Biomechanical Analysis of Adjacent Segments after Spinal Fusion Surgery Using a Geometrically Parametric Patient-Specific Finite Element Model

被引:0
作者
Wang, Yuming [1 ]
Shen, Qianyi [2 ]
Liang, Chang [2 ]
Shen, Yanzhu [1 ]
Tang, Xiangsheng [1 ]
Yi, Ping [1 ]
机构
[1] China Japan Friendship Hosp, Dept Spine Surg, Beijing, Peoples R China
[2] Beijing Univ Chem Technol, Coll Mech & Elect Engn, Beijing, Peoples R China
来源
JOVE-JOURNAL OF VISUALIZED EXPERIMENTS | 2024年 / 203期
关键词
LUMBAR INTERBODY FUSION; INTRADISCAL PRESSURE; SCREW FIXATION; RISK-FACTORS; FACET JOINT; INSTRUMENTATION; STABILITY; PROVIDES; DISC;
D O I
10.3791/66247
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study aimed to perform a mechanical analysis of adjacent segments after spinal fusion surgery using a geometrically parametric patient-specific finite element model to elucidate the mechanism of adjacent segment degeneration (ASD), thereby providing theoretical evidence for early disease prevention. Fourteen parameters based on patient-specific spinal geometry were extracted from a patient's preoperative computed tomography (CT) scan, and the relative positions of each spinal segment were determined using the image match method. A preoperative patient-specific model of the spine was established through the above method. The postoperative model after L4 -L5 posterior lumbar interbody fusion (PLIF) surgery was constructed using the same method except that the lamina and intervertebral disc were removed, and a cage, 4 pedicle screws, and 2 connecting rods were inserted. Range of motion (ROM) and stress changes were determined by comparing the values of each anatomical structure between the preoperative and postoperative models. The overall ROM of the lumbar spine decreased after fusion, while the ROM, stress in the facet joints, and stress in the intervertebral disc of adjacent segments all increased. An analysis of the stress distribution in the annulus fibrosus, nucleus pulposus, and facet joints also showed that not only was the maximum stress in these tissues elevated, but the areas of moderate -to -high stress were also expanded. During torsion, the stress in the facet joints and annulus fibrosus of the proximal adjacent segment (L3L4) increased to a larger extent than that in the distal adjacent segment (L5 -S1). While fusion surgery causes an overall restriction of motion in the lumbar spine, it also causes more load sharing by the adjacent segments to compensate for the fused segment, thus increasing the risk of ASD. The proximal adjacent segment is more prone to
引用
收藏
页数:20
相关论文
共 40 条
  • [1] Bilateral pedicle screw fixation provides superior biomechanical stability in transforaminal lumbar interbody fusion: a finite element study
    Ambati, Divya V.
    Wright, Edward K., Jr.
    Lehman, Ronald A., Jr.
    Kang, Daniel G.
    Wagner, Scott C.
    Dmitriev, Anton E.
    [J]. SPINE JOURNAL, 2015, 15 (08) : 1812 - 1822
  • [2] Effect of disc degeneration on the mechanical behavior of the human lumbar spine: a probabilistic finite element study
    Bashkuev, Maxim
    Reitmaier, Sandra
    Schmidt, Hendrik
    [J]. SPINE JOURNAL, 2018, 18 (10) : 1910 - 1920
  • [3] NEW METHOD TO ANALYZE MECHANICAL BEHAVIOR OF SKELETAL PARTS
    BREKELMA.WA
    SLOOFF, TJJH
    POORT, HW
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1972, 43 (05): : 301 - &
  • [4] Chen W J, 2001, Spine (Phila Pa 1976), V26, pE519, DOI 10.1097/00007632-200111150-00024
  • [5] The effect of spinal destabilization and instrumentation on lumbar intradiscal pressure an in vitro biomechanical analysis
    Cunningham, BW
    Kotani, Y
    McNulty, PS
    Cappuccino, A
    McAfee, PC
    [J]. SPINE, 1997, 22 (22) : 2655 - 2663
  • [6] Transforaminal lumbar interbody fusion (TLIF) versus posterior lumbar interbody fusion (PLIF) in lumbar spondylolisthesis: a systematic review and meta-analysis
    de Kunder, Suzanne L.
    van Kuijk, Sander M. J.
    Rijkers, Kim
    Caelers, Inge J. M. H.
    van Hemert, Wouter L. W.
    de Bie, Rob A.
    van Santbrink, Henk
    [J]. SPINE JOURNAL, 2017, 17 (11) : 1712 - 1721
  • [7] Comparison of eight published static finite element models of the intact lumbar spine: Predictive power of models improves when combined together
    Dreischarf, M.
    Zander, T.
    Shirazi-Adl, A.
    Puttlitz, C. M.
    Adam, C. J.
    Chen, C. S.
    Goel, V. K.
    Kiapour, A.
    Kim, Y. H.
    Labus, K. M.
    Little, J. P.
    Park, W. M.
    Wang, Y. H.
    Wilke, H. J.
    Rohlmann, A.
    Schmidt, H.
    [J]. JOURNAL OF BIOMECHANICS, 2014, 47 (08) : 1757 - 1766
  • [8] Subject-specific biomechanics of trunk: musculoskeletal scaling, internal loads and intradiscal pressure estimation
    Ghezelbash, F.
    Shirazi-Adl, A.
    Arjmand, N.
    El-Ouaaid, Z.
    Plamondon, A.
    [J]. BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2016, 15 (06) : 1699 - 1712
  • [9] Moment-rotation responses of the human lumbosacral spinal column
    Guan, Yabo
    Yoganandan, Narayan
    Moore, Jason
    Pintar, Frank A.
    Zhang, Jiangyue
    Maiman, Dennis J.
    Laud, Purushottam
    [J]. JOURNAL OF BIOMECHANICS, 2007, 40 (09) : 1975 - 1980
  • [10] Surgical treatment of degenerative spondylolisthesis
    Guigui, P.
    Ferrero, E.
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (01) : S11 - S20