Ex vivo simulation of cardiopulmonary bypass with human blood for hemocompatibility testing

被引:5
作者
Teligui, Leylah [1 ,2 ]
Dalmayrac, Emilie [1 ]
Corbeau, Jean-Jacques [3 ]
Bouquet, Emmanuelle [1 ]
Godon, Alban [4 ]
Denomme, Anne-Sophie [5 ]
Binuani, Partrice [1 ]
Verron, Laurence [1 ]
Boer, Christa [2 ]
Baufreton, Christophe [1 ]
机构
[1] Univ Hosp Angers, Dept Cardiac & Thorac Surg, Angers, France
[2] Vrije Univ Amsterdam, Med Ctr, Inst Cardiovasc Res, Dept Anesthesiol, Amsterdam, Netherlands
[3] Univ Hosp Angers, Dept Anesthesiol, Angers, France
[4] Univ Hosp Angers, Lab Hematol, Angers, France
[5] Univ Hosp Angers, Immunol Lab, Angers, France
来源
PERFUSION-UK | 2016年 / 31卷 / 05期
关键词
cardiopulmonary bypass; hemostasis; biosurface; coating; heparin; EXTRACORPOREAL-CIRCULATION; HEPARIN; COAGULATION; COMPLEMENT; ACTIVATION; BIOCOMPATIBILITY; BIOMATERIAL; GENERATION; COATINGS; CIRCUITS;
D O I
10.1177/0267659115599454
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Object: Experimental circuits for biomaterial surface testing are frequently limited by the tested blood volume, composition of the circuit, flow conditions and the use of animal blood. This report describes an ex vivo set-up for simulated cardiopulmonary bypass with human blood perfusion. We investigated the clinical generalizability of the observed effects on hematological and metabolic parameters and the hemocompatibility of the system. Methods: The simulated cardiopulmonary bypass circuit consisted of a heparin-coated tubing system connected to an oxygenator and a venous reservoir. Normothermic flow of blood obtained from healthy donors was maintained at 2.4 L/min/m(2) by a roller pump. Heparin was dosed to obtain a target activated clotting time (ACT) 500 s. Blood was drawn at baseline and 0, 10, 60 and 120 minutes following the initiation of blood flow to determine hematological and metabolic parameters and the hemocompatibility of the extracorporeal system. Data were analyzed using repeated measures ANOVA. Results: Two hours of blood perfusion resulted in a small, but clinically unimportant reduction in hematocrit, whereas hemoglobin levels and red blood cell, platelet and leukocyte counts remained stable. There was a significant increase in ACT throughout the experiment. While pO(2) levels and the pH remained unaltered during the experiment, pCO(2) values decreased from 51 6 mmHg at T0 to 41 +/- 3 mmHg at T120 (p<0.001). Simulated cardiopulmonary bypass induced a two-fold increase in C3a (p=0.001) while tissue factor was decreased from 44 +/- 14 pg/mL at T0 to 38 +/- 13 pg/mL at T120 (p=0.009). Levels of CD40L, prothrombin fragment 1+2, -thromboglobulin and factor VIIa remained stable over time. Conclusion: The ex vivo set-up for simulated cardiopulmonary bypass mimicked the clinical cardiosurgical setting. Exposure of fresh donor blood to the extracorporeal circuit showed a good hemocompatibility, indicated by maintained hematological parameters and a mild immune response.
引用
收藏
页码:376 / 383
页数:8
相关论文
共 23 条
  • [1] Measures to control blood activation during assisted circulation
    Baufreton, C
    Kirsch, M
    Loisance, DY
    [J]. ANNALS OF THORACIC SURGERY, 1998, 66 (05) : 1837 - 1844
  • [2] De Somer Filip, 2007, J Extra Corpor Technol, V39, P285
  • [3] Tubing loops as a model for cardiopulmonary bypass circuits: Both the biomaterial and the blood-gas phase interfaces induce complement activation in an in vitro model
    Gong, J
    Larsson, R
    Ekdahl, KN
    Mollnes, TE
    Nilsson, U
    Nilsson, B
    [J]. JOURNAL OF CLINICAL IMMUNOLOGY, 1996, 16 (04) : 222 - 229
  • [4] Active or passive bio-coating: does it matters in extracorporeal circulation?
    Jacobs, S.
    De Somer, F.
    Vandenplas, G.
    Van Belleghem, Y.
    Taeymans, Y.
    Van Nooten, G.
    [J]. PERFUSION-UK, 2011, 26 (06): : 496 - 502
  • [5] In vitro assessment of blood compatibility: Residual and dynamic markers of cellular activation
    Johnson, Greg
    Curry, Benjamin
    Cahalan, Linda
    Prater, Roni
    Beeler, Michael
    Gartner, Mark
    Biggerstaff, John
    Cahalan, Patrick
    [J]. JOURNAL OF BIOMATERIALS APPLICATIONS, 2013, 27 (08) : 925 - 936
  • [6] Comparison of porcine and human coagulation by thrombelastometry
    Kessler, Ulf
    Grau, Tamar
    Gronchi, Fabrizio
    Berger, Steffen
    Brandt, Sebastian
    Bracht, Hendrik
    Marcucci, Carlo
    Zachariou, Zacharias
    Jakob, Stephan M.
    [J]. THROMBOSIS RESEARCH, 2011, 128 (05) : 477 - 482
  • [7] The effects of Carmeda bioactive surface on human blood components during simulated extracorporeal circulation
    Korn, RL
    Fisher, CA
    Livingston, ER
    Stenach, N
    Fishman, SJ
    Jeevanandam, V
    Addonizio, VP
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 111 (05) : 1073 - 1084
  • [8] A NEW NON-THROMBOGENIC SURFACE PREPARED BY SELECTIVE COVALENT BINDING OF HEPARIN VIA A MODIFIED REDUCING TERMINAL RESIDUE
    LARM, O
    LARSSON, R
    OLSSON, P
    [J]. BIOMATERIALS MEDICAL DEVICES AND ARTIFICIAL ORGANS, 1983, 11 (2-3): : 161 - 173
  • [9] Complement and biocompatibility
    Mollnes, TE
    [J]. VOX SANGUINIS, 1998, 74 : 303 - 307
  • [10] Early Heparin Administration Attenuates Tissue Factor-Mediated Thrombin Generation During Simulated Cardiopulmonary Bypass
    Morizumi, Sei
    Hiramatsu, Yuji
    Matsuzaki, Kanji
    Goto, Yukinobu
    Sato, Shoko
    Abe, Masakazu
    Kato, Hideyuki
    Matsubara, Muneaki
    Sakakibara, Yuzuru
    [J]. JOURNAL OF CARDIAC SURGERY, 2014, 29 (01) : 35 - 40