Rapid detection of explosives in collected dust using ion mobility spectrometry

被引:3
|
作者
Choi, He-Ryun [1 ]
Son, Chae Eun [1 ]
Choi, Sung -Seen [1 ]
机构
[1] Sejong Univ, Dept Chem, 209 Neungdong Ro, Seoul 05006, South Korea
关键词
Ion mobility spectrometry; Explosives; Dust; Collection filter; Cyclone; INDOOR DUST; HOUSE-DUST; DESORPTION; ADSORPTION;
D O I
10.1016/j.microc.2024.110882
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Vapor and particulate matter from explosives can be adsorbed onto dust, enabling their detection in security and military applications. In this study, model explosive-adsorbed dust specimens were prepared using four types of dust from two inorganic substances [silica (SL) and clay (CL)] and two organic materials [sawdust (SD) and cotton fabric (CF)]. Three explosives, namely 2,4,6-trinitrotoluene (TNT), 1,3,5-trinitro-1,3,5-triazacyclohexane (RDX), and pentaerythritol tetranitrate (PETN), were investigated, along with two different collection filters of poly(tetrafluoroethylene) (PTFE) and lens cleansing paper (LCP). The dust was sprayed in a hood and collected using a cyclone collector. The explosive components present in the dust were rapidly detected using ion mobility spectrometry (IMS). The adsorption efficiencies of TNT, RDX, and PETN onto dust were 36 - 97, 45 - 76, and 37 - 90 %, respectively, and the values of the inorganic dusts were higher than those of the organic dusts. The dust collection rate ranged from 5 to 15 %, and decreased in the order of CL > CF > SL = SD. The factors influencing rapid explosive detection were the intrinsic vapor pressure of the explosive, interactions between the dust and the explosive, thermal conductivities of the dusts and collection filters, and structure of the collection filter. Due to the low vapor pressure of RDX, this explosive was detected later than TNT and PETN. In most cases, detection was more rapid when using the LCP than when using the PTFE because of the thicker and woven structure of the PTFE filter. The detection limits achieved using the LCP (0.049 - 1.17 mu g) were lower than those of the PTFE (0.67 - 10.05 mu g). When the PTFE was used, the detection limits for the organic dusts were lower than those for the inorganic dusts. Notably, the detection limits of the explosives adsorbed onto dust were significantly higher than those of the pure explosives.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Drugs and explosives identify differentiation in ion mobility spectrometry
    Kanu, A. Bakarr
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 257
  • [22] Ion mobility spectrometry: a tool to detect narcotics and explosives
    Fuche, Christine
    Deseille, Julie
    ACTUALITE CHIMIQUE, 2010, (342-43): : 91 - 95
  • [23] Parameters of laser ionization of explosives for ion mobility spectrometry
    Akmalov, Artem E.
    Chistyakov, Alexander A.
    Kotkovskii, Gennadii E.
    Kostarev, Vitalii A.
    COUNTERTERRORISM, CRIME FIGHTING, FORENSICS, AND SURVEILLANCE TECHNOLOGIES II, 2018, 10802
  • [24] Analysis of explosives using electrospray ionization/ion mobility spectrometry (ESI/IMS)
    Asbury, GR
    Klasmeier, J
    Hill, HH
    TALANTA, 2000, 50 (06) : 1291 - 1298
  • [25] Laser desorption with corona discharge ion mobility spectrometry for direct surface detection of explosives
    Sabo, M.
    Malaskova, M.
    Matejcik, S.
    ANALYST, 2014, 139 (20) : 5112 - 5117
  • [26] Dopant-Assisted Negative Photoionization Ion Mobility Spectrometry for Sensitive Detection of Explosives
    Cheng, Shasha
    Dou, Jian
    Wang, Weiguo
    Chen, Chuang
    Hua, Lei
    Zhou, Qinghua
    Hou, Keyong
    Li, Jinghua
    Li, Haiyang
    ANALYTICAL CHEMISTRY, 2013, 85 (01) : 319 - 326
  • [27] Optimized thermal desorption for improved sensitivity in trace explosives detection by ion mobility spectrometry
    Najarro, Marcela
    Morris, Melissa E. Davila
    Staymates, Matthew E.
    Fletcher, Robert
    Gillen, Greg
    ANALYST, 2012, 137 (11) : 2614 - 2622
  • [28] Detection of explosives using negative ion mobility spectrometry in air based on dopant-assisted thermal ionization
    Shahraki, Hassan
    Tabrizchi, Mahmoud
    Farrokhpor, Hossein
    JOURNAL OF HAZARDOUS MATERIALS, 2018, 357 : 1 - 9
  • [29] DEVELOPMENT OF AN ION MOBILITY SPECTROMETER FOR DETECTION OF EXPLOSIVES
    Sivakumar, N.
    Joseph, M.
    Manoravi, P.
    Rao, P. R. Vasudeva
    Raj, Baldev
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2013, 41 (01) : 96 - 108
  • [30] Modular Ion Mobility Spectrometer for Explosives Detection Using Corona Ionization
    Roscioli, Kristyn M.
    Davis, Eric
    Siems, William F.
    Mariano, Adrian
    Su, Wansheng
    Guharay, Samar K.
    Hill, Herbert H., Jr.
    ANALYTICAL CHEMISTRY, 2011, 83 (15) : 5965 - 5971