Research on the countermeasures of the single-phase-to-earth faults in flexibly grounded distribution networks

被引:2
|
作者
Ren, Xiaofeng [1 ,2 ]
Bai, Yunhao [1 ]
Dai, Yongzheng [1 ]
Liang, Rui [1 ]
Gao, Hailong [2 ]
Su, Lingdong [2 ]
Zhang, Xiao [2 ]
Kong, Lingchang [3 ]
Zhang, Peng [1 ]
机构
[1] China Univ Min & Technol, Sch Elect Engn, Xuzhou 221116, Jiangsu, Peoples R China
[2] State Grid Xuzhou Power Supply Co, Xuzhou 221005, Jiangsu, Peoples R China
[3] Kehua Data Co Ltd, Xiamen 361000, Fujian, Peoples R China
关键词
Flexible grounding; Distribution network; Fault feeder detection; Fault disposal; LINE SELECTION;
D O I
10.1016/j.aej.2024.04.020
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In a neutral, flexible, grounded distribution network, the phenomenon that a single-phase ground fault with high impedance connected in parallel with a low resistance can result in a relatively lower zero-sequence current flowing through the faulty feeder. This zero-sequence current can make it a challenge to use zero-sequence protection schemes to accurately identify and effectively protect the faulty feeder. In terms of the aforementioned challenge, based on the zero-sequence equivalent circuit of a single-phase-to-earth fault, this paper conducts an investigation on the phase difference between the zero-sequence current and the non-fault phase line voltage at power frequency in flexible grounding distribution network with different grounded conditions, both before and after the introduction of a parallel low-resistor connection. Subsequently, a criterion for selecting the faulty feeder is developed based on the observed phase difference characteristics following the implementation of the parallel low-resistor connection. Furthermore, a disposal strategy for single-phase-to-earth faults is formulated, which takes fault resistance estimation into account. To validate the proposed method, a simulation model of a flexible grounding distribution network is implemented with PSCAD/EMTDC. The effectiveness and reliability of this method in multiple scenes, including the initial fault conditions, sampling frequency, and distributed generation (DG), are proved through simulation results.
引用
收藏
页码:68 / 79
页数:12
相关论文
共 50 条
  • [31] Location of Single Phase to Ground Faults in Distribution Networks Based on Synchronous Transients Energy Analysis
    Wang, Xuewen
    Zhang, Hengxu
    Shi, Fang
    Wu, Qiuwei
    Terzija, Vladimir
    Xie, Wei
    Fang, Chen
    IEEE TRANSACTIONS ON SMART GRID, 2020, 11 (01) : 774 - 785
  • [32] Characteristics of earth faults in electrical distribution networks with high impedance earthing
    Hanninen, S
    Lehtonen, M
    ELECTRIC POWER SYSTEMS RESEARCH, 1998, 44 (03) : 155 - 161
  • [33] Faulty Phase Recognition Method for Single-Line-to-Ground Fault in Resonant Grounded Distribution Networks
    Ma, Mingwen
    Wang, Wen
    Wang, Faliang
    Ren, Xingqiang
    Wang, Zhen
    2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2018, : 351 - 357
  • [34] RESEARCH ON ADAPTIVE TRIPPING FOR SINGLE PHASE EARTH FAULT IN NEUTRAL POINT NON-EFFECTIVELY GROUNDED SYSTEM
    Xue, Yongduan
    Zhang, Qiufeng
    Wang, Zhenheng
    Xu, Bingyin
    Sun, Bo
    2012 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2012,
  • [35] Estimating distance to transient and restriking earth faults in high-impedance grounded, ring-operated distribution networks using current ratios
    Treider, Thomas
    Hoidalen, Hans Kristian
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 224
  • [36] Research on a method of fault line selection for single-phase earth fault in ineffectively grounded power systems
    Lu, Gai-Feng
    Hua, Yu
    Jin, Xiao-Bing
    Ren, Zhi-Qiang
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (12): : 44 - 49
  • [37] Implementation and laboratory verification of method utilizing phase and neutral quantities for detection and location of low-current earth faults in resonant grounded networks
    Treider, Thomas
    Hoidalen, Hans Kristian
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2023, 17 (24) : 5446 - 5457
  • [38] Research on detecting single-phase-to-ground faulted feeder in resonant grounded power distribution system
    Chen, Kui
    Tang, Yi
    Liu, Changjiang
    Dong, Haibo
    Gaodianya Jishu/High Voltage Engineering, 2007, 33 (01): : 61 - 65
  • [39] Transmission line fault location for single-phase-to-earth fault on non-direct-ground neutral system
    Zhang, QC
    Zhang, Y
    Song, WN
    Fang, DZ
    IEEE TRANSACTIONS ON POWER DELIVERY, 1998, 13 (04) : 1086 - 1092
  • [40] Countermeasures for reduction of screen currents due to cross country faults in MV cable distribution networks
    Cerretti, A.
    D'Orazio, L.
    Gatta, F. M.
    Geri, A.
    Lauria, S.
    Maccioni, M.
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 214