Rapid, on-site quantitative determination of mycotoxins in grains using a multiple time-resolved fluorescent microsphere immunochromatographic test strip

被引:13
|
作者
Liang, Junfa [2 ]
Li, Xuewei [1 ]
Huang, Bin [3 ]
Pan, Yupeng [1 ]
Zhuang, Zile [1 ]
Ye, Qiuxiong [2 ]
Peng, Cheng [2 ]
Deng, Huangyi [4 ]
Yi, Yunting [2 ]
Zhang, Binbin [2 ]
Chen, Peiyi [2 ]
Chen, Xuncai [1 ]
机构
[1] Southern Med Univ, Sch Forens Med, Dept Forens Toxicol, Guangzhou 510515, Peoples R China
[2] Guangzhou Inst Food Inspect, Guangzhou 511400, Peoples R China
[3] Shenzhen Lvshiyuan Biotechnol Co Ltd, Shenzhen 518100, Peoples R China
[4] Guangdong Inst Food Inspect, Guangzhou 510000, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Mycotoxins; On -site quantitative detection; Multiple detection; Time resolved fluorescent microspheres; Immunochromatography test strip; Grains; QUANTUM-DOT NANOBEADS; LIQUID-CHROMATOGRAPHY; ZEARALENONE; OCHRATOXIN; AFLATOXINS; B-1; IMMUNOSENSOR; CITRININ; M-1;
D O I
10.1016/j.bios.2024.116357
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The label probe plays a crucial role in enhancing the sensitivity of lateral flow immunoassays. However, conventional fluorescent microspheres (FMs) have limitations due to their short fluorescence lifetime, susceptibility to background fluorescence interference, and inability to facilitate multi-component detection. In this study, carboxylate-modified Eu(III)-chelate-doped polystyrene nanobeads were employed as label probes to construct a multiple time-resolved fluorescent microsphere-based immunochromatographic test strip (TRFM-ICTS). This novel TRFM-ICTS facilitated rapid on-site quantitative detection of three mycotoxins in grains: Aflatoxin B1 (AFB1), Zearalenone (ZEN), and Deoxynivalenol (DON). The limit of detection (LOD) for AFB1, ZEN, and DON were found to be 0.03 ng/g, 0.11 ng/g, and 0.81 ng/g, respectively. Furthermore, the TRFM-ICTS demonstrated a wide detection range for AFB1 (0.05-8.1 ng/g), ZEN (0.125-25 ng/g), and DON (1.0-234 ng/g), while maintaining excellent selectivity. Notably, the test strip exhibited remarkable stability, retaining its detection capability even after storage at 4 degrees C for over one year. Importantly, the detection of these mycotoxins relied solely on simple manual operations, and with a portable reader, on-site detection could be accomplished within 20 min. This TRFM-ICTS presents a promising solution for sensitive on-site mycotoxin detection, suitable for practical application in various settings due to its sensitivity, accuracy, simplicity, and portability.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] A time-resolved fluorescent microsphere-lateral flow immunoassay strip assay with image visual analysis for quantitative detection of Helicobacter pylori in saliva
    Wang, Yilu
    Chen, Qiming
    Wang, Yingying
    Tu, Fangmin
    Chen, Xiaodi
    Li, Junhai
    Liu, Zhanmin
    TALANTA, 2023, 256
  • [42] Time-resolved fluorescent lateral flow strip for easy and rapid quality control of edible oil
    Wu, Qian
    Yao, Li
    Qin, Panzhu
    Xu, Jianguo
    Sun, Xun
    Yao, Bangben
    Ren, Fei
    Chen, Wei
    FOOD CHEMISTRY, 2021, 357 (357)
  • [43] Development of a colloidal gold-based immunochromatographic test strip for the rapid, on-site detection of Pseudomonas aeruginosa in clinical samples
    Wang, Yan
    Dou, Hengli
    Chen, Kuixiang
    Zhang, Hua
    Hu, Chengjin
    SCANDINAVIAN JOURNAL OF INFECTIOUS DISEASES, 2011, 43 (05) : 329 - 338
  • [44] Rapid, On-Site, Ultrasensitive Melamine Quantitation Method for Protein Beverages Using Time-Resolved Fluorescence Detection Paper
    Li, Guanghua
    Wang, Du
    Zhou, Aijun
    Sun, Yimin
    Zhang, Qi
    Poapolathep, Amnart
    Zhang, Li
    Fan, Zhiyong
    Zhang, Zhaowei
    Li, Peiwu
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2018, 66 (22) : 5671 - 5676
  • [45] Rapid evaluation of hepatocellular carcinoma by detecting plasma exosomes with time-resolved fluorescence immunochromatographic test strips
    Li, Jiaming
    Su, Jianfen
    Li, Minghui
    Wu, Yaofen
    Chen, Huiqiang
    Fu, Xihua
    Yao, Hongliang
    Chen, Jinping
    Liu, Yuntao
    Zan, Jie
    MICROCHIMICA ACTA, 2025, 192 (01)
  • [46] Rapid, on-site and quantitative paper-based immunoassay platform for concurrent determination of pesticide residues and mycotoxins
    Tang, Xiaoqian
    Zhang, Qi
    Zhang, Zhaowei
    Ding, Xiaoxia
    Jiang, Jun
    Zhang, Wen
    Li, Peiwu
    ANALYTICA CHIMICA ACTA, 2019, 1078 : 142 - 150
  • [47] A Europium Nanosphere-Based Time-Resolved Fluorescent Immunochromatographic Assay for the Rapid Screening of 4,4'-Dinitrocarbanilide: Aiming at Improving Strip Method Performance
    Zou, Ming
    Yin, Yongkang
    Guo, Liuchuan
    Zhang, Qidi
    Li, Jinyan
    Zhang, Hong
    Song, Qian
    Li, Zhaojie
    Wang, Li
    Ao, Xiang
    Liang, Xiao
    BIOSENSORS-BASEL, 2023, 13 (05):
  • [48] Portable, Rapid, and Sensitive Time-Resolved Fluorescence Immunochromatography for On-Site Detection of Dexamethasone in Milk and Pork
    Li, Xiangmei
    Chen, Xiaomin
    Wu, Jinxiao
    Liu, Zhiwei
    Wang, Jin
    Song, Cuiping
    Zhao, Sijun
    Lei, Hongtao
    Sun, Yuanming
    FOODS, 2021, 10 (06)
  • [49] Development and evaluation of time-resolved fluorescent immunochromatographic assay for quantitative detection of SARS-CoV-2 spike antigen
    Xu, Buzhou
    Tang, Hao
    Weng, Yiming
    Jones, Valerie Sloane
    Luo, Shuhong
    Cho, Chih Yun
    Lin, Yongping
    Fang, Jianmin
    Song, Xuedong
    Huang, Ruo-Pan
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2022, 36 (07)
  • [50] Development of a time-resolved fluorescent immunochromatographic assay for the quantitative detection of cardiovascular disease by MPO and Lp-PLA2
    Zhang, Shuang-Zhe
    Zheng, Jian-Shu
    Luo, Shu-Hong
    Xu, Bu-Zhuo
    Liu, Xiao-Yan
    Zhang, Ben-Yue
    Tang, Hao
    Weng, Yi-Ming
    Yin, Xiao-Mao
    Song, Xue-Dong
    Huang, Ruo-Pan
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2024, 17 (03): : 32 - 40