Rapid detection of explosives in collected dust using ion mobility spectrometry

被引:3
|
作者
Choi, He-Ryun [1 ]
Son, Chae Eun [1 ]
Choi, Sung -Seen [1 ]
机构
[1] Sejong Univ, Dept Chem, 209 Neungdong Ro, Seoul 05006, South Korea
关键词
Ion mobility spectrometry; Explosives; Dust; Collection filter; Cyclone; INDOOR DUST; HOUSE-DUST; DESORPTION; ADSORPTION;
D O I
10.1016/j.microc.2024.110882
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Vapor and particulate matter from explosives can be adsorbed onto dust, enabling their detection in security and military applications. In this study, model explosive-adsorbed dust specimens were prepared using four types of dust from two inorganic substances [silica (SL) and clay (CL)] and two organic materials [sawdust (SD) and cotton fabric (CF)]. Three explosives, namely 2,4,6-trinitrotoluene (TNT), 1,3,5-trinitro-1,3,5-triazacyclohexane (RDX), and pentaerythritol tetranitrate (PETN), were investigated, along with two different collection filters of poly(tetrafluoroethylene) (PTFE) and lens cleansing paper (LCP). The dust was sprayed in a hood and collected using a cyclone collector. The explosive components present in the dust were rapidly detected using ion mobility spectrometry (IMS). The adsorption efficiencies of TNT, RDX, and PETN onto dust were 36 - 97, 45 - 76, and 37 - 90 %, respectively, and the values of the inorganic dusts were higher than those of the organic dusts. The dust collection rate ranged from 5 to 15 %, and decreased in the order of CL > CF > SL = SD. The factors influencing rapid explosive detection were the intrinsic vapor pressure of the explosive, interactions between the dust and the explosive, thermal conductivities of the dusts and collection filters, and structure of the collection filter. Due to the low vapor pressure of RDX, this explosive was detected later than TNT and PETN. In most cases, detection was more rapid when using the LCP than when using the PTFE because of the thicker and woven structure of the PTFE filter. The detection limits achieved using the LCP (0.049 - 1.17 mu g) were lower than those of the PTFE (0.67 - 10.05 mu g). When the PTFE was used, the detection limits for the organic dusts were lower than those for the inorganic dusts. Notably, the detection limits of the explosives adsorbed onto dust were significantly higher than those of the pure explosives.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Analysis of explosives using differential mobility spectrometry
    Pavlacka, Martin
    Bajerova, Petra
    Kortankova, Katerina
    Blaha, Jiri
    Zastera, Michal
    Mazl, Roman
    Ventura, Karel
    INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2016, 19 (01) : 31 - 39
  • [32] Detection of explosives by differential mobility spectrometry and GC DMS
    Eiceman, GA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 230 : U330 - U330
  • [33] Explorative study for the rapid detection of Fritillaria using gas chromatography-ion mobility spectrometry
    Dai, Yuping
    Liu, Shanshuo
    Yang, Li
    He, Ye
    Guo, Xiao
    Ma, Yang
    Li, Shunxiang
    Huang, Dan
    FRONTIERS IN NUTRITION, 2024, 11
  • [34] Detection of axillary perspiration metabolites using ion mobility spectrometry coupled to rapid gas chromatography
    Wolfgang Vautz
    Luzia Seifert
    Marziyeh Mohammadi
    Isabelle A. G. Klinkenberg
    Sascha Liedtke
    Analytical and Bioanalytical Chemistry, 2020, 412 : 223 - 232
  • [35] Detection of axillary perspiration metabolites using ion mobility spectrometry coupled to rapid gas chromatography
    Vautz, Wolfgang
    Seifert, Luzia
    Mohammadi, Marziyeh
    Klinkenberg, Isabelle A. G.
    Liedtke, Sascha
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (01) : 223 - 232
  • [36] Hydrocarbon detection using laser ion mobility spectrometry
    Oberhuettinger, C.
    Langmeier, A.
    Oberpriller, H.
    Kessler, M.
    Goebel, J.
    Mueller, G.
    INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2009, 12 (01) : 23 - 32
  • [37] Using ion mobility spectrometry for detection of trace pesticides
    Moskowitz, Lauren
    Martin, Grace Anne
    Yu, Liren
    Sharma, Parijat
    Demoranville, Leonard
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 252
  • [38] Evaluation of false positive responses by mass spectrometry and ion mobility spectrometry for the detection of trace explosives in complex samples
    Crawford, C. L.
    Hill, H. H., Jr.
    ANALYTICA CHIMICA ACTA, 2013, 795 : 36 - 43
  • [39] Analysis of explosives using corona discharge ionization combined with ion mobility spectrometry-mass spectrometry
    Lee, Jihyeon
    Park, Sehwan
    Cho, Soo Gyeong
    Goh, Eun Mee
    Lee, Sungman
    Koh, Sung-Suk
    Kim, Jeongkwon
    TALANTA, 2014, 120 : 64 - 70
  • [40] Analytical method for the estimation of transfer and detection efficiencies of solid state explosives using ion mobility spectrometry and smear matrix
    Choi, Sung-Seen
    Son, Chae Eun
    ANALYTICAL METHODS, 2017, 9 (17) : 2505 - 2510