzicka, Connie M.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 75 : 153 - 157
  • [48] Rapid authentication of sesame oil using ion mobility spectrometry and chemometrics
    Jun Jiang
    Xinjing Dou
    Liangxiao Zhang
    Jin Mao
    Li Yu
    Fei Ma
    Peiwu Li
    Oil Crop Science, 2020, 5 (04) : 161 - 165
  • [49] Detection of emissions from surfaces using ion mobility spectrometry
    Wolfgang Vautz
    Jörg Ingo Baumbach
    Erik Uhde
    Analytical and Bioanalytical Chemistry, 2006, 384 : 980 - 986
  • [50] CONTINUOUS DETECTION OF HYDRAZINE AND MONOMETHYLHYDRAZINE USING ION MOBILITY SPECTROMETRY
    LEASURE, CS
    EICEMAN, GA
    ANALYTICAL CHEMISTRY, 1985, 57 (09) : 1890 - 1894